← Back
Primarily 1 family with 1 store or office
118-02 180 STREET
QUEENS · St. Albans · BIN 4269037
💬 Discuss this project
1901Year Built
2Stories
S1Building Class
R3AZoning
1,387 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Primarily 1 family with 1 store or office · 3,536 sf lot · 0.39 FAR built · Flood zone X
Locations of Work
ElectricalGeneral
Roof2p · 1 filing · 11 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TRINITY SOLAR LLC201/06/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ACA ASSOCIATES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRINITY SOLAR LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BITOPI CONSULTANTS LLC7036201/06/2026
Building Lifecycle
All (10)Filed (2)Permit Issued (1)Signed Off (1)Violation (2)Special Inspection (4)
02/25/2026
Signed off — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01173135-I1
02/19/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
KAMRUL AHSAN
02/19/2026
Special inspection requirement — Energy Code Compliance Inspections
Ayracon Almaraz
02/19/2026
Special inspection requirement — Final
Ayracon Almaraz
02/19/2026
Special inspection requirement — Air barrier - visual inspection
Ayracon Almaraz
01/06/2026
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01173135-P1
11/17/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2025
Permit issued — Solar
Q01173135-I1-SL
02/03/2025
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01173135-I1
03/07/2017
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offTRINITY SOLAR LLC02/07/2025
1 project · most recent 01/20/2025
FiledStatusContractorScope
01/20/2025CompleteREDLINE ELECTRIC INC—
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
02/19/2026Fire-Resistant Penetrations and JointsKAMRUL AHSANspecial
02/19/2026Energy Code Compliance InspectionsAyracon Almarazprogress
02/19/2026FinalAyracon Almarazprogress
02/19/2026Air barrier - visual inspectionAyracon Almarazenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026Q01173135-I1Request digital key ↗
08/17/2026Q01173135-P1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/26/2026Q01173135-I1Open ↗
08/26/2026Q01173135-I1Open ↗
08/26/2026Q01173135-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026Q01173135-I1Open ↗
08/17/2026Q01173135-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q01173135-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/17/2026Q01173135-P1Open ↗
08/17/2026Q01173135-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01173135-I1Open ↗