← Back
Predominantly retail with other uses
118-20 QUEENS BOULEVARD
QUEENS · BIN 4079998
💬 Discuss this project
1931Year Built
3Stories
K4Building Class
C4-4DZoning
3,618 sfGross Floor Area
3Units
Rent Stabilized0 Open Violations
Predominantly retail with other uses · Owner of record: A.M. QUEENS, LLC · 1,800 sf lot · 2.01 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
VCASA CONSTRUCTION607/08/2026
INSPARISK LLC403/22/2026
A.M. QUEENS, LLC103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARQUITECTURA VARELA410/20/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
VCASA CONSTRUCTION INCGeneral Contractor407/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BUTTERFIELD & O'CONNOR4189210/20/2022
Building Lifecycle
All (25)Filed (4)Permit Issued (2)Signed Off (2)Violation (11)Special Inspection (6)
01/19/2023
Signed off — Alteration
repointing and window lintel replacement as per plan. no change in use, egress or occupancy with this application.
Q00769234-I1
01/18/2023
Signed off — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33 OF THE 2014 CODE.
Q00750527-I1
10/24/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
BRIAN T. O'CONNOR
10/24/2022
Special inspection requirement — Masonry
BRIAN T. O'CONNOR
10/24/2022
Special inspection requirement — Final
Vicente Varela
10/20/2022
Filed — Alteration
repointing and window lintel replacement as per plan. no change in use, egress or occupancy with this application.
Q00769234-P1
10/18/2022
Special inspection requirement — Masonry
BRIAN T. O'CONNOR
10/18/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
BRIAN T. O'CONNOR
10/18/2022
Special inspection requirement — Final
Vicente Varela
07/26/2022
Permit issued — General Construction
Q00769234-I1-GC
07/20/2022
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33 OF THE 2014 CODE.
Q00750527-P1
07/19/2022
Filed — Alteration
repointing and window lintel replacement as per plan. no change in use, egress or occupancy with this application.
Q00769234-I1
06/13/2022
Permit issued — Sidewalk Shed
Q00750527-I1-SH
06/10/2022
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33 OF THE 2014 CODE.
Q00750527-I1
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/01/2016
Violation issued (ECB, closed)
Boilers
03/01/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/07/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offVCASA CONSTRUCTION INC07/26/2022
DOB NOWSidewalk ShedSigned-offVCASA CONSTRUCTION INC06/13/2022
BISEQISSUEDSUPER VENUS CONSTRUCTION01/23/2012
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
10/24/2022Structural Stability – Alterations of existing buildingsBRIAN T. O'CONNORspecial
10/24/2022MasonryBRIAN T. O'CONNORspecial
10/24/2022FinalVicente Varelaprogress
10/18/2022MasonryBRIAN T. O'CONNORspecial
10/18/2022Structural Stability – Alterations of existing buildingsBRIAN T. O'CONNORspecial
10/18/2022FinalVicente Varelaprogress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/26/2026Q00769234-I1Request digital key ↗
08/26/2026Q00769234-P1Request digital key ↗
08/26/2026Q00750527-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION1
01/24/2012420525079Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
11/21/2013420525079Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
01/20/2012420525079Open ↗
▸Seals & Professional Certifications14
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/26/2026Q00769234-I1Open ↗
08/26/2026Q00769234-P1Open ↗
08/26/2026Q00750527-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/24/2026Q00769234-I1Open ↗
08/24/2026Q00769234-I1Open ↗
08/22/2026Q00769234-P1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
01/24/2012420525079Open ↗
01/20/2012420525079Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/24/2026Q00769234-I1Open ↗
08/22/2026Q00769234-P1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
01/20/2012420525079Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/24/2012420525079Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/26/2026Q00769234-P1Open ↗
08/26/2026Q00769234-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
11/21/2013420525079Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
01/20/2012420525079Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
01/20/2012420525079Open ↗