← Back
Three families
1190 EAST 233 STREET
BRONX · Eastchester-Edenwald-Baychester · BIN 2066172
💬 Discuss this project
1967Year Built
3Stories
C0Building Class
R5Zoning
2,280 sfGross Floor Area
3Units
1 Open Violation ▸
Three families · 2,520 sf lot · 0.9 FAR built · Flood zone X
Locations of Work
ElectricalPlumbing
Roof3p · 1 filing · 13 docs
Basement1p · 1 filing · 4 docs
Sub-Basement3p · 1 filing · 4 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/19/2023$920K—— → —$404/sf building
01/12/2023$607K—— → —$266/sf building
07/10/2019$585K—— → —$257/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR208/26/2025
MAX DISLA ARCHITECT111/22/2019
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CAPE PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281208/26/2025
Building Lifecycle
All (19)Filed (3)Permit Issued (2)Signed Off (1)Violation (3)Special Inspection (10)
09/15/2025
Signed off — Alteration
Installation of solar panels, rooftop, railed, grid-tied, 12 modules, 4.92 KW
X01089806-I1
09/10/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
09/10/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
09/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
09/10/2025
Special inspection requirement — Final
Mina Makar
09/10/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
08/26/2025
Filed — Alteration
Installation of solar panels, rooftop, railed, grid-tied, 12 modules, 4.92 KW
X01089806-P1
08/25/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
08/25/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
08/25/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
08/25/2025
Special inspection requirement — Final
Mina Makar
08/25/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
08/05/2024
Permit issued — Solar
X01089806-I1-SL
08/02/2024
Filed — Alteration
Installation of solar panels, rooftop, railed, grid-tied, 12 modules, 4.92 KW
X01089806-I1
12/07/2019
Permit issued — Plumbing
X00269364-I1-PL
11/22/2019
Filed — Alteration
INSTALL NEW BOILER AND HOT WATER HEATER AND REPLACE EXISTING BOILER AND HOT WATER HEATER. NO CHANGE IN USE, EGRESS OR OCCUPANCY
X00269364-I1
08/08/2018
Violation issued (HPD, closed)
B
08/08/2018
Violation issued (HPD, closed)
B
11/19/2010
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offMOMENTUM SOLAR08/05/2024
DOB NOWPlumbingPermit IssuedCAPE PLUMBING INC12/07/2019
1 project · most recent 11/22/2019
Gas
FiledStatusContractorScope
11/22/2019Permit IssuedCAPE PLUMBING INCGas
1 project · most recent 11/14/2024
FiledStatusContractorScope
11/14/2024CompleteISLAND ELECTRIC CORP—
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
09/10/2025Air barrier - visual inspectionMina Makarenergy_progress
09/10/2025Structural Stability – Alterations of existing buildingsMina Makarspecial
09/10/2025Fire-Resistant Penetrations and JointsMina Makarspecial
09/10/2025FinalMina Makarprogress
09/10/2025Energy Code Compliance InspectionsMina Makarprogress
08/25/2025Fire-Resistant Penetrations and JointsMina Makarspecial
08/25/2025Structural Stability – Alterations of existing buildingsMina Makarspecial
08/25/2025Energy Code Compliance InspectionsMina Makarprogress
08/25/2025FinalMina Makarprogress
08/25/2025Air barrier - visual inspectionMina Makarenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch2
08/21/2026X01089806-P1Request digital key ↗
08/21/2026X01089806-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/26/2026X00269364-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026X01089806-P1Open ↗
09/01/2026X01089806-P1Open ↗
08/25/2026X01089806-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026X01089806-I1Open ↗
08/13/2026X00269364-I1Open ↗
08/13/2026X01089806-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026X01089806-P1Open ↗
08/25/2026X01089806-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWTenant Protection Plan1
08/13/2026X00269364-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/21/2026X01089806-I1Open ↗
08/13/2026X00269364-I1Open ↗
08/13/2026X01089806-P1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01089806-I1Open ↗