← Back
Walk-up apt, over six families with stores
1193 NOSTRAND AVENUE
BROOKLYN · BIN 3107259
💬 Discuss this project
1931Year Built
3Stories
C7Building Class
R6Zoning
7,596 sfGross Floor Area
10Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Walk-up apt, over six families with stores · Owner of record: 1193 NOSTRAND REALTY LLC · 2,000 sf lot · 3.8 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Floor 541p · 1 filing · 20 docs
Floor 438p · 1 filing · 20 docs
Floor 340p · 1 filing · 20 docs
Floor 240p · 1 filing · 20 docs
Floor 141p · 1 filing · 20 docs
Cellar42p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OWNERS REP507/08/2026
ROGERS BUILDERS & DEVEL3407/08/2026
1193 NOSTRAND REALTY LLC203/22/2026
ROGERS DEVELOPERS GRP403/22/2026
ROGERS CONSTRUCTION LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/30/2022$1.3M—— → —$171/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AE DESIGN SOLUTION403/21/2026
ADVANCED BUILDERS SERVICES2003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ROGERS DEVELOPERS GRP LLCGeneral Contractor1307/08/2026
CORE SCAFFOLD SYSTEMS INC.General Contractor407/08/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
PRIME PIPING & HEATING INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
REGIONAL TESTING CORP.394803/12/2024
Building Lifecycle
All (97)Filed (12)Permit Issued (9)Signed Off (7)Violation (7)Inspection (8)Objection (24)Special Inspection (30)
05/05/2026
Violation issued (HPD, closed)
A
11/20/2025
Violation issued (HPD, closed)
I
06/10/2025
Violation issued (HPD, closed)
A
03/18/2024
Signed off — Alteration CO
2 STORY VERTICAL/HORIZONTAL ADDITION TO AN EXISTING 3 STORY BRICK BUILDING
B00769263-S1
03/18/2024
Special inspection requirement — Structural Steel - Details
Paul Raymond
03/18/2024
Special inspection requirement — Structural Steel - Welding
Paul Raymond
03/18/2024
Special inspection requirement — Post-installed Anchors
Paul Raymond
03/18/2024
Special inspection requirement — Final
Paul Raymond
03/18/2024
Special inspection requirement — Concrete - Cast-In-Place
Paul Raymond
03/18/2024
Special inspection requirement — Structural Steel - High Strength Bolting
Paul Raymond
03/18/2024
Special inspection requirement — Structural Cold-Formed Steel
Paul Raymond
03/18/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Paul Raymond
03/12/2024
Filed — Alteration CO
2 STORY VERTICAL/HORIZONTAL ADDITION TO AN EXISTING 3 STORY BRICK BUILDING
B00769263-P5
03/11/2024
Special inspection requirement — Structural Steel - High Strength Bolting
Paul Raymond
03/11/2024
Special inspection requirement — Concrete - Cast-In-Place
Paul Raymond
03/11/2024
Special inspection requirement — Structural Steel - Welding
Paul Raymond
03/11/2024
Special inspection requirement — Final
Paul Raymond
03/11/2024
Special inspection requirement — Structural Steel - Details
Paul Raymond
03/11/2024
Special inspection requirement — Structural Cold-Formed Steel
Paul Raymond
03/11/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Paul Raymond
03/11/2024
Special inspection requirement — Post-installed Anchors
Paul Raymond
01/31/2024
Signed off — Alteration CO
2 STORY VERTICAL/HORIZONTAL ADDITION TO AN EXISTING 3 STORY BRICK BUILDING
B00769263-S2
01/26/2024
Special inspection requirement — Energy Code Compliance Inspections
Paul Raymond
01/26/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Paul Raymond
01/26/2024
Special inspection requirement — Sprinkler Systems
Paul Raymond
01/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
01/25/2024
Signed off — Alteration CO
2 STORY VERTICAL/HORIZONTAL ADDITION TO AN EXISTING 3 STORY BRICK BUILDING
B00769263-S3
01/22/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/18/2024
Filed — Alteration CO
2 STORY VERTICAL/HORIZONTAL ADDITION TO AN EXISTING 3 STORY BRICK BUILDING
B00769263-P4
01/18/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Paul Raymond
01/18/2024
Special inspection requirement — Sprinkler Systems
Paul Raymond
01/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Paul Raymond
01/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
01/11/2024
Special inspection requirement — Maintenance information
Paul Raymond
01/11/2024
Special inspection requirement — Interior lighting power
Paul Raymond
01/11/2024
Special inspection requirement — Fenestration air leakage
Paul Raymond
01/11/2024
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Paul Raymond
01/11/2024
Special inspection requirement — Insulation placement and R values
Paul Raymond
01/11/2024
Special inspection requirement — Masonry
Paul Raymond
01/10/2024
Permit issued — Mechanical Systems
B00769263-S3-MS
01/04/2024
Signed off — Alteration
Construction fence filed in conjunction with alt-co application #B00769263-I1
B00798224-I1
01/04/2024
Signed off — Alteration CO
2 STORY VERTICAL/HORIZONTAL ADDITION TO AN EXISTING 3 STORY BRICK BUILDING
B00769263-S4
01/04/2024
Objection resolved — Addressed
12/27/2023
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
12/26/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
12/20/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
12/13/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00880542-I1
12/13/2023
Signed off — Alteration
B00879732-I1
11/28/2023
Objection raised — Scope
11/27/2023
Filed — Alteration CO
2 STORY VERTICAL/HORIZONTAL ADDITION TO AN EXISTING 3 STORY BRICK BUILDING
B00769263-P2
09/19/2023
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
09/13/2023
Violation issued (ECB, closed)
Construction
09/11/2023
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
09/05/2023
Violation issued (ECB, closed)
Construction
09/05/2023
Violation issued (ECB, closed)
Construction
07/21/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/21/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/07/2023
Violation issued (ECB, closed)
Site Safety
05/30/2023
Permit issued — Supported Scaffold
B00880542-I1-SF
05/26/2023
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00880542-I1
Latest 60 of 97 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offROGERS DEVELOPERS GRP LLC01/10/2024
DOB NOWSupported ScaffoldSigned-offCORE SCAFFOLD SYSTEMS INC05/30/2023
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC05/26/2023
DOB NOWSprinklersSigned-offPRIME PIPING & HEATING IN04/27/2023
DOB NOWPlumbingSigned-offA M B MECHANICAL INC04/27/2023
DOB NOWFoundationSigned-offROGERS DEVELOPERS GRP LLC03/20/2023
DOB NOWStructuralPermit IssuedROGERS DEVELOPERS GRP LLC03/20/2023
DOB NOWGeneral ConstructionPermit IssuedROGERS DEVELOPERS GRP LLC03/16/2023
DOB NOWConstruction FenceSigned-offROGERS DEVELOPERS GRP LLC03/15/2023
1 project · most recent 03/12/2024
Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/12/2024Signed-offROGERS DEVELOPERS GRP LLCHeating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MSZ-GL06NA-U1 6,000 BTU · Fan Coil Indoor ×16
MSZ-GL12NA-U1 12,000 BTU · Fan Coil Indoor ×8
MXZ-3C24NAHZ2 22,000 BTU · Condensing Unit ×8
PKA-A12HA7 18,000 BTU · Fan Coil Indoor ×2
PUZ-A12NKA7 12,000 BTU · Condensing Unit ×2
MXZ-4C36NAHZ2 36,000 BTU · Condensing Unit ×1
Heating
Qmark ECP1524 300 CFM ×8
CBD750 220 kW · Radiant ×2
CBD500 147 kW · Radiant ×1
Ventilation
Greenheck SP-B110 100 CFM · Exhaust Fan ×10
SP-B90 50 CFM · Exhaust Fan ×10
Enervex BEF 225x 600 CFM ×1
Renewaire EV-90 90 CFM · Erv ×1
1 project · most recent 03/12/2024
Sprinkler System
FiledStatusContractorScope
03/12/2024Signed-offPRIME PIPING & HEATING INSprinkler System
1 project · most recent 03/12/2024
Storm Water/Sanitary
FiledStatusContractorScope
03/12/2024Signed-offA M B MECHANICAL INCStorm, Water/Sanitary
3 projects · most recent 02/08/2024
General Wiring
FiledStatusContractorScope
02/08/2024CompleteHIVOLTS ELECTRICAL INCGeneral Wiring
05/25/2023CompleteSOLAS ELECTRICAL CORP—
04/03/2023CompleteHIVOLTS ELECTRICAL INC—
1 project · most recent 03/12/2024
Steel Concrete
FiledStatusContractorScope
03/12/2024Signed-offROGERS DEVELOPERS GRP LLCSteel, Concrete
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
01/22/2024Pass-Final CND-Occupancy InspectionPassView ↗
12/27/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
12/26/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
12/20/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/19/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
09/11/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
07/21/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/21/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 68
DateRequirementInspectorRole
03/18/2024Structural Steel - DetailsPaul Raymondspecial
03/18/2024FinalPaul Raymondprogress
03/18/2024Structural Steel - WeldingPaul Raymondspecial
03/18/2024Concrete - Cast-In-PlacePaul Raymondspecial
03/18/2024Structural Cold-Formed SteelPaul Raymondspecial
03/18/2024Structural Steel - High Strength BoltingPaul Raymondspecial
03/18/2024Structural Stability – Alterations of existing buildingsPaul Raymondspecial
03/18/2024Post-installed AnchorsPaul Raymondspecial
03/11/2024Structural Steel - High Strength BoltingPaul Raymondspecial
03/11/2024Structural Steel - DetailsPaul Raymondspecial
03/11/2024Structural Stability – Alterations of existing buildingsPaul Raymondspecial
03/11/2024Structural Cold-Formed SteelPaul Raymondspecial
03/11/2024Post-installed AnchorsPaul Raymondspecial
03/11/2024Concrete - Cast-In-PlacePaul Raymondspecial
03/11/2024FinalPaul Raymondprogress
03/11/2024Structural Steel - WeldingPaul Raymondspecial
01/26/2024Fire-Resistant Penetrations and JointsPaul Raymondspecial
01/26/2024Sprinkler SystemsPaul Raymondspecial
01/26/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationPaul Raymondspecial
01/26/2024Energy Code Compliance InspectionsPaul Raymondprogress
01/18/2024Energy Code Compliance InspectionsPaul Raymondprogress
01/18/2024Sprinkler SystemsPaul Raymondspecial
01/18/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationPaul Raymondspecial
01/18/2024Fire-Resistant Penetrations and JointsPaul Raymondspecial
01/11/2024Insulation placement and R valuesPaul Raymondenergy_progress
Latest 25 of 68.
▾Documents — 124 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/28/2026B00798224-I1Request digital key ↗
08/28/2026B00769263-P1Request digital key ↗
08/28/2026B00769263-P2Request digital key ↗
Showing 3 of 12 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026B00769263-I1Open ↗
08/13/2026B00769263-P2Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026B00769263-I1Open ↗
08/13/2026B00769263-P2Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00769263-I1Open ↗
▸Seals & Professional Certifications80
▸DOB NOWSpecial Inspector Seal & Signature34
08/22/2026B00769263-P1Open ↗
08/22/2026B00769263-P1Open ↗
08/22/2026B00769263-P2Open ↗
Showing 3 of 34 on file for this type
▸DOB NOWProgress Inspector Seal & Signature34
08/22/2026B00769263-P2Open ↗
08/22/2026B00769263-P1Open ↗
08/22/2026B00769263-P2Open ↗
Showing 3 of 34 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/27/2026B00879732-I1Open ↗
08/13/2026B00880542-I1Open ↗
08/13/2026B00798224-I1Open ↗
Showing 3 of 12 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026B00769263-I1Open ↗
08/13/2026B00769263-P2Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist2
08/13/2026B00769263-I1Open ↗
08/13/2026B00769263-P2Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00769263-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00769263-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00769263-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/13/2026B00769263-S2Open ↗
08/13/2026B00769263-I1Open ↗
08/13/2026B00769263-S1Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00769263-I1Open ↗
▸Other Documents10
▸DOB NOWPlot Diagram3
08/13/2026B00769263-I1Open ↗
08/13/2026B00769263-P2Open ↗
08/13/2026B00769263-S4Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B00769263-I1Open ↗
08/13/2026B00769263-P2Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026B00769263-P2Open ↗
08/13/2026B00769263-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/13/2026B00769263-I1Open ↗
08/13/2026B00769263-P2Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00769263-I1Open ↗