← Back
Two family brick
1195 RALPH AVENUE
BROOKLYN · BIN 3221658
💬 Discuss this project
1950Year Built
2Stories
B1Building Class
R4Zoning
2,070 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family brick · 2,448 sf lot · 0.85 FAR built · Flood zone X
Locations of Work
Architecture
Basement1p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/14/2020$775K—Private party → Private party$374/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BERINO ARCHITECTURAL DESIGN PLLC209/27/2024
JBA101/18/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DISTINCT ENTERPRISES403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LEVEL UP REMODELING INCGeneral Contractor303/21/2026
WILLIAM JAMES BUSHELL CORGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JIAN ENGINEERING PLLC7397209/27/2024
WORLD DESIGN ARCHITECTURE9323101/18/2024
Building Lifecycle
All (28)Filed (3)Permit Issued (2)Signed Off (1)Violation (6)Objection (8)Special Inspection (8)
10/04/2024
Signed off — Alteration
Minor General Constr. & Structural work to remove infilled masonry wall and window at Basement's garage door opening to restore use of enclosed one car garage as per DOB-ECB summons# 039109497R. No change in exist. use, occupancy, egress, or floor area.
B01037804-I1
10/04/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
JIAN DENG
10/04/2024
Special inspection requirement — Fire-Resistance Rated Construction
JIAN DENG
10/04/2024
Special inspection requirement — Final
JIAN DENG
09/27/2024
Filed — Alteration
Minor General Constr. & Structural work to remove infilled masonry wall and window at Basement's garage door opening to restore use of enclosed one car garage as per DOB-ECB summons# 039109497R. No change in exist. use, occupancy, egress, or floor area.
B01037804-P1
08/28/2024
Permit issued — General Construction
B01037804-I1-GC-CX
05/29/2024
Objection raised — Inspections
05/29/2024
Objection resolved — Addressed
05/29/2024
Objection raised — Fire_Protection
05/29/2024
Objection resolved — Addressed
05/29/2024
Objection raised — Fire_Protection
05/29/2024
Objection resolved — Addressed
05/29/2024
Objection raised — Inspections
05/29/2024
Objection resolved — Addressed
05/21/2024
Filed — Alteration
Minor General Constr. & Structural work to remove infilled masonry wall and window at Basement's garage door opening to restore use of enclosed one car garage as per DOB-ECB summons# 039109497R. No change in exist. use, occupancy, egress, or floor area.
B01037804-I1
05/16/2024
Violation issued (ECB, closed)
Construction
03/21/2024
Violation issued (ECB, closed)
Construction
01/23/2024
Permit issued — Solar
B00988769-I1-SL
01/18/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY OR EGRESS. NO CHANGE IN BULK
B00988769-I1
01/10/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Alicea
01/10/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
William Alicea
01/10/2024
Special inspection requirement — Energy Code Compliance Inspections
JEFFREY BELL
01/10/2024
Special inspection requirement — Final
JEFFREY BELL
01/10/2024
Special inspection requirement — Air barrier - visual inspection
JEFFREY BELL
09/11/2023
Violation issued (ECB, closed)
Construction
12/14/2022
Violation issued (ECB, closed)
Construction
12/14/2022
Violation issued (ECB, closed)
Construction
05/28/2004
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offLEVEL UP REMODELING INC08/28/2024
DOB NOWSolarSigned-offWILLIAM JAMES BUSHELL COR01/23/2024
1 project · most recent 01/17/2024
FiledStatusContractorScope
01/17/2024Permit IssuedD.R.P. ELEC'L CONTRG INC2 meters
1 project · most recent 01/18/2024
FiledStatusContractorScope
01/18/2024Signed-offWILLIAM JAMES BUSHELL COR8 panels, 4.4 kw, 617.5 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
10/04/2024Structural Stability – Alterations of existing buildingsJIAN DENGspecial
10/04/2024Fire-Resistance Rated ConstructionJIAN DENGprogress
10/04/2024FinalJIAN DENGprogress
01/10/2024Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
01/10/2024Structural Stability – Alterations of existing buildingsWilliam Aliceaspecial
01/10/2024Energy Code Compliance InspectionsJEFFREY BELLprogress
01/10/2024FinalJEFFREY BELLprogress
01/10/2024Air barrier - visual inspectionJEFFREY BELLenergy_progress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/26/2026B00988769-I1Request digital key ↗
08/24/2026B01037804-I1Request digital key ↗
08/24/2026B01037804-P1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature5
08/28/2026B00988769-I1Open ↗
08/28/2026B00988769-I1Open ↗
08/28/2026B00988769-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026B01037804-I1Open ↗
08/13/2026B01037804-P1Open ↗
08/13/2026B00988769-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026B00988769-I1Open ↗
08/23/2026B01037804-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/24/2026B01037804-I1Open ↗
08/13/2026B00988769-I1Open ↗
08/13/2026B01037804-P1Open ↗