← Back
Two stories - detached, small or mid-size
12 HASTINGS STREET
💬 Discuss this project
1930Year Built
1.5Stories
A1Building Class
R3-1Zoning
3,451 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 6,000 sf lot · 0.58 FAR built · Flood zone AE
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof8p · 1 filing · 6 docs
Attic7p · 1 filing · 6 docs
Floor 218p · 3 filings · 20 docs
Floor 16p · 2 filings · 20 docs
Cellar19p · 2 filings · 20 docs
Site & exterior2p · 2 filings · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EDWARD BUILDERS103/22/2026
EDWARD BUILDERS INC 1103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/21/2021$2.0M—Private party → Private party$580/sf building
09/14/2016$1.7M—— → —$496/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ERIC SAFYAN ARCHITECT PC1011/06/2023
LEONID KRUPNIK, P.E.110/07/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JOSEPH FELLNER803/21/2026
NYC BUILDINGS HOUSES SOLUTIONS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EDWARD BUILDERS INCGeneral Contractor2107/08/2026
PIPESTYLISTS, INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KALLASSY ENGINEERING PLLC5711611/06/2023
Building Lifecycle
All (74)Filed (11)Permit Issued (14)Signed Off (5)Violation (2)Inspection (6)Objection (6)Special Inspection (30)
04/05/2024
Signed off — Alteration
RENOVATION OF ONE FAMILY DWELLING. PARTITION AND MECHANICAL WORK. SECOND FLOOR HORIZONTAL ENLARGEMENT.
B00653464-I1
04/02/2024
Signed off — Alteration
RENOVATION OF ONE FAMILY DWELLING. PARTITION AND MECHANICAL WORK. SECOND FLOOR HORIZONTAL ENLARGEMENT.
B00653464-S1
03/15/2024
Signed off — Alteration
STRUCTURAL FRAMING PLAN PROPOSED FOR 2ND FLOOR, ATTIC LEVEL AND ROOF. RELATED TO ONGOING CONSTRUCTION WORK AND EXTENSION. FILED IN CONJUNCTION WITH APPLICATION #B006534634
B00795100-I1
11/24/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
11/17/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Joseph El-kallassy
11/17/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Joseph El-kallassy
11/17/2023
Special inspection requirement — Mechanical Systems
Joseph El-kallassy
11/17/2023
Special inspection requirement — Lowest Floor Elevation
Eric Safyan
11/17/2023
Special inspection requirement — Final
Eric Safyan
11/17/2023
Special inspection requirement — Energy Code Compliance Inspections
Joseph El-kallassy
11/17/2023
Special inspection requirement — Fenestration air leakage
Joseph El-kallassy
11/17/2023
Special inspection requirement — Maintenance information
Joseph El-kallassy
11/17/2023
Special inspection requirement — HVAC-R and service water heating system controls
Joseph El-kallassy
11/17/2023
Special inspection requirement — HVAC-R and service water heating equipment
Joseph El-kallassy
11/17/2023
Special inspection requirement — Lighting in dwelling units
Joseph El-kallassy
11/17/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Joseph El-kallassy
11/17/2023
Special inspection requirement — Permanent certificate
Joseph El-kallassy
11/17/2023
Special inspection requirement — Fenestration areas
Joseph El-kallassy
11/17/2023
Special inspection requirement — Air barrier - visual inspection
Joseph El-kallassy
11/17/2023
Special inspection requirement — Fire-Resistance Rated Construction
Joseph El-kallassy
11/17/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Joseph El-kallassy
11/17/2023
Special inspection requirement — Insulation placement and R values
Joseph El-kallassy
11/14/2023
Objection resolved — Addressed
11/13/2023
Objection raised — Scope
11/06/2023
Filed — Alteration
RENOVATION OF ONE FAMILY DWELLING. PARTITION AND MECHANICAL WORK. SECOND FLOOR HORIZONTAL ENLARGEMENT.
B00653464-A1
11/02/2023
Filed — Alteration
RENOVATION OF ONE FAMILY DWELLING. PARTITION AND MECHANICAL WORK. SECOND FLOOR HORIZONTAL ENLARGEMENT.
B00653464-P9
11/02/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Joseph El-kallassy
11/02/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Eric Safyan
11/02/2023
Special inspection requirement — Mechanical Systems
Joseph El-kallassy
11/02/2023
Special inspection requirement — HVAC-R and service water heating system controls
Eric Safyan
11/02/2023
Special inspection requirement — HVAC-R and service water heating system controls
Eric Safyan
11/02/2023
Special inspection requirement — HVAC-R and service water heating equipment
Eric Safyan
11/02/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Joseph El-kallassy
11/02/2023
Special inspection requirement — Energy Code Compliance Inspections
Eric Safyan
11/02/2023
Special inspection requirement — HVAC-R and service water heating equipment
Eric Safyan
11/02/2023
Special inspection requirement — Energy Code Compliance Inspections
Eric Safyan
11/02/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Eric Safyan
11/02/2023
Special inspection requirement — Energy Code Compliance Inspections
Joseph El-kallassy
10/30/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/21/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/30/2023
Permit issued — Plumbing
B00653464-S1-PL
07/17/2023
Permit issued — Mechanical Systems
B00653464-I1-GC-CX
06/06/2023
Signed off — Alteration
REMOVAL OF INTERIOR NON LOAD BEARING PARTITIONS, EXTERIOR DECK. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
B00637749-I1
05/24/2023
Permit issued — General Construction
B00637749-I1-GC
05/24/2023
Permit issued — General Construction
B00637749-I1-GC
05/24/2023
Permit issued — General Construction
B00637749-I1-GC
04/17/2023
Signed off — Alteration
B00636133-I1
04/03/2023
Permit issued — Mechanical Systems
B00653464-I1-GC-CX
03/17/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/17/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/22/2023
Permit issued — Structural
B00795100-I1-ST
02/01/2023
Objection resolved — Addressed
01/31/2023
Objection raised — Other
01/30/2023
Filed — Alteration
RENOVATION OF ONE FAMILY DWELLING. PARTITION AND MECHANICAL WORK. SECOND FLOOR HORIZONTAL ENLARGEMENT.
B00653464-P8
01/30/2023
Filed — Alteration
RENOVATION OF ONE FAMILY DWELLING. PARTITION AND MECHANICAL WORK. SECOND FLOOR HORIZONTAL ENLARGEMENT.
B00653464-P6
01/25/2023
Permit issued — Mechanical Systems
B00653464-I1-GC-CX
12/09/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/05/2022
Permit issued — Construction Fence
B00636133-I1-FN
10/12/2022
Objection raised — Other
10/12/2022
Objection resolved — Addressed
Latest 60 of 74 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offT & T PLUMBING INC08/30/2023
DOB NOWMechanical SystemsSigned-offDELRIC CONSTRUCTION CO07/17/2023
DOB NOWGeneral ConstructionSigned-offDELRIC CONSTRUCTION CO05/24/2023
DOB NOWGeneral ConstructionSigned-offDELRIC CONSTRUCTION CO05/24/2023
DOB NOWGeneral ConstructionSigned-offDELRIC CONSTRUCTION CO05/24/2023
DOB NOWMechanical SystemsSigned-offDELRIC CONSTRUCTION CO04/03/2023
DOB NOWStructuralSigned-offDELRIC CONSTRUCTION CO02/22/2023
DOB NOWMechanical SystemsSigned-offDELRIC CONSTRUCTION CO01/25/2023
DOB NOWConstruction FenceSigned-offDELRIC CONSTRUCTION CO12/05/2022
DOB NOWMechanical SystemsSigned-offDELRIC CONSTRUCTION CO08/31/2022
DOB NOWPlumbingSigned-offT & T PLUMBING INC04/28/2022
DOB NOWMechanical SystemsSigned-offDELRIC CONSTRUCTION CO03/09/2022
DOB NOWGeneral ConstructionSigned-offDELRIC CONSTRUCTION CO12/09/2021
DOB NOWConstruction FenceSigned-offDELRIC CONSTRUCTION CO11/24/2021
BISMHISSUEDEDWARD BUILDERS INC10/04/2018
1 project · most recent 05/08/2023
General Wiring
FiledStatusContractorScope
05/08/2023CompleteARC POWER ELECL CONTS INCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
11/24/2023Pass-Final General Construction Non-Directive 14PassView ↗
10/30/2023Fail-Final General Construction Non-Directive 14FailView ↗
09/21/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/17/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/17/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/09/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 105
DateRequirementInspectorRole
11/17/2023Lighting in dwelling unitsJoseph El-kallassyenergy_progress
11/17/2023Maintenance informationJoseph El-kallassyenergy_progress
11/17/2023HVAC-R and service water heating system controlsJoseph El-kallassyenergy_progress
11/17/2023Mechanical SystemsJoseph El-kallassyspecial
11/17/2023Fire-Resistant Penetrations and JointsJoseph El-kallassyspecial
11/17/2023Structural Stability – Alterations of existing buildingsJoseph El-kallassyspecial
11/17/2023Energy Code Compliance InspectionsJoseph El-kallassyprogress
11/17/2023Fire-Resistance Rated ConstructionJoseph El-kallassyprogress
11/17/2023Lowest Floor ElevationEric Safyanprogress
11/17/2023FinalEric Safyanprogress
11/17/2023Air barrier - visual inspectionJoseph El-kallassyenergy_progress
11/17/2023Insulation placement and R valuesJoseph El-kallassyenergy_progress
11/17/2023HVAC-R and service water piping design and insulationJoseph El-kallassyenergy_progress
11/17/2023Fenestration air leakageJoseph El-kallassyenergy_progress
11/17/2023Fenestration and door U-factor and product ratingsJoseph El-kallassyenergy_progress
11/17/2023Fenestration areasJoseph El-kallassyenergy_progress
11/17/2023Permanent certificateJoseph El-kallassyenergy_progress
11/17/2023HVAC-R and service water heating equipmentJoseph El-kallassyenergy_progress
11/02/2023Energy Code Compliance InspectionsJoseph El-kallassyprogress
11/02/2023Structural Stability – Alterations of existing buildingsJoseph El-kallassyspecial
11/02/2023Mechanical SystemsJoseph El-kallassyspecial
11/02/2023Fire-Resistant Penetrations and JointsJoseph El-kallassyspecial
11/02/2023HVAC-R and service water piping design and insulationEric Safyanenergy_progress
11/02/2023HVAC-R and service water heating equipmentEric Safyanenergy_progress
11/02/2023HVAC-R and service water heating system controlsEric Safyanenergy_progress
Latest 25 of 105.
▾Documents — 181 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/31/2026B00636133-I1Request digital key ↗
08/31/2026B00637749-I1Request digital key ↗
08/26/2026B00653464-P6Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION4
09/21/2021321744458Open ↗
09/20/2021321744458Open ↗
09/20/2021321744458Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION2
10/05/2018321744458Open ↗
10/05/2018321744458Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
01/15/2019321744458Open ↗
▸Zoning, Tax Lot & Property Records14
▸DOB NOWZD1: DOB Zoning Diagram5
08/13/2026B00653464-P8Open ↗
08/13/2026B00653464-P2Open ↗
08/13/2026B00653464-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWZoning Exhibit form (1-5)5
08/13/2026B00653464-P8Open ↗
08/13/2026B00653464-P1Open ↗
08/13/2026B00653464-I1Open ↗
Showing 3 of 5 on file for this type
▸BISZONING DIAGRAM2
05/28/2019321744458Open ↗
06/12/2018321744458Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
06/07/2018321744458Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
06/07/2018321744458Open ↗
▸Seals & Professional Certifications112
▸DOB NOWProgress Inspector Seal & Signature81
09/27/2026B00653464-S1Open ↗
09/27/2026B00653464-S1Open ↗
09/20/2026B00637749-I1Open ↗
Showing 3 of 81 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature16
09/01/2026B00795100-I1Open ↗
09/01/2026B00653464-P2Open ↗
09/01/2026B00653464-P2Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/26/2026B00653464-A1Open ↗
08/26/2026B00653464-P9Open ↗
08/26/2026B00653464-P8Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
10/05/2018321744458Open ↗
10/05/2018321744458Open ↗
06/21/2018321744458Open ↗
Showing 3 of 4 on file for this type
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
04/26/2018321744458Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
04/26/2018321744458Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
10/05/2018321744458Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/26/2026B00653464-P6Open ↗
08/26/2026B00653464-P9Open ↗
08/26/2026B00653464-P2Open ↗
Showing 3 of 10 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/26/2018321744458Open ↗
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026B00653464-S1Open ↗
08/13/2026B00653464-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
04/26/2018321744458Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
04/26/2018321744458Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
04/26/2018321744458Open ↗
▸BISADDITIONAL INFORMATION1
02/01/2019321744458Open ↗
▸Other Documents17
▸DOB NOWPlot Diagram5
08/13/2026B00653464-P8Open ↗
08/13/2026B00653464-P2Open ↗
08/13/2026B00653464-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/13/2026B00653464-I1Open ↗
08/13/2026B00653464-P1Open ↗
08/13/2026B00653464-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSite Survey: Initial5
08/13/2026B00653464-P2Open ↗
08/13/2026B00653464-A1Open ↗
08/13/2026B00653464-I1Open ↗
Showing 3 of 5 on file for this type
▸BISLOCAL LAW - SUPPPORTING DOCUMENTATION1
09/20/2021321744458Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
06/21/2018321744458Open ↗