← Back
Two family converted from one family
120-19 131 STREET
QUEENS · BIN 4254992
💬 Discuss this project
1920Year Built
2Stories
B3Building Class
R3-2Zoning
1,452 sfGross Floor Area
2Units
11 Open Violations 8 unresolved · 3 paperwork only ▸FDNY Report ↗
Two family converted from one family · Owner of record: AHUJA NY LLC · 4,470 sf lot · 0.32 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbing
Roof2p · 1 filing · 18 docs
Floor 21p · 1 filing · 18 docs
Floor 1
Cellar6p · 1 filing · 18 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AHUJA603/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/09/2024$570K—— → —$393/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NASIR J, KHANZADA LLC302/18/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NASIR J. KHANZADA LLC603/21/2026
Building Lifecycle
All (65)Filed (3)Violation (11)Objection (23)Special Inspection (28)
09/21/2026
Objection raised — Other
08/13/2026
Objection resolved — Resolved
08/12/2026
Objection raised — Zoning
07/22/2026
Objection resolved — Addressed
07/22/2026
Objection resolved — Addressed
07/22/2026
Objection resolved — Addressed
07/17/2026
Objection resolved — Addressed
07/09/2026
Objection raised — Other
07/09/2026
Objection raised — Other
07/09/2026
Objection raised — Other
07/09/2026
Objection raised — Other
06/08/2026
Objection resolved — Addressed
04/03/2026
Special inspection requirement — Metering
04/03/2026
Special inspection requirement — Electric vehicle service equipment requirements
03/23/2026
Objection resolved — Addressed
03/23/2026
Objection resolved — Resolved
03/23/2026
Objection resolved — Resolved
03/23/2026
Objection resolved — Resolved
03/23/2026
Objection resolved — Addressed
03/23/2026
Special inspection requirement — Maintenance information
03/18/2026
Objection raised — Admin
03/18/2026
Objection raised — Inspections
03/18/2026
Objection raised — Scope
03/18/2026
Objection raised — Scope
03/18/2026
Objection raised — Mechanical
03/18/2026
Objection raised — Plumbing
02/18/2026
Filed — Alteration CO
ALT-1 FILING TO CONVERSION ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH ADDING AN ADU (ANCILLARY DWELLING UNIT) AT REAR.
Q01355648-S1
02/18/2026
Filed — Alteration CO
ALT-1 FILING TO CONVERSION ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH ADDING AN ADU (ANCILLARY DWELLING UNIT) AT REAR.
Q01355648-S2
02/18/2026
Filed — Alteration CO
ALT-1 FILING TO CONVERSION ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH ADDING AN ADU (ANCILLARY DWELLING UNIT) AT REAR.
Q01355648-I1
02/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/17/2026
Special inspection requirement — HVAC-R and service water heating system controls
02/17/2026
Special inspection requirement — HVAC-R and service water heating equipment
02/17/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
02/12/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
02/12/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
02/12/2026
Special inspection requirement — Concrete - Cast-In-Place
02/12/2026
Special inspection requirement — Subgrade Inspections
02/12/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
02/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/12/2026
Special inspection requirement — Permanent certificate
02/12/2026
Special inspection requirement — Protection of exposed foundation insulation
02/12/2026
Special inspection requirement — Fenestration areas
02/12/2026
Special inspection requirement — Fenestration air leakage
02/12/2026
Special inspection requirement — Energy Code Compliance Inspections
02/12/2026
Special inspection requirement — Fire-Resistance Rated Construction
02/12/2026
Special inspection requirement — Structural Wood Frame
02/12/2026
Special inspection requirement — Insulation placement and R values
02/12/2026
Special inspection requirement — Interior lighting power
02/12/2026
Special inspection requirement — Air barrier - visual inspection
02/12/2026
Special inspection requirement — Maintenance information
02/10/2026
Special inspection requirement — Masonry
02/05/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
02/04/2026
Special inspection requirement — Footing and Foundation
02/04/2026
Special inspection requirement — Final
12/05/2024
Violation issued (ECB, open)
Construction
09/25/2002
Violation issued (HPD, open)
C
09/25/2002
Violation issued (HPD, open)
C
09/25/2002
Violation issued (HPD, open)
C
05/24/1998
Violation issued (ECB, open)
Quality of Life
09/08/1997
Violation issued (DOB, open)
VP-VIOLATION UNSERVED ECB-ACTIVE
Latest 60 of 65 events.
Nothing on file for this building.
1 project · most recent 02/18/2026
Concrete Masonry Wood
FiledStatusContractorScope
02/18/2026——Concrete, Masonry, Wood
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
04/03/2026Metering—energy_progress
04/03/2026Electric vehicle service equipment requirements—energy_progress
03/23/2026Maintenance information—energy_progress
02/17/2026Fire-Resistant Penetrations and Joints—special
02/17/2026HVAC-R and service water heating system controls—energy_progress
02/17/2026HVAC-R and service water heating equipment—energy_progress
02/17/2026HVAC-R and service water piping design and insulation—energy_progress
02/12/2026Fenestration and door U-factor and product ratings—energy_progress
02/12/2026Subsurface Investigations (Borings/Test Pits)—special
02/12/2026Concrete - Cast-In-Place—special
02/12/2026Subgrade Inspections—special
02/12/2026Excavations - Sheeting, Shoring, and Bracing—special
02/12/2026Fire-Resistant Penetrations and Joints—special
02/12/2026Permanent certificate—energy_progress
02/12/2026Protection of exposed foundation insulation—energy_progress
02/12/2026Fenestration areas—energy_progress
02/12/2026Fenestration air leakage—energy_progress
02/12/2026Energy Code Compliance Inspections—progress
02/12/2026Fire-Resistance Rated Construction—progress
02/12/2026Structural Wood Frame—progress
02/12/2026Insulation placement and R values—energy_progress
02/12/2026Interior lighting power—energy_progress
02/12/2026Air barrier - visual inspection—energy_progress
02/12/2026Maintenance information—energy_progress
02/10/2026Masonry—special
Latest 25 of 28.
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026Q01355648-S1Request digital key ↗
08/17/2026Q01355648-I1Request digital key ↗
08/17/2026Q01355648-S2Request digital key ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/17/2026Q01355648-I1Open ↗
08/13/2026Q01355648-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/17/2026Q01355648-I1Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/17/2026Q01355648-I1Open ↗
08/17/2026Q01355648-S2Open ↗
08/13/2026Q01355648-I1Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/17/2026Q01355648-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01355648-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/17/2026Q01355648-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification1
08/13/2026Q01355648-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01355648-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/17/2026Q01355648-I1Open ↗
▸DOB NOWPlot Diagram1
08/17/2026Q01355648-I1Open ↗