← Back
Unlicensed parking lot
120-30 JAMAICA AVENUE
QUEENS · Richmond Hill · BIN 4625146
💬 Discuss this project
0Year Built
—Stories
G7Building Class
M1-5Zoning
0 sfGross Floor Area
0Units
3 Open Violations 1 unresolved · 2 paperwork only ▸FDNY Report ↗
Unlicensed parking lot · Owner of record: NYC SCHOOL CONSTRUCTION AUTHORITY · 5,300 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneralOther
Permit Issued — active, not yet Signed-off
RoofUnder Construction40p · 3 filings · 20 docs
Floor 4Under Construction42p · 2 filings · 20 docs
Floor 3Under Construction44p · 2 filings · 20 docs
Floor 2Under Construction43p · 2 filings · 20 docs
Floor 1Under Construction43p · 2 filings · 20 docs
Sub-BasementUnder Construction38p · 2 filings · 20 docs
Site & exteriorUnder Construction20p · 3 filings · 20 docs
Filed — no permit issued175p · 8 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC SCHOOL CONSTRUCTION4708/14/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JMV ASSOCIATES603/21/2026
JM ZONING, LLC.4203/21/2026
A1 EXPEDITING SERVICE CORP.103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MPCC CORPGeneral Contractor1008/14/2026
PJP INSTALLERS INCGeneral Contractor206/28/2026
I.M.P. PLBG & HTG CORPFire Protection108/14/2026
I.M.P. PLBG. & HTG. CORPPlumbing108/14/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
UNIVERSAL TESTING AND INS400901/30/2026
Building Lifecycle
All (148)Filed (37)Permit Issued (15)Violation (3)Inspection (1)Objection (62)Special Inspection (30)
09/23/2026
Permit issued — Sidewalk Shed
Q01340631-I1-SH
09/03/2026
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
08/13/2026
Permit issued — Sprinklers
Q01043777-S6-EW-SP
08/13/2026
Permit issued — Plumbing
Q01043777-S2-PL
08/13/2026
Permit issued — Structural
Q01043777-S3-ST
08/13/2026
Permit issued — Earth Work
Q01043777-S4-GC-CX
08/13/2026
Permit issued — General Construction
Q01043777-I1-GC
08/07/2026
Permit issued — Mechanical Systems
Q01043777-S1-MS
07/30/2026
Filed — Alteration
Herewith filing Plumbing work for early removals
Q01043777-P3
07/21/2026
Permit issued — Protection and Mechanical Methods
Q01294068-I1-PMM
07/17/2026
Permit issued — Protection and Mechanical Methods
Q01294068-I1-PMM
07/15/2026
Permit issued — Construction Fence
Q01267297-I1-FN
07/15/2026
Permit issued — Protection and Mechanical Methods
Q01294068-I1-PMM
06/22/2026
Permit issued — Sidewalk Shed
Q01340631-I1-SH
04/15/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
NELSON LOPEZ
04/15/2026
Special inspection requirement — Final
NELSON LOPEZ
04/08/2026
Objection resolved — Addressed
04/03/2026
Permit issued — Sidewalk Shed
Q01340631-I1-SH
04/01/2026
Filed — Alteration
Herewith filing Plumbing work for early removals
Q01043777-P2
03/13/2026
Special inspection requirement — Luminous Exit Path Markings
03/13/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/13/2026
Special inspection requirement — Air barrier continuity plan testing
03/13/2026
Special inspection requirement — Lighting controls
03/13/2026
Special inspection requirement — Energy Code Compliance Inspections
03/13/2026
Special inspection requirement — Exterior lighting power
03/13/2026
Special inspection requirement — Preliminary
03/13/2026
Special inspection requirement — Air barrier - visual inspection
03/13/2026
Special inspection requirement — Fire-Resistance Rated Construction
03/13/2026
Special inspection requirement — Protection of exposed foundation insulation
03/13/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
03/13/2026
Special inspection requirement — Vestibules
03/13/2026
Special inspection requirement — Masonry
03/13/2026
Special inspection requirement — Electrical motors and elevators
03/13/2026
Special inspection requirement — Insulation placement and R values
03/13/2026
Special inspection requirement — Fenestration air leakage
03/13/2026
Special inspection requirement — Metering
03/13/2026
Special inspection requirement — Air barrier — testing
03/13/2026
Special inspection requirement — Fenestration areas
03/13/2026
Special inspection requirement — Interior lighting power
03/12/2026
Objection raised — Other
03/12/2026
Objection resolved — Addressed
03/12/2026
Objection resolved — Addressed
03/11/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Herewith filing subsequent Mechanical and OT lighting application for Alt-CO
Q01110799-P1
03/05/2026
Special inspection requirement — Masonry
03/05/2026
Special inspection requirement — Preliminary
03/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/05/2026
Special inspection requirement — Energy Code Compliance Inspections
03/05/2026
Special inspection requirement — Air barrier — testing
03/05/2026
Special inspection requirement — Luminous Exit Path Markings
03/05/2026
Special inspection requirement — Fire-Resistance Rated Construction
03/05/2026
Special inspection requirement — Insulation placement and R values
03/04/2026
Objection resolved — Addressed
03/03/2026
Objection resolved — Addressed
02/26/2026
Objection resolved — Addressed
02/26/2026
Objection resolved — Addressed
02/26/2026
Objection resolved — Addressed
02/17/2026
Objection resolved — Addressed
02/12/2026
Objection resolved — Addressed
02/06/2026
Permit issued — Construction Fence
Q01267297-I1-FN
02/06/2026
Objection raised — Other
Latest 60 of 148 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedTT & T CONSTRUCTION INC09/23/2026
DOB NOWSprinklersPermit IssuedI.M.P. PLBG & HTG CORP08/13/2026
DOB NOWPlumbingPermit IssuedI.M.P. PLBG. & HTG. CORP08/13/2026
DOB NOWStructuralPermit IssuedMPCC CORP08/13/2026
DOB NOWEarth WorkPermit IssuedMPCC CORP08/13/2026
DOB NOWGeneral ConstructionPermit IssuedMPCC CORP08/13/2026
DOB NOWMechanical SystemsPermit IssuedMPCC CORP08/07/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedMPCC CORP07/21/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedMPCC CORP07/17/2026
DOB NOWConstruction FencePermit IssuedMPCC CORP07/15/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedMPCC CORP07/15/2026
DOB NOWSidewalk ShedPermit IssuedPJP INSTALLERS INC06/22/2026
DOB NOWSidewalk ShedPermit IssuedPJP INSTALLERS INC04/03/2026
DOB NOWConstruction FencePermit IssuedMPCC CORP02/06/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedMPCC CORP02/05/2026
3 projects · most recent 03/11/2026
Others Heating and Air Conditioning Systems Ventilation Systems Generators
FiledStatusContractorScopeMake / Model / Capacity
03/11/2026——Heating and Air Conditioning Systems, Others, Ventilation Systems
Heat / Cool
Lg ARUM241DTE5 20 tons · Vrf Outdoor ×36
ARUM144DTE5 12 tons · Vrf Outdoor ×12
ARNU243SKS4 24,200 BTU · Vrf Indoor ×10
ARUM168DTE5 14 tons · Vrf Outdoor ×8
ARUN024GSS4 27,000 BTU · Vrf Outdoor ×8
ARNU123SJS4 12,300 BTU · Vrf Indoor ×6
ARUN060GSS4 64,000 BTU · Vrf Outdoor ×4
ARNU243TAA4 24,200 BTU · Vrf Indoor ×2
ARNU303SVA4 30,000 BTU · Vrf Indoor ×2
Annexair AHU-I-07-HE-D-HR-SS 6,800 CFM · Split System ×8
ERP-I-07-EW02-HE-D-HR-SS 8,000 CFM · Split System ×8
ERP-I-12-EW05-HE-D-HR-SS 13,500 CFM · Split System ×8
ERP-I-16-EW07-HE-D-HR-SS 15,000 CFM · Split System ×8
ERP-I-16-EW09-HE-D-HR-SS 15,500 CFM · Split System ×8
Ventilation
Greenheck G-080-VG 250 CFM · Exhaust Fan ×4
G-090-VG 450 CFM · Exhaust Fan ×4
CUBE-200-VGD-15 4,500 CFM · Exhaust Fan ×2
CUBE-300XP-VGD-30 3,620 CFM · Exhaust Fan ×2
CUE-300-C-VGD 10,000 CFM · Exhaust Fan ×2
G-060-VG 100 CFM · Exhaust Fan ×2
G-100-VG 1,090 CFM · Exhaust Fan ×2
G-100HP-VG 320 CFM · Exhaust Fan ×2
G-130-VG 1,908 CFM · Exhaust Fan ×2
G-200-VG 3,780 CFM · Exhaust Fan ×2
SQ-80-VG 200 CFM · Exhaust Fan ×2
Other
Obar Systems OBAR GBR89 150 CFM ×3
04/09/2025——Others
Other
Obar Systems OBAR GBR89 150 CFM ×3
10/31/2024——Generators
Generators
Mtu 6R0225 DS350 350 kW · Generator ×1
2 projects · most recent 07/30/2026
FiledStatusContractorScope
07/30/2026Permit IssuedI.M.P. Plumbing & Heating CORP.6 heads
10/30/2024——993 heads, 4 outlets
2 projects · most recent 07/30/2026
Storm Water/Sanitary Gas
FiledStatusContractorScope
07/30/2026Permit IssuedI.M.P. PLUMBING & HEATING CORP.Gas, Storm, Water/Sanitary
03/11/2026——Storm, Water/Sanitary
2 projects · most recent 07/15/2026
FiledStatusContractorScope
07/15/2026Permit IssuedARK SYSTEMS ELEC. CORP1 meters, 1 new_meters
02/25/2026Permit IssuedLIT MODE ELECL CONTG INC—
3 projects · most recent 07/30/2026
FiledStatusContractorScope
07/30/2026Permit IssuedMPCC CORP4 scope_items
03/11/2026——1 scope_items
09/23/2024——1 scope_items
2 projects · most recent 01/27/2026
Sidewalk Shed Fence
FiledStatusContractorScope
01/27/2026Permit IssuedPJP INSTALLERS INCSidewalk Shed
10/21/2025Permit IssuedMPCC CORPFence
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
09/03/2026Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 125
DateRequirementInspectorRole
04/15/2026FinalNELSON LOPEZprogress
04/15/2026Structural Stability – Alterations of existing buildingsNELSON LOPEZspecial
03/13/2026Lighting controls—energy_progress
03/13/2026Air barrier - visual inspection—energy_progress
03/13/2026Luminous Exit Path Markings—special
03/13/2026Preliminary—progress
03/13/2026Energy Code Compliance Inspections—progress
03/13/2026Fire-Resistant Penetrations and Joints—special
03/13/2026Fire-Resistance Rated Construction—progress
03/13/2026Masonry—special
03/13/2026Fenestration and door U-factor and product ratings—energy_progress
03/13/2026Protection of exposed foundation insulation—energy_progress
03/13/2026Vestibules—energy_progress
03/13/2026Exterior lighting power—energy_progress
03/13/2026Electrical motors and elevators—energy_progress
03/13/2026Insulation placement and R values—energy_progress
03/13/2026Fenestration air leakage—energy_progress
03/13/2026Metering—energy_progress
03/13/2026Air barrier — testing —energy_progress
03/13/2026Interior lighting power—energy_progress
03/13/2026Fenestration areas—energy_progress
03/13/2026Air barrier continuity plan testing—energy_progress
03/05/2026Preliminary—progress
03/05/2026Energy Code Compliance Inspections—progress
03/05/2026Masonry—special
Latest 25 of 125.
▾Documents — 234 on file (BIS + DOB NOW)
▸Plans & Drawings34
▸DOB NOWPlans/Sketch31
08/22/2026Q01043777-P3Request digital key ↗
08/22/2026Q01043777-P2Request digital key ↗
08/21/2026Q01086525-S1Request digital key ↗
Showing 3 of 31 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly3
08/21/2026Q01121631-I1Request digital key ↗
08/21/2026Q01121620-I1Request digital key ↗
08/21/2026Q01121599-I1Request digital key ↗
▸Applications & Permits2
▸DOB NOWDEP Stormwater Construction Permit2
08/13/2026Q01110799-S8Open ↗
08/13/2026Q01110799-S4Open ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026Q01110799-P1Open ↗
08/13/2026Q01110799-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/13/2026Q01110799-P1Open ↗
08/13/2026Q01110799-I1Open ↗
▸Seals & Professional Certifications52
▸DOB NOWDPL-1: Design Professional Seal & Signature35
08/22/2026Q01043777-S1Open ↗
08/22/2026Q01043777-I1Open ↗
08/22/2026Q01043777-S2Open ↗
Showing 3 of 35 on file for this type
▸DOB NOWProgress Inspector Seal & Signature9
09/02/2026Q01086525-S3Open ↗
08/28/2026Q01043777-P1Open ↗
08/25/2026Q01043777-S3Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/02/2026Q01086525-S3Open ↗
09/02/2026Q01086525-S1Open ↗
08/30/2026Q01043777-S7Open ↗
Showing 3 of 8 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWNYCSCA - Approved Site Safety Plans3
08/13/2026Q01267297-I1Open ↗
Showing 1 of 3 on file for this type
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form7
08/15/2026Q01043777-S2Open ↗
08/15/2026Q01043777-S7Open ↗
08/15/2026Q01043777-S6Open ↗
Showing 3 of 7 on file for this type
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01110799-S4Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q01110799-S4Open ↗
▸Approvals, Objections & Sign-offs86
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)34
08/22/2026Q01043777-P2Open ↗
08/22/2026Q01043777-P3Open ↗
08/15/2026Q01043777-S7Open ↗
Showing 3 of 34 on file for this type
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter34
08/22/2026Q01043777-P2Open ↗
08/22/2026Q01043777-P3Open ↗
08/18/2026Q01267297-P1Open ↗
Showing 3 of 34 on file for this type
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)18
08/15/2026Q01043777-S7Open ↗
08/13/2026Q01086525-S3Open ↗
08/13/2026Q01086525-I1Open ↗
Showing 3 of 18 on file for this type
▸Other Documents44
▸DOB NOWNYCSCA - BCC Plan Examination Transmittal36
08/22/2026Q01043777-P2Open ↗
08/22/2026Q01043777-P3Open ↗
08/15/2026Q01043777-S7Open ↗
Showing 3 of 36 on file for this type
▸DOB NOWSite Survey: Initial5
08/13/2026Q01110799-S9Open ↗
08/13/2026Q01110799-I1Open ↗
08/13/2026Q01110799-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProperty Ownership Certification2
08/20/2026Q01110799-I1Open ↗
08/14/2026Q01110799-P1Open ↗
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/14/2026Q01043777-S3Open ↗