| Owner | Filings | Most Recent |
|---|---|---|
| Little Man Development | 26 | 07/08/2026 |
| Greenpoint Bank | 8 | 03/21/2026 |
| Home Savings of America | 7 | 03/21/2026 |
| Capital One Bank | 4 | 03/21/2026 |
| 120-32 QB | 1 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 07/26/2021 | $3.0M | — | — → — | $292/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| Infocus Design and Planning | 12 | 08/05/2024 |
| Murdoch Engineering | 2 | 05/02/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| XH&RC Plumbing and Heating | 2 | 03/21/2026 |
| All in Permit Consultants | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Morgan Services Group | General Contractor | 4 | 07/08/2026 |
| Gamco Contracting | General Contractor | 2 | 07/08/2026 |
| Bold Enterprises | Scaffold | 1 | 04/09/2026 |
| Gamco Contracting | Scaffold | 1 | 04/09/2026 |
| Neptune Signs & Awnings | Sign hanger | 1 | 07/08/2026 |
| Plumbing P & H | Plumbing | 1 | 07/08/2026 |
| XH&RC Plumbing and Heating | Plumbing | 1 | 07/08/2026 |
| Neptune Signs & Awnings I | specialty_contractor | 1 | 04/09/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Infocus Design & Planning | 932 | 6 | 03/28/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sign | Signed-off | Desthers, Joseph | 06/26/2024 |
| DOB NOW | General Construction | Signed-off | Neptune Signs & Awnings I | 06/06/2024 |
| DOB NOW | Construction Fence | Signed-off | Gamco Contracting | 03/01/2024 |
| DOB NOW | Mechanical Systems | Signed-off | Gamco Contracting | 01/30/2024 |
| DOB NOW | General Construction | Permit Issued | Gamco Contracting | 01/29/2024 |
| DOB NOW | Plumbing | Signed-off | XH&RC Plumbing and Heating | 01/22/2024 |
| DOB NOW | Construction Fence | Signed-off | Bold Enterprises | 06/14/2023 |
| DOB NOW | General Construction | Permit Issued | Morgan Services Group | 10/14/2022 |
| DOB NOW | Plumbing | Signed-off | Plumbing P & H | 09/07/2022 |
| DOB NOW | General Construction | Permit Issued | Morgan Services Group | 11/12/2021 |
| BIS | BL | ISSUED | New York Plumbing-Heating-Cooling | 01/04/2016 |
| BIS | PL | ISSUED | New York Plumbing-Heating-Cooling | 01/04/2016 |
| BIS | MH | ISSUED | Metropolitan Mechanical | 10/14/2011 |
| BIS | MH | ISSUED | Metropolitan Mechanical | 08/11/2011 |
| BIS | — | ISSUED | American Sign & Electrical Con | 08/31/2007 |
| BIS | PL | ISSUED | Beta Plumbing & Heating | 07/19/2005 |
| BIS | MH | ISSUED | Integra Construction of NY | 04/14/2005 |
| BIS | OT | ISSUED | Integra Construction of NY | 04/14/2005 |
| BIS | PL | ISSUED | Schmelz Brothers | 09/19/2003 |
| BIS | MH | ISSUED | Alix Contracting Co | 09/17/2003 |
| BIS | EQ | ISSUED | Advanced Installation | 05/21/2003 |
| BIS | MH | ISSUED | Winco Maintenance T/A Meltzer WI | 06/25/1997 |
| BIS | OT | ISSUED | Winco Maintenance T/A Meltzer WI | 06/24/1997 |
| BIS | — | ISSUED | Going Sign Co | 09/15/1995 |
| BIS | — | ISSUED | Going Sign Co | 09/15/1995 |
| BIS | — | ISSUED | Going Sign Co | 09/15/1995 |
| BIS | — | ISSUED | Going Sign Co | 09/15/1995 |
| BIS | PL | ISSUED | I.M.P. Plumbing & Heating | 03/01/1993 |
| BIS | — | ISSUED | Universal Unlimited | 04/14/1992 |
| BIS | — | ISSUED | Universal Unlimited | 04/14/1992 |
| BIS | — | ISSUED | Universal Unlimited | 04/14/1992 |
| BIS | — | ISSUED | Universal Unlimited | 04/14/1992 |
| BIS | — | ISSUED | Universal Unlimited | 04/14/1992 |
| BIS | — | ISSUED | Universal Unlimited | 04/14/1992 |
| BIS | — | ISSUED | Advanced Asbestos Removal | 08/16/1991 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/05/2024 | Signed-off | Gamco Contracting | Air Conditioning Systems, Refrigeration Systems, Ventilation Systems | Cooling Mitsubishi Electric PUHY-P168TNU-A 168,000 BTU · Vrf Outdoor ×2 Ventilation Captiveaire DU85H 1,715 CFM · Kitchen Exhaust ×2 Refrigeration |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/05/2024 | Signed-off | XH&RC Plumbing and Heating | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/18/2026 | Permit Issued | Blu Electrical Services | General Wiring |
| 06/27/2024 | Complete | Proff Electrical | General Wiring |
| 06/26/2024 | Complete | Proff Electrical | — |
| 06/26/2024 | Complete | Proff Electrical | — |
| 03/28/2024 | Complete | Grey Goose Electric | 3 meters, 1 new_meters |
| 02/26/2024 | Permit Issued | Foster Electrical Service | General Wiring |
| 04/14/2022 | Complete | Star Electrical Contractors | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/24/2023 | Signed-off | Gamco Contracting | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/16/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/09/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 03/07/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 02/08/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 01/31/2023 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 09/16/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 05/13/2024 | Fire-Resistance Rated Construction | WU(WOODY) CHEN | progress |
| 05/13/2024 | Fire-Resistant Penetrations and Joints | WU(WOODY) CHEN | special |
| 05/13/2024 | Energy Code Compliance Inspections | WU(WOODY) CHEN | progress |
| 05/13/2024 | Interior lighting power | WU(WOODY) CHEN | energy_progress |
| 05/13/2024 | Maintenance information | WU(WOODY) CHEN | energy_progress |
| 05/13/2024 | Lighting controls | WU(WOODY) CHEN | energy_progress |
| 05/02/2024 | Fire-Resistance Rated Construction | — | progress |
| 04/22/2024 | Energy Code Compliance Inspections | — | progress |
| 04/03/2024 | Final | JERE MURDOCH | progress |
| 03/27/2024 | Maintenance information | WU(WOODY) CHEN | energy_progress |
| 03/27/2024 | HVAC-R and service water piping design and insulation | WU(WOODY) CHEN | energy_progress |
| 03/27/2024 | HVAC-R and service water heating system controls | WU(WOODY) CHEN | energy_progress |
| 03/27/2024 | Fire-Resistant Penetrations and Joints | WU(WOODY) CHEN | special |
| 03/27/2024 | Lighting controls | WU(WOODY) CHEN | energy_progress |
| 03/27/2024 | Interior lighting power | WU(WOODY) CHEN | energy_progress |
| 03/27/2024 | Mechanical Systems | WU(WOODY) CHEN | special |
| 03/27/2024 | Energy Code Compliance Inspections | WU(WOODY) CHEN | progress |
| 03/27/2024 | Final | WU(WOODY) CHEN | progress |
| 03/27/2024 | Fire-Resistance Rated Construction | WU(WOODY) CHEN | progress |
| 03/27/2024 | Preliminary | WU(WOODY) CHEN | progress |
| 03/27/2024 | Maintenance information | WU(WOODY) CHEN | energy_progress |
| 03/27/2024 | HVAC-R and service water heating equipment | WU(WOODY) CHEN | energy_progress |
| 09/15/2021 | Maintenance information | WU(WOODY) CHEN | energy_progress |
| 09/15/2021 | Fire-Resistant Penetrations and Joints | WU(WOODY) CHEN | special |
| 09/13/2021 | Fire-Resistant Penetrations and Joints | WU(WOODY) CHEN | special |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| Popeyes | Restaurant / Food Service | Floor 1 | Project Q01030171 |