← Back
Two stories - detached, small or mid-size
120-56 132 STREET
QUEENS · BIN 4255015
💬 Discuss this project
1920Year Built
2Stories
A1Building Class
R3-2Zoning
1,488 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · Owner of record: RELIABLE CUSTOM BUILDERS, INC. · 4,600 sf lot · 0.32 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 213p · 1 filing · 20 docs
Floor 113p · 1 filing · 20 docs
Cellar16p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RELIABLE CUSTOM BUILDERS, INC.2407/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/19/2025$1.6M—— → —$1,075/sf building
02/18/2025$740K—— → —$497/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TABRIZ GROUP ENTERPRISES211/18/2025
TABRIZ DESIGN GROUP507/18/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RELIABLE CUSTOM BUILDERS*General Contractor804/09/2026
AYYUB ELECTRIC CORPElectrical203/22/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TABRIZ GROUP ENTERPRISES3275611/18/2025
HRF SERVICES CORP5616207/18/2025
Building Lifecycle
All (73)Filed (7)Permit Issued (5)Signed Off (4)Inspection (9)Objection (18)Special Inspection (30)
11/24/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/19/2025
Special inspection requirement — Maintenance information
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Interior lighting power
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Metering
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Permanent certificate
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Fenestration air leakage
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Electric vehicle service equipment requirements
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Insulation placement and R values
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Air barrier — testing
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Fenestration areas
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Air barrier - visual inspection
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
FAHAD FATEH
11/19/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Masonry
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Concrete - Cast-In-Place
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Energy Code Compliance Inspections
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Footing and Foundation
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Final
HARI SONI
11/19/2025
Special inspection requirement — Fire-Resistance Rated Construction
BAKHTIAR SHAMLOO
11/19/2025
Special inspection requirement — Structural Wood Frame
BAKHTIAR SHAMLOO
11/18/2025
Filed — Alteration CO
PROPOSED HORIZONTAL ENLARGEMENT, FULL INTERIOR & EXTERIOR RENOVATION, AND CONVERSION TO TWO FAMILY.
Q01190078-P1
11/18/2025
Special inspection requirement — Fenestration air leakage
BAKHTIAR SHAMLOO
11/18/2025
Special inspection requirement — Energy Code Compliance Inspections
BAKHTIAR SHAMLOO
11/18/2025
Special inspection requirement — Final
HARI SONI
11/18/2025
Special inspection requirement — Fire-Resistance Rated Construction
BAKHTIAR SHAMLOO
11/18/2025
Special inspection requirement — Footing and Foundation
BAKHTIAR SHAMLOO
11/18/2025
Special inspection requirement — Structural Wood Frame
BAKHTIAR SHAMLOO
11/18/2025
Special inspection requirement — Insulation placement and R values
BAKHTIAR SHAMLOO
11/18/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
BAKHTIAR SHAMLOO
10/23/2025
Signed off — Alteration
STRUCTURAL FRAMING AND PARTIAL DEMOLITION INCONJUNCTION WITH ALT CO APP# Q01190078-I1.
Q01194437-I1
10/23/2025
Signed off — Alteration
FOUNDATION APPLICATION IN CONJUNCTION WITH ALT CO APPLICATION Q01190078-I1.
Q01194427-I1
10/23/2025
Signed off — Alteration
PROPOSED PLUMBING WORK IN CONJUNCTION WITH APP#Q01190078-I1. (The 3-fixture bathroom statement is mentioned in the comment section of the Certificate of Occupancy as BB 2011-10 part (C. Filing)(b))
Q01217492-I1
10/21/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/14/2025
Permit issued — General Construction
Q01190078-I1-GC-CX
10/01/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
08/22/2025
Objection raised — Zoning
08/22/2025
Objection raised — Scope
08/22/2025
Objection raised — Structural
08/22/2025
Objection raised — Zoning
08/22/2025
Objection raised — Zoning
08/22/2025
Objection raised — Zoning
08/22/2025
Objection raised — Cost
08/22/2025
Objection raised — Admin
08/22/2025
Objection raised — Zoning
08/08/2025
Signed off — Alteration
TEMPORARY PLYWOOD CONSTRUCTION FENCE TO SECURE SITE FOR FUTURE CONSTRUCTION.
Q01183474-I1
08/08/2025
Filed — Alteration CO
PROPOSED HORIZONTAL ENLARGEMENT, FULL INTERIOR & EXTERIOR RENOVATION, AND CONVERSION TO TWO FAMILY.
Q01190078-I1
07/18/2025
Filed — Alteration
PROPOSED PLUMBING WORK IN CONJUNCTION WITH APP#Q01190078-I1. (The 3-fixture bathroom statement is mentioned in the comment section of the Certificate of Occupancy as BB 2011-10 part (C. Filing)(b))
Q01217492-P1
05/29/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/29/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
Latest 60 of 73 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedRELIABLE CUSTOM BUILDERS*10/14/2025
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR05/21/2025
DOB NOWStructuralSigned-offRELIABLE CUSTOM BUILDERS*05/05/2025
DOB NOWFoundationSigned-offRELIABLE CUSTOM BUILDERS*03/26/2025
DOB NOWConstruction FenceSigned-offRELIABLE CUSTOM BUILDERS*02/20/2025
BISOTISSUEDONFORCE SOLAR, INC09/28/2015
2 projects · most recent 08/28/2025
General Wiring
FiledStatusContractorScope
08/28/2025CompleteAYYUB ELECTRIC CORPGeneral Wiring
03/03/2025CompleteAYYUB ELECTRIC CORP—
1 project · most recent 11/18/2025
FiledStatusContractorScope
11/18/2025Permit IssuedRELIABLE CUSTOM BUILDERS*4 scope_items
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
11/24/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/21/2025Pass-Final CND-Occupancy InspectionPassView ↗
05/29/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/29/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
05/29/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/29/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/17/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/17/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/17/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 59
DateRequirementInspectorRole
11/19/2025Maintenance informationBAKHTIAR SHAMLOOenergy_progress
11/19/2025Interior lighting powerBAKHTIAR SHAMLOOenergy_progress
11/19/2025MeteringBAKHTIAR SHAMLOOenergy_progress
11/19/2025Permanent certificateBAKHTIAR SHAMLOOenergy_progress
11/19/2025Fenestration air leakageBAKHTIAR SHAMLOOenergy_progress
11/19/2025Electric vehicle service equipment requirementsBAKHTIAR SHAMLOOenergy_progress
11/19/2025Insulation placement and R valuesBAKHTIAR SHAMLOOenergy_progress
11/19/2025Fenestration and door U-factor and product ratingsBAKHTIAR SHAMLOOenergy_progress
11/19/2025Air barrier — testing BAKHTIAR SHAMLOOenergy_progress
11/19/2025Fenestration areasBAKHTIAR SHAMLOOenergy_progress
11/19/2025Air barrier - visual inspectionBAKHTIAR SHAMLOOenergy_progress
11/19/2025Excavations - Sheeting, Shoring, and BracingBAKHTIAR SHAMLOOspecial
11/19/2025Fire-Resistant Penetrations and JointsBAKHTIAR SHAMLOOspecial
11/19/2025Subsurface Investigations (Borings/Test Pits)FAHAD FATEHspecial
11/19/2025Structural Stability – Alterations of existing buildingsBAKHTIAR SHAMLOOspecial
11/19/2025MasonryBAKHTIAR SHAMLOOspecial
11/19/2025Concrete - Cast-In-PlaceBAKHTIAR SHAMLOOspecial
11/19/2025Energy Code Compliance InspectionsBAKHTIAR SHAMLOOprogress
11/19/2025Footing and FoundationBAKHTIAR SHAMLOOprogress
11/19/2025FinalHARI SONIprogress
11/19/2025Fire-Resistance Rated ConstructionBAKHTIAR SHAMLOOprogress
11/19/2025Structural Wood FrameBAKHTIAR SHAMLOOprogress
11/18/2025Fenestration air leakageBAKHTIAR SHAMLOOenergy_progress
11/18/2025Energy Code Compliance InspectionsBAKHTIAR SHAMLOOprogress
11/18/2025FinalHARI SONIprogress
Latest 25 of 59.
▾Documents — 81 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/20/2026Q01183474-I1Request digital key ↗
08/20/2026Q01194427-I1Request digital key ↗
08/20/2026Q01194437-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
09/17/2015440221582Open ↗
07/10/2015440221582Open ↗
▸BISWORK PERMIT APPLICATION1
09/28/2015440221582Open ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/13/2026Q01190078-I1Open ↗
08/13/2026Q01190078-P1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q01190078-P1Open ↗
08/13/2026Q01190078-I1Open ↗
▸Seals & Professional Certifications29
▸DOB NOWSpecial Inspector Seal & Signature11
08/28/2026Q01194437-I1Open ↗
08/27/2026Q01217492-P1Open ↗
08/27/2026Q01217492-P1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWProgress Inspector Seal & Signature10
08/28/2026Q01194437-I1Open ↗
08/28/2026Q01194437-I1Open ↗
08/26/2026Q01190078-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/20/2026Q01183474-I1Open ↗
08/20/2026Q01194437-I1Open ↗
08/20/2026Q01217492-P1Open ↗
Showing 3 of 7 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
09/08/2015440221582Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/13/2026Q01190078-I1Open ↗
08/13/2026Q01190078-P1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/20/2026Q01194437-I1Open ↗
08/20/2026Q01217492-I1Open ↗
08/20/2026Q01217492-P1Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/10/2015440221582Open ↗
▸Energy Compliance5
▸BISSOLAR TAX ABATEMENT APPLICATION2
12/01/2016440221582Open ↗
09/08/2015440221582Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
12/01/2016440221582Open ↗
09/08/2015440221582Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
12/01/2016440221582Open ↗
▸Inspections & Test Reports7
▸DOB NOWSOIL REPORT3
08/13/2026Q01190078-P1Open ↗
08/13/2026Q01194427-I1Open ↗
08/13/2026Q01190078-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY2
12/01/2016440221582Open ↗
09/08/2015440221582Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026Q01190078-I1Open ↗
08/13/2026Q01194427-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸BISThird Party Electrical Signoff Compliance Report1
12/01/2016440221582Open ↗
▸BISUtility Company PV System Interconnection Acknowledgement Letter1
12/01/2016440221582Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/01/2016440221582Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
12/01/2016440221582Open ↗
07/10/2015440221582Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
10/04/2016440221582Open ↗
09/10/2015440221582Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
07/10/2015440221582Open ↗
▸Other Documents9
▸DOB NOWSite Survey: Initial2
08/13/2026Q01190078-I1Open ↗
08/13/2026Q01190078-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q01190078-P1Open ↗
08/13/2026Q01190078-I1Open ↗
▸DOB NOWPlot Diagram2
08/13/2026Q01190078-I1Open ↗
08/13/2026Q01190078-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/13/2026Q01190078-I1Open ↗
08/13/2026Q01190078-P1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q01190078-I1Open ↗