ECB08/20/2026FAILURE TO MAINTAIN PARKING STRUCTURE INSAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED CONSISTING OF 4 LEVELS BELOW GRADE, OBSERVED SPALLED/CRACKED CONCRETE AT COLUMNS-BROKEN GLASS WINDOW AND LEA$2K due
ECB08/12/2026ATOI, OBSERVED DIAGONAL STEP CRACKS, MISSING MORTAR IN SOME OF THE BRICK JOINTS AND A SMALL BULGE AT EXPOSURE 4 (NORTH SIDE) OF INTERIOR SIDE DRIVEWAY WALL., MAINTAIN EXTERIOR BUILDING WALL; REPAIR WALL AND COR$5K due
ECB06/24/20263314.15.2 OBS SUSPENDED SCAFFOLD IN PLACE&READILY AVAILABLE FOR USE. STIRRUPS WERE INSTALLED APPROXIMATELY 2'-10B=" AND 2'-8" FROM THE ENDS OF THE PLATFORM, EXCEEDING ALLOWABLE LIMITS. STIRRUPS ARE REQUIRED TO$2K due
ECB06/23/20263307.4.7 OBS CONSTRUCTION MATERIALS, FENCE PANELS, PALLETS,&DEBRIS STORED WITHIN THE ROADWAY/WORK STORAGE ZONE ADJACENT TO THE PROJECT. MATERIALS WERE NOT PROPERLY SECURED, ENCLOSED, OR MAINTAINED IN AN ORDERLY$2K due
HPD03/11/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 67, 6th STORY, 3rd APARTMENT FROM SOUTH AT WEST
ECB09/04/2025OBSERVED OPPOSING TIEBACK ON SAME CONNECTION POINT,14 FT SINGLE PIECE I-BEAM DOES NOT SHOW ON THE APPROVED PLAN ,10 INCHES ANCHOR PLATES CONTRARY TO THE DESIGNED, DELTA BEAM CONNECTION MISSING BOLTS, THREE FEET$625 due
ECB09/04/2025OBSERVED CORNER ANGLE SCAFFOLD INSTALLED & IN USE WITH NO PRE INSPECTION BY THE DEPARTMENT OF BUILDINGS PRIOR TO USE OF CORNER ANGLE SCAFFOLD AS PER BC 3314.16.4 INSPECTION. THE EQUIPMENT SETTING FOR CORNER AND$2K due
HPD08/18/2025§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 77, 7th STORY, 2nd APARTMENT FROM WEST AT NORTH
ECB05/28/2025FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE:-AT THE TIME OF INSPECTION OBSERVED: CRACKED/SPALLING CONCRETE ABOVE THE MAIN ENTRANCE DOOR AT EXP #1. SPALLING CONCRETE AND LOOSE MATERIALS$25K due
ECB05/28/2025FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION OBSERVED CRACKED BRICK WITH OPEN MORTAR JOINY AT EXPO #1(13 FL). ALSO STEP CRACK AT EXPOSURE #2(13 FLOOR) WITH LOO$25K due
ECB03/06/20251RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103-09(E)(2) AND (5). TO DATE, THE DEPARTMENT HAS NOT RECIEVED A RETAINING WALL CONDITION ASSESS$1K due
ECB03/06/20251RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103-09(E)(2) AND (5). TO DATE, THE DEPARTMENT HAS NOT RECIEVED A RETAINING WALL CONDITION ASSESS$6K due
ECB03/06/20251RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103-09(E)(2) AND (5). TO DATE, THE DEPARTMENT HAS NOT RECIEVED A RETAINING WALL CONDITION ASSESS$6K due
ECB03/06/20251RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103-09(E)(2) AND (5). TO DATE, THE DEPARTMENT HAS NOT RECIEVED A RETAINING WALL CONDITION ASSESS$1K due
HPD09/17/2024§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 67, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH''
DOB12/15/2022FAILED TO FILE CYCLE 1 TECHNICAL REPORT BY 12/31/2018 PER RCNY 103-09
HPD05/15/2021§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
HPD05/15/2021§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY
HPD05/15/2021§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.
HPD05/15/2021§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORY
DOB03/18/2020THE BOROUGH COMMISSIONER INTENDS TO REVOKE ALL PLUMBING APPROVALS AND PERMIT IN CONNECTION WITH JOB #140831438 DUE TO REVOCATION OF LICENSE MASTER PLUMBER #1762 , ALL PLUMBING WORK IN CONNECTION WITH ABOVE MENTIONED PERMIT HAS ORDERED STOPPED IMMEDIATELY.
HPD12/18/2015SECTION 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY
DOB03/01/2013VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
DOB02/12/2012UNSAFE LOCAL LAW REPORT FILED
DOB01/19/2007V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
HPD09/28/1999SECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING 1 STY PUBLIC HALL.
HPD09/28/1999SECTION 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING.
HPD06/23/1999D26-10.01 ADM CODE REFIT OVEN DOOR OF GAS RANGE 8TH STY CENTER SOUTH APT 82 KITCHEN. , SECTION '' ''
HPD12/28/1993SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING 11 STY SOUTH APT 114 SOUTHEAST ROOM. , SECTION '' ''
HPD12/28/1993SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING 11 STY SOUTH APT 114 PRIVATE HALLWAY. , SECTION '' ''
HPD01/30/1985D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS 1ST STY WEST REAR WEST SECTION 111 MISSING.
HPD01/30/1985D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE STRIKE PLATE OF DOOR OF KITCHEN 9TH STY SOUTHEAST SECTION EAST APT 95. LOCATED AT APT 95
HPD01/30/1985D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERABLE WINDOWS ENTRANCE APT 9TH STY SOUTHEAST SECTION EAST APT 95. LOCATED AT APT 9TH
HPD01/30/1985D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS NORTHWEST ROOM AND CLOSET AT NORTHWEST ROOM REAR WEST SECTION 1ST STY WEST APT 111. LOCATED AT APT 111
HPD01/30/1985D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS 9TH STY SOUTHWEST SECTION EAST APT 95 MISSING. LOCATED AT APT 95
HPD01/30/1985D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING CAULKING AROUND OF KITCHEN SINK 9TH STY SOUTHEAST SECTIN EAST APT 95. LOCATED AT APT 95
HPD11/07/1983D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS 11TH STY WEST APT 111 AT SHOWER STALL WATER CLOSET COMPARTMENT NORTH WALL FOYER AND EAST WALL SOUTH ROOM. LOCATED AT APT 111
HPD11/07/1983D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DAMPNESS PENETRATING EAST WALL 9TH STY CENTER NORTH APT 94 FRONT EAST ROOM EAST WING. , SECTION '' ''
HPD11/07/1983D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DAMPNESS PENETRATING WEST WALL OF CLOTHES CLOSET 11TH STY WEST APT 111 REAR WEST ROOM. LOCATED AT APT 111
HPD11/07/1983D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CAULKING OF BATHTUB 11TH STY WEST APT 111 BATHROOM. LOCATED AT APT 111
ECB06/24/2026OBS INSTALLATION OF SUSPENDED SCAFFOLD NOT CONFORMING TO APPROVED CD5. MULTIPLE SUSPENSION LINES ATTACHED TO THE SAME ANCHOR POINT.MODULAR PLATFORMS REQUIRED BY APPROVED PLANS WERE NOT PROVIDED. PLATFORMS LACKEHearing held — result not yet published
ECB03/05/2026OBSERVE NO SUSPENDED SCAFFOLD IN PLACE IN CONNECTION WITH OUTRIGGER BEAMS AT ROOF LEVEL LOCATION WITH NO NOTIFICATION ON FILE. UPON FURTHER REVIEW OF THIS INTRANET AND DOB NOW. IT WAS REVEALED THAT NO NOTIFICATHearing held — result not yet published
ECB03/04/2026OBSERVE NO SUSPENDED SCAFFOLD IN PLACE IN USE & IN CONNECTION WITH OUTRIGGER BEAMS AT ROOF LOCATION WITH NO NOTIFICATION ON FILE. UPON FURTHER REVIEW OF BIS INTRANET AND DOB NOW. IT WAS REVEALED THAT NO NOTIFICHearing held — result not yet published
ECB05/15/2007SEC.CODE:26-234. FAILURE TO NOTIFY THE DEPT OF BLDGS IN WRITTING THAT A DANGEROUS & UNSAFE CONDITION EXISTED AT THE RETAINING WALL AT PREMI-SES. NOTED: WALL COLLAPSED ON 5/12/05. RESPONDENT WAS AWARE OF DANGER-Nothing owed — awaiting certificate of correction
ECB05/15/2007SEC.CODE:26-234. FAILURE TO NOTIFY THE DEPT OF BLDGS IN WRITTING THAT A DANGEROUS & UNSAFE CONDITION EXISTED AT THE RETAINING WALL AT PREMI-SES. NOTED: WALL COLLAPSED ON 5/12/05. RESPONDENT WAS AWARE OF DANGER-Nothing owed — awaiting certificate of correction
ECB05/15/2007SEC.CODE:26-234. FAILURE TO NOTIFY THE DEPT OF BLDGS IN WRITTING THAT A DANGEROUS & UNSAFE CONDITION EXISTED AT THE RETAINING WALL AT PREMI-SES. NOTED: WALL COLLAPSED ON 5/12/05. RESPONDENT WAS AWARE OF DANGER-Nothing owed — awaiting certificate of correction
ECB05/07/2006FAILURE TO MAINTAIN. DEFECTS NOTED:AT REAR OF PREMISES RETAINING WALL HAS SEVERAL DIAGONAL CRACKS,MISSING MORTAR JOINTS. PARAPET WALL ON RETAINING WALL HAS DISPLACEMENT OF CAPSTONE COLUMNS HAS CRACKS & REBARSNothing owed — awaiting certificate of correction
ECB05/14/2005FAILURE TO MAINTAIN EXTERIOR RUBBLE RETAINING WALL.NOTE:AT WEST END OF LOT(S) EXIST A 6 STORY 2 TIER RUBBLE RETAINING WALL THAT HAS PARTIALLY COLLAPSED DOWN INTO STREETS BELOW.REMEDY:MAKE SAFE IMMEDIATELY!PROVINothing owed — awaiting certificate of correction