← Back
Elevator apt, fireproof without stores
Park Avenue East
120 EAST 123RD STREET · East Harlem (North) · BIN 1054420
💬 Discuss this project
1970Year Built
6Stories
D3Building Class
R7BZoning
43,026 sfGross Floor Area
36Units
LL97 CoveredRent Stabilized19 Open Violations ▸FISP: SAFE
Elevator apt, fireproof without stores · Owner of record: PACT RENAISSANCE COLLABORATIVE LLC · 16,904 sf lot · 2.55 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbingEquipmentGeneral
Roof21p · 1 filing · 20 docs
Floor 620p · 2 filings · 20 docs
Floor 520p · 2 filings · 20 docs
Floor 421p · 2 filings · 20 docs
Floor 321p · 2 filings · 20 docs
Floor 227p · 2 filings · 20 docs
Floor 124p · 1 filing · 20 docs
Cellar28p · 3 filings · 20 docs
Site & exterior7p · 2 filings · 6 docs
Filed — no permit issued6p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
M BHUIYAN CONSTRUCTION C903/21/2026
NYC Housing Authority603/21/2026
KAJ NY CONSTRUCTION407/08/2026
NYCHA303/21/2026
NEW YORK CITY HOUSING AUTHORITY203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DAGHER ENGINEERING PLLC1811/22/2024
SYED ENGINEERING, P.C.210/11/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.3603/21/2026
CONSOLIDATED SCAFFOLD BRIDGE203/21/2026
ADVANCED BUILDERS SERVICES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DUAL FUEL PLUBING & HTINGPlumbing807/08/2026
DUAL FUEL COMPANY LLCGeneral Contractor407/08/2026
PYRAMID ETC COMPANIES, LLGeneral Contractor303/21/2026
CONSOLIDATED SCAFFOLDINGGeneral Contractor204/09/2026
WRUBEL, CHAIMElectrical103/21/2026
A & E PLUMBING CORPPlumbing107/08/2026
MORALES, RICHARDElectrical103/21/2026
KAJ NY CONSTRUCTION INCGeneral Contractor107/08/2026
INGLESE, PASQUALEElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M. HAMDI GUNAL, PE, P.C.30001303/20/2024
Building Lifecycle
All (153)Filed (20)Permit Issued (15)Signed Off (6)Facade (FISP) (15)Violation (60)Inspection (7)Special Inspection (30)
07/26/2026
Violation issued (HPD, open)
B
07/26/2026
Violation issued (HPD, open)
C
07/26/2026
Violation issued (HPD, open)
B
07/26/2026
Violation issued (HPD, open)
B
07/26/2026
Violation issued (HPD, closed)
C
07/08/2026
Violation issued (HPD, closed)
C
07/08/2026
Violation issued (HPD, closed)
C
07/08/2026
Violation issued (HPD, open)
A
07/08/2026
Violation issued (HPD, open)
A
07/04/2026
Violation issued (HPD, closed)
C
06/30/2026
Violation issued (HPD, open)
B
06/30/2026
Violation issued (HPD, open)
B
06/30/2026
Violation issued (HPD, open)
B
06/30/2026
Violation issued (HPD, open)
B
05/27/2026
Violation issued (HPD, closed)
B
04/29/2026
Violation issued (HPD, closed)
B
04/29/2026
Violation issued (HPD, closed)
C
04/29/2026
Violation issued (HPD, closed)
B
03/20/2026
Violation issued (HPD, closed)
C
03/20/2026
Violation issued (HPD, closed)
C
03/20/2026
Violation issued (HPD, closed)
C
03/20/2026
Violation issued (HPD, closed)
C
01/27/2026
Signed off — Alteration
TEMPORARY INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER DRAWINGS DURING GENERAL CONSTRUCTION WORK . NO CHANGE IN USE, EGRESS, AND OCCUPANCY. SIDEWALK SHED TO COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE OF 2014.
M00607839-I1
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/01/2025
Violation issued (HPD, closed)
B
04/01/2025
Violation issued (HPD, closed)
B
04/01/2025
Violation issued (HPD, closed)
B
04/01/2025
Violation issued (HPD, closed)
B
04/01/2025
Violation issued (HPD, closed)
B
12/12/2024
Signed off — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH RENOVATION FILED UNDER DOB #140957230. REPLACE PLUMBING FIXTURES ON EXISTING ROUGHING. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M00546321-I1
11/22/2024
Filed — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH RENOVATION FILED UNDER DOB #140957230. REPLACE PLUMBING FIXTURES ON EXISTING ROUGHING. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M00546321-P4
11/22/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Mehmet Gunal
11/21/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Mehmet Gunal
11/18/2024
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
10/11/2024
Violation issued (HPD, closed)
A
10/11/2024
Violation issued (HPD, closed)
B
10/11/2024
Violation issued (HPD, closed)
B
10/11/2024
Violation issued (HPD, closed)
B
09/25/2024
Filed — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH RENOVATION FILED UNDER DOB #140957230. REPLACE PLUMBING FIXTURES ON EXISTING ROUGHING. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M00546321-P3
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/20/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Mehmet Gunal
07/10/2024
Violation issued (HPD, closed)
C
07/10/2024
Violation issued (HPD, closed)
B
07/10/2024
Violation issued (HPD, closed)
C
07/03/2024
Signed off — Alteration
Boiler work as per plans filed.
M00382985-I1
07/03/2024
Signed off — Alteration
Plumbing work as per plans filed..
M00324178-I1
06/18/2024
Violation issued (HPD, closed)
C
06/18/2024
Violation issued (HPD, closed)
B
05/31/2024
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
05/30/2024
Permit issued — Boiler Equipment
M00382985-I1-BE
05/15/2024
Violation issued (HPD, closed)
C
05/15/2024
Violation issued (HPD, closed)
B
05/15/2024
Violation issued (HPD, closed)
A
03/21/2024
Cycle 9 facade report signed — SAFE
03/20/2024
Filed — Alteration
Plumbing work as per plans filed..
M00324178-P6
03/20/2024
Special inspection requirement — Energy Code Compliance Inspections
Mehmet Gunal
Latest 60 of 153 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentSigned-offDUAL FUEL PLUBING & HTING05/30/2024
DOB NOWPlumbingSigned-offA & E PLUMBING CORP02/20/2024
DOB NOWPlumbingSigned-offDUAL FUEL PLUBING & HTING02/13/2024
DOB NOWMechanical SystemsSigned-offPYRAMID ETC COMPANIES, LL11/27/2023
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING10/04/2022
DOB NOWBoiler EquipmentSigned-offDUAL FUEL PLUBING & HTING09/30/2022
DOB NOWPlumbingSigned-offDUAL FUEL PLUBING & HTING09/30/2022
DOB NOWSupported ScaffoldPermit IssuedKAJ NY CONSTRUCTION INC01/06/2022
DOB NOWMechanical SystemsSigned-offDUAL FUEL COMPANY LLC11/16/2021
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING10/13/2021
DOB NOWBoiler EquipmentSigned-offDUAL FUEL PLUBING & HTING09/21/2021
DOB NOWPlumbingSigned-offDUAL FUEL PLUBING & HTING09/21/2021
DOB NOWMechanical SystemsSigned-offDUAL FUEL COMPANY LLC08/13/2021
DOB NOWPlumbingSigned-offDUAL FUEL PLUBING & HTING08/05/2021
DOB NOWBoiler EquipmentSigned-offDUAL FUEL PLUBING & HTING06/29/2021
BISOTISSUEDPYRAMID ETC COMPANIES, LL11/08/2023
BISOTISSUEDMONADNOCK CONSTRUCTION IN11/07/2023
BISOTISSUEDMONADNOCK CONSTRUCTION IN11/17/2022
BISOTISSUEDPYRAMID ETC COMPANIES, LL06/29/2022
BISOTISSUEDMONADNOCK CONSTRUCTION IN02/04/2022
BISOTISSUEDPYRAMID ETC COMPANIES, LL10/05/2021
BISEQISSUEDM. BHUIYAN CONSTRUCTION CO.04/14/2016
BISEQISSUEDM. BHUIYAN CONSTRUCTION CO.04/12/2016
BISEQISSUEDM. BHUIYAN CONSTRUCTION CO.04/12/2016
BISOTISSUEDM. BHUIYAN CONSTRUCTION CO.04/12/2016
BISOTISSUEDM. BHUIYAN CONSTRUCTION CO.06/10/2015
BISOTISSUEDM. BHUIYAN CONSTRUCTION CO.06/03/2015
BISEQISSUEDM. BHUIYAN CONSTRUCTION CO.05/14/2015
BISEQISSUEDM. BHUIYAN CONSTRUCTION CO.05/12/2015
BISEQISSUEDM. BHUIYAN CONSTRUCTION CO.05/07/2015
BISEQISSUEDPIONEER GENERAL CONSTRUCT03/01/2007
BISEQISSUEDDAFFODIL GENE CONTR.09/23/2003
BISEQISSUEDLILLY CONSTRUCTION CO INC08/02/2002
BISFSISSUEDEFFICIENT COMB&COOLING CO04/26/2000
BISFSISSUEDEFFICIENT COMB&COOLING CO12/28/1999
BISPLRE-ISSUEDMAXIMUM MECHANICAL CORP06/11/1999
BISOTISSUEDANTHONY PATANE06/11/1999
BISPLISSUEDNATIONWIDE MECHANICAL INC08/04/1998
BISOTRE-ISSUEDSSN GENERAL CONSTRUCTION CORP08/04/1998
4 projects · most recent 11/16/2021
Boiler Controls
FiledStatusContractorScope
11/16/2021CompleteITKIN ELECTRIC CORP.Boiler Controls
10/18/2021Permit IssuedSTAR ELEC'L CONTRACTORS C—
10/08/2021CompleteV. VASS ELECTRIC CORP—
08/04/2021Permit IssuedROBERT CHIMENTI2 meters, 1 new_meters
1 project · most recent 10/11/2021
Scaffold
FiledStatusContractorScope
10/11/2021Permit IssuedKAJ NY CONSTRUCTION INCScaffold
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
11/18/2024Pass-Final PL - Up to 9 Requested FloorsPassView ↗
05/31/2024Pass-Final Boiler Equipment InspectionPassView ↗
03/01/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/01/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/21/2024No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
08/31/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/07/2023Fail-Final Boiler Equipment InspectionFailView ↗
▾Special Inspection Requirements (DOB NOW) — 52
DateRequirementInspectorRole
11/22/2024HVAC-R and service water piping design and insulationMehmet Gunalenergy_progress
11/21/2024HVAC-R and service water piping design and insulationMehmet Gunalenergy_progress
09/20/2024HVAC-R and service water piping design and insulationMehmet Gunalenergy_progress
03/20/2024Energy Code Compliance InspectionsMehmet Gunalprogress
03/20/2024HVAC insulation and sealing Mehmet Gunalenergy_progress
03/20/2024Fire-Resistant Penetrations and JointsMehmet Gunalspecial
03/20/2024Maintenance informationMehmet Gunalenergy_progress
02/06/2024Maintenance informationMehmet Gunalenergy_progress
02/06/2024HVAC insulation and sealing Mehmet Gunalenergy_progress
02/06/2024Fire-Resistant Penetrations and JointsMehmet Gunalspecial
02/06/2024Energy Code Compliance InspectionsMehmet Gunalprogress
01/29/2024HVAC and service water heating system controls Mehmet Gunalenergy_progress
01/29/2024Maintenance informationMehmet Gunalenergy_progress
01/29/2024HVAC and service water heating equipment Mehmet Gunalenergy_progress
01/29/2024Fire-Resistant Penetrations and JointsMehmet Gunalspecial
01/29/2024Heating SystemsMehmet Gunalspecial
01/24/2024HVAC-R and service water piping design and insulationMehmet Gunalenergy_progress
01/08/2024HVAC-R and service water piping design and insulationMehmet Gunalenergy_progress
09/05/2023HVAC and service water heating equipment Mehmet Gunalenergy_progress
09/05/2023Fire-Resistant Penetrations and JointsMehmet Gunalspecial
09/05/2023Heating SystemsMehmet Gunalspecial
09/05/2023HVAC and service water heating system controls Mehmet Gunalenergy_progress
09/05/2023Maintenance informationMehmet Gunalenergy_progress
09/05/2023Fire-Resistant Penetrations and JointsMehmet Gunalspecial
09/05/2023Energy Code Compliance InspectionsMehmet Gunalprogress
Latest 25 of 52.
▾Documents — 290 on file (BIS + DOB NOW)
▸Plans & Drawings20
▸DOB NOWPlans/Sketch9
09/03/2026M00519104-I1Request digital key ↗
09/03/2026M00549193-I1Request digital key ↗
09/03/2026M00607839-I1Request digital key ↗
Showing 3 of 9 on file for this type
▸DOB NOWPlans/Sketch - Plumbing7
08/29/2026M00324178-P6Request digital key ↗
08/29/2026M00324178-P5Request digital key ↗
08/29/2026M00324178-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸DOB NOWPlans/Sketch - Boiler Equipment3
09/04/2026M00382985-P2Request digital key ↗
09/04/2026M00382985-I1Request digital key ↗
09/04/2026M00382985-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/04/2026M00393677-I1Request digital key ↗
▸Applications & Permits32
▸BISPLAN / WORK APPROVAL APPLICATION19
05/24/2023140957230Open ↗
05/23/2023140957230Open ↗
07/13/2021140957230Open ↗
Showing 3 of 19 on file for this type
▸BISWORK PERMIT APPLICATION12
11/08/2023140967862Open ↗
02/04/2022140957230Open ↗
10/05/2021140962849Open ↗
Showing 3 of 12 on file for this type
▸BISAFTER-HOUR WORK PERMIT APPLICATION1
05/09/2017140168501Open ↗
▸Seals & Professional Certifications103
▸DOB NOWProgress Inspector Seal & Signature37
09/23/2026M00382985-I1Open ↗
09/23/2026M00382985-I1Open ↗
09/23/2026M00382985-I1Open ↗
Showing 3 of 37 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature20
09/04/2026M00382985-P1Open ↗
09/04/2026M00382985-P2Open ↗
09/04/2026M00382985-I1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature15
09/23/2026M00382985-I1Open ↗
09/23/2026M00382985-I1Open ↗
09/02/2026M00324178-P1Open ↗
Showing 3 of 15 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION11
05/23/2017140344367Open ↗
05/09/2017140168501Open ↗
05/09/2017140168501Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY7
10/23/2020140967862Open ↗
10/08/2020140962849Open ↗
09/24/2020140957230Open ↗
Showing 3 of 7 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION6
10/08/2020140962849Open ↗
09/24/2020140957230Open ↗
05/09/2015140345838Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT6
10/08/2020140962849Open ↗
09/24/2020140957230Open ↗
05/09/2015140345838Open ↗
Showing 3 of 6 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
10/23/2020140967862Open ↗
▸Safety & Tenant Protection14
▸DOB NOWTenant Protection Plan11
09/04/2026M00382985-I1Open ↗
09/04/2026M00382985-P2Open ↗
09/04/2026M00382985-P1Open ↗
Showing 3 of 11 on file for this type
▸BISTENANT PROTECTION PLAN AND NOTES3
10/23/2020140967862Open ↗
10/08/2020140962849Open ↗
09/24/2020140957230Open ↗
▸Environmental & Asbestos15
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/28/2026M00546321-P3Open ↗
08/28/2026M00546321-P2Open ↗
08/28/2026M00546321-P1Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)4
02/04/2022140957230Open ↗
10/01/2021140962849Open ↗
05/09/2017140168501Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form3
09/04/2026M00382985-I1Open ↗
08/13/2026M00393677-I1Open ↗
08/13/2026M00324178-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/07/2015140344839Open ↗
▸Energy Compliance27
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY12
02/01/2024140967862Open ↗
02/01/2024140957230Open ↗
01/23/2024140967862Open ↗
Showing 3 of 12 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS4
10/23/2020140967862Open ↗
10/08/2020140962849Open ↗
09/24/2020140957230Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS (EN2)3
01/23/2024140967862Open ↗
01/23/2024140957230Open ↗
03/30/2023140962849Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS2
11/08/2023140967862Open ↗
03/30/2023140962849Open ↗
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026M00519104-I1Open ↗
08/13/2026M00546321-I1Open ↗
▸BISNYCECC ANALYSIS1
03/19/2014140168501Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
05/09/2017140168501Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/09/2017140168501Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
09/04/2026M00382985-I1Open ↗
▸Inspections & Test Reports22
▸BISTECHNICAL REPORT: RESPONSIBILITY17
02/01/2024140967862Open ↗
02/01/2024140957230Open ↗
01/23/2024140967862Open ↗
Showing 3 of 17 on file for this type
▸BISCONCRETE - CAST-IN-PLACE1
11/08/2023140967862Open ↗
▸BISSTRUCTURAL STEEL - HIGH STRENGTH BOLTING1
03/30/2023140962849Open ↗
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS1
03/30/2023140962849Open ↗
▸BISMASONRY1
03/30/2023140962849Open ↗
▸BISSTRUCTURAL STEEL - DETAILS1
03/30/2023140962849Open ↗
▸Approvals, Objections & Sign-offs34
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter18
09/04/2026M00382985-P1Open ↗
09/04/2026M00382985-P2Open ↗
09/04/2026M00382985-I1Open ↗
Showing 3 of 18 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST7
02/01/2024140967862Open ↗
02/01/2024140957230Open ↗
03/31/2023140962849Open ↗
Showing 3 of 7 on file for this type
▸BISFINAL3
01/23/2024140957230Open ↗
11/08/2023140967862Open ↗
03/30/2023140962849Open ↗
▸BISDESIGN COMM. APPROVAL: CITY-OWNED PROPERTY (EXTERIOR WORK)2
10/08/2020140962849Open ↗
09/24/2020140957230Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
05/09/2017140168501Open ↗
▸BISSHED LETTER1
04/28/2016140344367Open ↗
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)1
08/13/2026M00609156-I1Open ↗
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)1
08/13/2026M00609156-I1Open ↗
▸Cost, Insurance & Ownership8
▸BISCOST AFFIDAVIT5
10/23/2020140967862Open ↗
10/08/2020140962849Open ↗
09/24/2020140957230Open ↗
Showing 3 of 5 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW33
01/23/2024140967862Open ↗
01/23/2024140957230Open ↗
03/30/2023140962849Open ↗
▸Filing & Intake Forms12
▸BISEFILING JOB APPLICATION COVER SHEET7
10/23/2020140967862Open ↗
10/08/2020140962849Open ↗
09/24/2020140957230Open ↗
Showing 3 of 7 on file for this type
▸BISADDITIONAL INFORMATION5
05/24/2023140957230Open ↗
07/13/2021140957230Open ↗
10/23/2020140967862Open ↗
Showing 3 of 5 on file for this type
▸Other Documents3
▸BISFEE EXEMPTION DOCUMENTATION2
10/08/2020140962849Open ↗
09/24/2020140957230Open ↗
▸BISVERIFY DOB PLAN NAMING STANDARD IS MET1
05/06/2015140344367Open ↗