← Back
Two family frame
1208 VYSE AVENUE
BRONX · Crotona Park East · BIN 2099936
💬 Discuss this project
1991Year Built
3Stories
B2Building Class
R7-1Zoning
2,100 sfGross Floor Area
2Units
Two family frame · 2,000 sf lot · 1.05 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
N Y C PTNRSHP HSNG DEV FUND103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC105/01/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNCO CAPITAL LLCGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854105/01/2025
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
08/11/2025
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01218959-I1
05/23/2025
Permit issued — Solar
X01218959-I1-SL
05/01/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01218959-I1
04/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
04/30/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
04/30/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
04/30/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
04/30/2025
Special inspection requirement — Final
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNCO CAPITAL LLC05/23/2025
BIS—ISSUEDCASBRO CONSTRUCTION CORP08/03/1992
BIS—ISSUEDCASBRO CONSTRUCTION CORP11/19/1991
BISPLISSUEDMEDCO PLUMBING INC11/12/1991
BIS—ISSUEDDELUXE DEVELOPMENT OF N.Y.INC.04/19/1991
1 project · most recent 04/30/2025
FiledStatusContractorScope
04/30/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/30/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
04/30/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
04/30/2025Energy Code Compliance InspectionsTOM PETERSENprogress
04/30/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
04/30/2025FinalTOM PETERSENprogress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/19/2026X01218959-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026X01218959-I1Open ↗
09/01/2026X01218959-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026X01218959-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026X01218959-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01218959-I1Open ↗