← Back
Two stories - detached, small or mid-size
1209 BRYANT AVENUE
BRONX · BIN 2010713
💬 Discuss this project
1920Year Built
2Stories
A1Building Class
R7-1Zoning
1,298 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸
Two stories - detached, small or mid-size · Owner of record: BST MANAGEMENT NY LLC · 2,000 sf lot · 0.65 FAR built · Flood zone X
Locations of Work
Architecture
Floor 211p · 2 filings · 20 docs
Floor 110p · 2 filings · 20 docs
Cellar5p · 1 filing · 4 docs
Basement10p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
JS HOMES REALTY SERVICES INC.1207/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/31/2025$360K—Private party → BST MANAGEMENT NY LLC$277/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARQUITECTURA VARELA504/10/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CM3 DESIGN STUDIO303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JS HOMES REALTY SERVICESGeneral Contractor307/08/2026
WCK ELECTRIC CORP.Electrical103/22/2026
CAPE PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WORLD DESIGN ARCHITECTURE9323103/20/2025
Building Lifecycle
All (45)Filed (5)Permit Issued (4)Signed Off (1)Violation (1)Inspection (4)Objection (8)Special Inspection (22)
07/24/2026
Signed off — Alteration CO
Application to convert existing single family into two class A dwelliing residential building.
X01233076-S1
05/28/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/28/2026
Special inspection requirement — Metering
Vicente Varela
04/28/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Vicente Varela
04/28/2026
Special inspection requirement — Interior lighting power
Vicente Varela
04/28/2026
Special inspection requirement — Insulation placement and R values
Vicente Varela
04/28/2026
Special inspection requirement — Air barrier - visual inspection
Vicente Varela
04/28/2026
Special inspection requirement — Fenestration areas
Vicente Varela
04/28/2026
Special inspection requirement — Fenestration air leakage
Vicente Varela
04/27/2026
Special inspection requirement — Maintenance information
Vicente Varela
04/27/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Vicente Varela
04/27/2026
Special inspection requirement — HVAC-R and service water heating equipment
Vicente Varela
04/27/2026
Special inspection requirement — HVAC-R and service water heating system controls
Vicente Varela
04/10/2026
Filed — Alteration CO
Application to convert existing single family into two class A dwelliing residential building.
X01233076-P2
04/10/2026
Objection resolved — Resolved
04/02/2026
Objection raised — Scope
03/31/2026
Special inspection requirement — Maintenance information
Vicente Varela
03/31/2026
Special inspection requirement — HVAC-R and service water heating equipment
Vicente Varela
03/31/2026
Special inspection requirement — HVAC-R and service water heating system controls
Vicente Varela
03/31/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Vicente Varela
03/26/2026
Filed — Alteration CO
Application to convert existing single family into two class A dwelliing residential building.
X01233076-P1
03/16/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/16/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/16/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/24/2026
Permit issued — General Construction
X01233076-I1-GC
02/23/2026
Special inspection requirement — Interior lighting power
Vicente Varela
02/23/2026
Special inspection requirement — Insulation placement and R values
Vicente Varela
02/23/2026
Special inspection requirement — Air barrier - visual inspection
Vicente Varela
02/23/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Vicente Varela
02/23/2026
Special inspection requirement — Metering
Vicente Varela
02/23/2026
Special inspection requirement — Fenestration areas
Vicente Varela
02/23/2026
Special inspection requirement — Fenestration air leakage
Vicente Varela
12/17/2025
Permit issued — Plumbing
X01233076-S1-PL
11/14/2025
Objection resolved — Addressed
11/10/2025
Objection raised — Energy
10/30/2025
Filed — Alteration CO
Application to convert existing single family into two class A dwelliing residential building.
X01233076-S1
10/24/2025
Objection resolved — Addressed
09/07/2025
Objection resolved — Addressed
08/26/2025
Objection raised — Structural
08/26/2025
Objection raised — Fire_Protection
08/19/2025
Permit issued — General Construction
X01197878-I1-GC
08/11/2025
Filed — Alteration CO
Application to convert existing single family into two class A dwelliing residential building.
X01233076-I1
03/27/2025
Permit issued — General Construction
X01197878-I1-GC
03/20/2025
Filed — Alteration
Interior renovation and proposed horirontal enlargement of existing 3 three story residential building. No change of use, occupancy or egress under this application.
X01197878-I1
05/03/2000
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedJS HOMES REALTY SERVICES02/24/2026
DOB NOWPlumbingSigned-offCAPE PLUMBING INC12/17/2025
DOB NOWGeneral ConstructionPermit IssuedJS HOMES REALTY SERVICES08/19/2025
DOB NOWGeneral ConstructionPermit IssuedJS HOMES REALTY SERVICES03/27/2025
1 project · most recent 04/10/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/10/2026Signed-offCAPE PLUMBING INCGas, Water/Sanitary
1 project · most recent 06/24/2026
General Wiring
FiledStatusContractorScope
06/24/2026CompleteWCK ELECTRIC CORP.General Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
05/28/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/16/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/16/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/16/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
04/28/2026MeteringVicente Varelaenergy_progress
04/28/2026Fenestration and door U-factor and product ratingsVicente Varelaenergy_progress
04/28/2026Interior lighting powerVicente Varelaenergy_progress
04/28/2026Insulation placement and R valuesVicente Varelaenergy_progress
04/28/2026Air barrier - visual inspectionVicente Varelaenergy_progress
04/28/2026Fenestration areasVicente Varelaenergy_progress
04/28/2026Fenestration air leakageVicente Varelaenergy_progress
04/27/2026Maintenance informationVicente Varelaenergy_progress
04/27/2026HVAC-R and service water piping design and insulationVicente Varelaenergy_progress
04/27/2026HVAC-R and service water heating equipmentVicente Varelaenergy_progress
04/27/2026HVAC-R and service water heating system controlsVicente Varelaenergy_progress
03/31/2026Maintenance informationVicente Varelaenergy_progress
03/31/2026HVAC-R and service water heating equipmentVicente Varelaenergy_progress
03/31/2026HVAC-R and service water heating system controlsVicente Varelaenergy_progress
03/31/2026HVAC-R and service water piping design and insulationVicente Varelaenergy_progress
02/23/2026Interior lighting powerVicente Varelaenergy_progress
02/23/2026Insulation placement and R valuesVicente Varelaenergy_progress
02/23/2026Air barrier - visual inspectionVicente Varelaenergy_progress
02/23/2026Fenestration and door U-factor and product ratingsVicente Varelaenergy_progress
02/23/2026MeteringVicente Varelaenergy_progress
02/23/2026Fenestration areasVicente Varelaenergy_progress
02/23/2026Fenestration air leakageVicente Varelaenergy_progress
▾Documents — 46 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/19/2026X01197878-I1Request digital key ↗
08/17/2026X01233076-P2Request digital key ↗
08/17/2026X01233076-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications27
▸DOB NOWProgress Inspector Seal & Signature22
08/31/2026X01233076-P1Open ↗
08/31/2026X01233076-P1Open ↗
08/31/2026X01233076-P1Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/17/2026X01233076-P2Open ↗
08/17/2026X01233076-P1Open ↗
08/17/2026X01233076-S1Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist2
08/13/2026X01233076-I1Open ↗
08/13/2026X01233076-P1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/17/2026X01233076-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/17/2026X01233076-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X01233076-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/17/2026X01233076-P2Open ↗
08/17/2026X01233076-P1Open ↗
08/17/2026X01233076-S1Open ↗
Showing 3 of 5 on file for this type
▸Other Documents4
▸DOB NOWProperty Ownership Certification2
08/17/2026X01233076-P1Open ↗
08/17/2026X01233076-I1Open ↗
▸DOB NOWFinal Survey1
08/17/2026X01233076-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1