← Back
Two family frame
121-11 8 AVENUE
QUEENS · BIN 4096275
💬 Discuss this project
1930Year Built
2Stories
B2Building Class
R3AZoning
1,760 sfGross Floor Area
2Units
0 Open Violations
Two family frame · 2,500 sf lot · 0.7 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Roof2p · 1 filing · 9 docs
Basement1p · 1 filing · 9 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC105/01/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BERGER QUALITY ELEC'L CONElectrical103/22/2026
KAMTECH RESTORATION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802105/01/2024
Building Lifecycle
All (9)Filed (1)Permit Issued (1)Signed Off (1)Violation (1)Special Inspection (5)
05/28/2026
Signed off — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01044766-I1
05/03/2024
Permit issued — Solar
Q01044766-I1-SL
05/01/2024
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01044766-I1
05/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
05/01/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
05/01/2024
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
05/01/2024
Special inspection requirement — Final
Kaijin Liang
05/01/2024
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
09/19/2008
Violation issued (ECB, closed)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP05/03/2024
1 job · most recent 07/11/2024
FiledStatusContractorScope
07/11/2024CompleteBERGER QUALITY ELEC'L CON—
1 job · most recent 05/01/2024
FiledStatusContractorScope
05/01/2024Signed-offKAMTECH RESTORATION CORP18 panels, 7.56 kw, 1,182.37 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/01/2024Fire-Resistant Penetrations and JointsKaijin Liangspecial
05/01/2024Structural Stability – Alterations of existing buildingsKaijin Liangspecial
05/01/2024Energy Code Compliance InspectionsKaijin Liangprogress
05/01/2024FinalKaijin Liangprogress
05/01/2024Air barrier - visual inspectionKaijin Liangenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026Q01044766-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/30/2026Q01044766-I1Open ↗
08/30/2026Q01044766-I1Open ↗
08/30/2026Q01044766-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026Q01044766-I1Open ↗
08/30/2026Q01044766-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/22/2026Q01044766-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/22/2026Q01044766-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/22/2026Q01044766-I1Open ↗