← Back
Four families
121 PRESIDENT STREET
💬 Discuss this project
1920Year Built
3Stories
C3Building Class
R6BZoning
3,691 sfGross Floor Area
4Units
Rent Stabilized1 Open Violation ▸
Four families · 2,000 sf lot · 1.85 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 46p · 1 filing · 20 docs
Floor 36p · 1 filing · 20 docs
Floor 26p · 1 filing · 20 docs
Floor 16p · 1 filing · 20 docs
Cellar8p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/14/2025$2.8M—— → —$745/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DMYTRO CHORNOBRYVETS ARCHITECT,PLLC807/03/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DENI INTERNATIONAL INCGeneral Contractor104/08/2026
POP UP CONTRACTING, LLCGeneral Contractor107/08/2026
ARANDA PLBG & HTG CORPPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A&B WORLD CONSULTING, INC5704205/28/2026
Building Lifecycle
All (40)Filed (8)Permit Issued (3)Violation (8)Inspection (9)Special Inspection (12)
07/03/2026
Filed — Alteration
Plumbing work in conjunction with interior renovation on all floors and all 4 apartments. No change in use, occupancy and egress.
B01273007-P6
05/29/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Bomstein
05/29/2026
Special inspection requirement — Energy Code Compliance Inspections
Alexander Bomstein
05/29/2026
Special inspection requirement — Fire-Resistance Rated Construction
Alexander Bomstein
05/29/2026
Special inspection requirement — Final
DMYTRO CHORNOBRYVETS
05/29/2026
Special inspection requirement — Lighting in dwelling units
Alexander Bomstein
05/29/2026
Special inspection requirement — Lighting controls
Alexander Bomstein
05/29/2026
Special inspection requirement — Interior lighting power
Alexander Bomstein
05/29/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Alexander Bomstein
05/29/2026
Special inspection requirement — Fenestration areas
Alexander Bomstein
05/29/2026
Special inspection requirement — Air barrier - visual inspection
Alexander Bomstein
05/29/2026
Special inspection requirement — Exterior lighting power
Alexander Bomstein
05/29/2026
Special inspection requirement — Fenestration air leakage
Alexander Bomstein
05/28/2026
Filed — Alteration
Plumbing work in conjunction with interior renovation on all floors and all 4 apartments. No change in use, occupancy and egress.
B01273007-P4
05/28/2026
Filed — Alteration
Plumbing work in conjunction with interior renovation on all floors and all 4 apartments. No change in use, occupancy and egress.
B01273007-P5
05/05/2026
Violation issued (HPD, open)
A
05/04/2026
Filed — Alteration
Plumbing work in conjunction with interior renovation on all floors and all 4 apartments. No change in use, occupancy and egress.
B01273007-P3
03/18/2026
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
03/13/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
03/09/2026
Filed — Alteration
Plumbing work in conjunction with interior renovation on all floors and all 4 apartments. No change in use, occupancy and egress.
B01273007-P2
01/07/2026
Filed — Alteration
Plumbing work in conjunction with interior renovation on all floors and all 4 apartments. No change in use, occupancy and egress.
B01273007-P1
01/07/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/07/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/12/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/12/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/12/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/10/2025
Permit issued — General Construction
B01273007-I1-GC
10/03/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
10/01/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
09/25/2025
Permit issued — Plumbing
B01273007-S1-PL
09/18/2025
Permit issued — General Construction
B01273007-I1-GC
09/09/2025
Filed — Alteration
Plumbing work in conjunction with interior renovation on all floors and all 4 apartments. No change in use, occupancy and egress.
B01273007-S1
09/08/2025
Filed — Alteration
Plumbing work in conjunction with interior renovation on all floors and all 4 apartments. No change in use, occupancy and egress.
B01273007-I1
06/10/2025
Violation issued (HPD, closed)
A
04/11/2024
Violation issued (HPD, closed)
A
03/24/2023
Violation issued (HPD, closed)
A
03/01/2022
Violation issued (HPD, closed)
A
03/01/2022
Violation issued (HPD, closed)
I
04/12/2021
Violation issued (HPD, closed)
A
10/19/2018
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offDENI INTERNATIONAL INC10/10/2025
DOB NOWPlumbingPermit IssuedARANDA PLBG & HTG CORP09/25/2025
DOB NOWGeneral ConstructionSigned-offPOP UP CONTRACTING09/18/2025
1 project · most recent 07/03/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/03/2026Permit IssuedARANDA PLBG & HTG CORPGas, Water/Sanitary
1 project · most recent 10/01/2026
FiledStatusContractorScope
10/01/2026Permit IssuedBLUE SEAGULL ELECTRICAL5 meters, 5 new_meters
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
03/18/2026No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
03/13/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
01/07/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/07/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/12/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/12/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/12/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/03/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/01/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
05/29/2026Fire-Resistant Penetrations and JointsAlexander Bomsteinspecial
05/29/2026Energy Code Compliance InspectionsAlexander Bomsteinprogress
05/29/2026Fire-Resistance Rated ConstructionAlexander Bomsteinprogress
05/29/2026FinalDMYTRO CHORNOBRYVETSprogress
05/29/2026Lighting in dwelling unitsAlexander Bomsteinenergy_progress
05/29/2026Lighting controlsAlexander Bomsteinenergy_progress
05/29/2026Interior lighting powerAlexander Bomsteinenergy_progress
05/29/2026Fenestration and door U-factor and product ratingsAlexander Bomsteinenergy_progress
05/29/2026Fenestration areasAlexander Bomsteinenergy_progress
05/29/2026Air barrier - visual inspectionAlexander Bomsteinenergy_progress
05/29/2026Exterior lighting powerAlexander Bomsteinenergy_progress
05/29/2026Fenestration air leakageAlexander Bomsteinenergy_progress
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/17/2026B01273007-P3Request digital key ↗
08/17/2026B01273007-P2Request digital key ↗
08/17/2026B01273007-P1Request digital key ↗
Showing 3 of 8 on file for this type
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/17/2026B01273007-P1Open ↗
08/17/2026B01273007-S1Open ↗
08/17/2026B01273007-P4Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/27/2026B01273007-I1Open ↗
08/27/2026B01273007-I1Open ↗
08/27/2026B01273007-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026B01273007-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/17/2026B01273007-P1Open ↗
08/17/2026B01273007-P5Open ↗
08/17/2026B01273007-P4Open ↗
Showing 3 of 8 on file for this type