← Back
BuildNYC
Over six families without stores
121 WEST 144TH STREET
MANHATTAN · BIN 1060166
💬 Discuss this project
1910Year Built
5Stories
C1Building Class
R7-2Zoning
18,230 sfGross Floor Area
30Units
Rent Stabilized1 Active Violation ▸
Over six families without stores · Owner of record: West Harlem Renaissance Housing Developm Ent Fund · 5,304 sf lot · 3.44 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofInfinite Horizons TPT Cluster RehabilitationUnder Construction6p · 2 filings · 20 docs
BulkheadInfinite Horizons TPT Cluster RehabilitationUnder Construction1p · 1 filing · 20 docs
Floor 5Infinite Horizons TPT Cluster RehabilitationUnder Construction83p · 1 filing · 20 docs
Floor 4Infinite Horizons TPT Cluster RehabilitationUnder Construction75p · 1 filing · 20 docs
Floor 3Infinite Horizons TPT Cluster RehabilitationUnder Construction82p · 1 filing · 20 docs
Floor 2Infinite Horizons TPT Cluster RehabilitationUnder Construction82p · 1 filing · 20 docs
Floor 1Infinite Horizons TPT Cluster RehabilitationUnder Construction82p · 1 filing · 20 docs
CellarInfinite Horizons TPT Cluster RehabilitationUnder Construction87p · 1 filing · 20 docs
Site & exteriorInstallation of temporary pipe scaffold17p · 3 filings · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC Department of Housing Preservation and Development3307/08/2026
West Harlem Renaissance HDFC1010/07/2026
West Harlem Renaissance Housing Developm Ent Fund103/22/2026
NYC Department of Housing Pres. & Development103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Ocv Architects510/06/2026
Applied HVAC Engineering707/09/2025
Synergic Design Architects103/27/2025
Mje Professional Services104/29/2024
Rigid Structural Design101/23/2024
Ashraf101/16/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Ocv Architects1103/21/2026
Rigid Structural Design103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Apex Building CompanyGeneral Contractor1907/08/2026
Ips PlumbingPlumbing807/08/2026
WJ Professional ExpeditinGeneral Contractor704/09/2026
Reliable EnterprisesScaffold207/08/2026
Tristate Fire SprinklersFire Protection207/08/2026
4 Brothers & Sons FenceScaffold204/09/2026
BK Construction ServicesScaffold207/08/2026
Accord PowerGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Metric Consulting and Ins18031210/06/2026
Synergic Design8561103/27/2025
Building Lifecycle
All (170)Filed (16)Permit Issued (27)Signed Off (7)Violation (60)Inspection (6)Objection (24)Special Inspection (30)
10/06/2026
Filed — Alteration CO
INSTALLATION OF NEW HYDRO-KIT UNITS FOR DOMESTIC WATER HEATING AND INDOOR AHU'S WITH ROOF ACCU'S FOR SPACE HEATING. NEW ROOF TOP UNIT FOR VENTILATION OF COMMON AREAS, NEW CENTRAL KITCHEN AND BATHROOM EXHAUST FANS.
M00649549-P9
10/02/2026
Signed off — Alteration CO
INSTALLATION OF NEW HYDRO-KIT UNITS FOR DOMESTIC WATER HEATING AND INDOOR AHU'S WITH ROOF ACCU'S FOR SPACE HEATING. NEW ROOF TOP UNIT FOR VENTILATION OF COMMON AREAS, NEW CENTRAL KITCHEN AND BATHROOM EXHAUST FANS.
M00649549-S2
10/02/2026
Signed off — Alteration CO
INSTALLATION OF NEW HYDRO-KIT UNITS FOR DOMESTIC WATER HEATING AND INDOOR AHU'S WITH ROOF ACCU'S FOR SPACE HEATING. NEW ROOF TOP UNIT FOR VENTILATION OF COMMON AREAS, NEW CENTRAL KITCHEN AND BATHROOM EXHAUST FANS.
M00649549-S1
10/02/2026
Signed off — Alteration CO
INSTALLATION OF NEW HYDRO-KIT UNITS FOR DOMESTIC WATER HEATING AND INDOOR AHU'S WITH ROOF ACCU'S FOR SPACE HEATING. NEW ROOF TOP UNIT FOR VENTILATION OF COMMON AREAS, NEW CENTRAL KITCHEN AND BATHROOM EXHAUST FANS.
M00649549-S3
09/28/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Fenestration areas
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Exterior lighting power
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Fenestration air leakage
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Insulation placement and R values
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Lighting controls
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Energy Code Compliance Inspections
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Air barrier - visual inspection
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Fire-Resistance Rated Construction
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Interior lighting power
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
SAMI HAJJAR P.E
09/28/2026
Special inspection requirement — Lighting in dwelling units
SAMI HAJJAR P.E
05/06/2026
Violation issued (HPD, closed)
C
03/05/2026
Filed — Alteration CO
INSTALLATION OF NEW HYDRO-KIT UNITS FOR DOMESTIC WATER HEATING AND INDOOR AHU'S WITH ROOF ACCU'S FOR SPACE HEATING. NEW ROOF TOP UNIT FOR VENTILATION OF COMMON AREAS, NEW CENTRAL KITCHEN AND BATHROOM EXHAUST FANS.
M00649549-P8
02/27/2026
Special inspection requirement — Fenestration areas
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Interior lighting power
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Lighting in dwelling units
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Insulation placement and R values
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Air barrier - visual inspection
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Fire-Resistance Rated Construction
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Energy Code Compliance Inspections
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Exterior lighting power
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Fenestration air leakage
SAMI HAJJAR P.E
02/27/2026
Special inspection requirement — Lighting controls
SAMI HAJJAR P.E
01/15/2026
Permit issued — Structural
M00649549-S4-GC
01/13/2026
Permit issued — General Construction
M00649549-I1-GC
10/17/2025
Signed off — Alteration
M00991689-I1
08/19/2025
Signed off — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M01043134-I1
08/15/2025
Signed off — Alteration
Installation of 18.63 kw solar energy system on roof. No change of occupancy, use or egree
M01182367-I1
08/07/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
08/04/2025
Inspection — Certified Sprinkler (SP) - Booster Pump Test
Certified
View inspection ↗
08/04/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SAMI HAJJAR P.E
07/21/2025
Special inspection requirement — Sprinkler Systems
SAMI HAJJAR P.E
07/11/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/09/2025
Filed — Alteration CO
INSTALLATION OF NEW HYDRO-KIT UNITS FOR DOMESTIC WATER HEATING AND INDOOR AHU'S WITH ROOF ACCU'S FOR SPACE HEATING. NEW ROOF TOP UNIT FOR VENTILATION OF COMMON AREAS, NEW CENTRAL KITCHEN AND BATHROOM EXHAUST FANS.
M00649549-P7
06/27/2025
Signed off — Alteration
INSTALLATION OF 65' NEW SIDEWALK SHED AT 121 W 144th St AS INDICATED ON PLANS. THERE WILL BE NO CHANGE IN THE USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
M00988635-I1
06/16/2025
Special inspection requirement — Sprinkler Systems
SAMI HAJJAR P.E
06/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SAMI HAJJAR P.E
06/04/2025
Permit issued — Sprinklers
M00649549-S3-EW-SP
04/21/2025
Permit issued — Plumbing
M00649549-S2-PL
04/08/2025
Permit issued — Solar
M01182367-I1-SL
03/27/2025
Filed — Alteration
Installation of 18.63 kw solar energy system on roof. No change of occupancy, use or egree
M01182367-I1
02/19/2025
Permit issued — Supported Scaffold
M01043134-I1-SF
02/12/2025
Permit issued — Construction Fence
M00991689-I1-FN
01/22/2025
Permit issued — Sidewalk Shed
M00988635-I1-SH
01/17/2025
Filed — Alteration CO
INSTALLATION OF NEW HYDRO-KIT UNITS FOR DOMESTIC WATER HEATING AND INDOOR AHU'S WITH ROOF ACCU'S FOR SPACE HEATING. NEW ROOF TOP UNIT FOR VENTILATION OF COMMON AREAS, NEW CENTRAL KITCHEN AND BATHROOM EXHAUST FANS.
M00649549-P6
01/15/2025
Permit issued — General Construction
M00649549-S4-ST
01/15/2025
Permit issued — Mechanical Systems
M00649549-S1-MS
01/15/2025
Permit issued — General Construction
M00649549-I1-GC
01/15/2025
Permit issued — Structural
M00649549-S4-GC
01/14/2025
Filed — Alteration CO
INSTALLATION OF NEW HYDRO-KIT UNITS FOR DOMESTIC WATER HEATING AND INDOOR AHU'S WITH ROOF ACCU'S FOR SPACE HEATING. NEW ROOF TOP UNIT FOR VENTILATION OF COMMON AREAS, NEW CENTRAL KITCHEN AND BATHROOM EXHAUST FANS.
M00649549-P4
Latest 60 of 170 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedApex Building Company01/15/2026
DOB NOWGeneral ConstructionPermit IssuedApex Building Company01/13/2026
DOB NOWSprinklersSigned-offTristate Fire Sprinkler06/04/2025
DOB NOWPlumbingSigned-offIps Plumbing04/21/2025
DOB NOWSolarSigned-offAccord Power04/08/2025
DOB NOWSupported ScaffoldSigned-offReliable Enterprises02/19/2025
DOB NOWConstruction FenceSigned-off4 Brothers Sons Fence02/12/2025
DOB NOWSidewalk ShedSigned-offBK Construction Services01/22/2025
DOB NOWGeneral ConstructionSigned-offApex Building Company01/15/2025
DOB NOWMechanical SystemsSigned-offApex Building Company01/15/2025
DOB NOWGeneral ConstructionPermit IssuedApex Building Company01/15/2025
DOB NOWStructuralPermit IssuedApex Building Company01/15/2025
DOB NOWStructuralPermit IssuedWJ Professional Expeditin12/24/2024
DOB NOWGeneral ConstructionSigned-offWJ Professional Expeditin12/24/2024
DOB NOWGeneral ConstructionPermit IssuedWJ Professional Expeditin12/24/2024
DOB NOWMechanical SystemsSigned-offWJ Professional Expeditin12/17/2024
DOB NOWSprinklersSigned-offTristate Fire Sprinkler06/07/2024
DOB NOWGeneral ConstructionSigned-offApex Building Company06/05/2024
DOB NOWMechanical SystemsSigned-offApex Building Company06/05/2024
DOB NOWGeneral ConstructionPermit IssuedApex Building Company06/05/2024
DOB NOWGeneral ConstructionPermit IssuedApex Building Company06/05/2024
DOB NOWSupported ScaffoldSigned-offReliable Enterprises04/29/2024
DOB NOWPlumbingSigned-offIps Plumbing03/14/2024
DOB NOWConstruction FenceSigned-off4 Brothers Sons Fence01/24/2024
DOB NOWSidewalk ShedSigned-offBK Construction Services01/17/2024
DOB NOWMechanical SystemsSigned-offApex Building Company12/19/2023
DOB NOWGeneral ConstructionPermit IssuedApex Building Company10/30/2023
BISOTISSUEDFresh Meadows Painting02/11/1992
BISPLISSUEDEdward Esbin & Sons12/27/1991
BISOTISSUEDFresh Meadows Painting12/20/1991
1 project · most recent 10/06/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/06/2026Permit IssuedApex Building CompanyAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Lg ARUM121BTE5 129,000 BTU · Vrf Outdoor ×1
ARUM192BTE5 206,000 BTU · Vrf Outdoor ×1
Heating
Lg ARUM168BTES5 180,000 BTU · Vrf Outdoor ×1
Ventilation
Greenheck USF-04-3-B6-00-02-02 250 CFM · Exhaust Fan ×2
G-100HP-5-V6-1-19-X 525 CFM · Kitchen Exhaust ×1
Renewaire HE07-JRTV-S15BB-DGNT-L 300 CFM · Erv ×1
1 project · most recent 10/06/2026
Sprinkler System
FiledStatusContractorScope
10/06/2026Signed-offTristate Fire SprinklerSprinkler System
1 project · most recent 10/06/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
10/06/2026Signed-offIps PlumbingGas, Storm, Water/Sanitary
3 projects · most recent 12/29/2025
General Wiring
FiledStatusContractorScope
12/29/2025CompleteNew Century Electrical ContractingGeneral Wiring
03/19/2025CompleteAccord Power Electric—
01/18/2024CompleteHigh Quality Electric of—
1 project · most recent 10/06/2026
Steel
FiledStatusContractorScope
10/06/2026Permit IssuedApex Building CompanySteel
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
08/07/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/04/2025Certified Sprinkler (SP) - Booster Pump TestCertifiedView ↗
08/04/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/11/2025Pass-Final CND-Occupancy InspectionPassView ↗
08/22/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
08/22/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 74
DateRequirementInspectorRole
09/28/2026Lighting in dwelling unitsSAMI HAJJAR P.Eenergy_progress
09/28/2026Insulation placement and R valuesSAMI HAJJAR P.Eenergy_progress
09/28/2026Fenestration and door U-factor and product ratingsSAMI HAJJAR P.Eenergy_progress
09/28/2026Fenestration air leakageSAMI HAJJAR P.Eenergy_progress
09/28/2026Interior lighting powerSAMI HAJJAR P.Eenergy_progress
09/28/2026Air barrier - visual inspectionSAMI HAJJAR P.Eenergy_progress
09/28/2026Exterior Insulation and Finish Systems (EIFS)SAMI HAJJAR P.Especial
09/28/2026Fire-Resistant Penetrations and JointsSAMI HAJJAR P.Especial
09/28/2026Energy Code Compliance InspectionsSAMI HAJJAR P.Eprogress
09/28/2026Fire-Resistance Rated ConstructionSAMI HAJJAR P.Eprogress
09/28/2026Fenestration areasSAMI HAJJAR P.Eenergy_progress
09/28/2026Lighting controlsSAMI HAJJAR P.Eenergy_progress
09/28/2026Exterior lighting powerSAMI HAJJAR P.Eenergy_progress
02/27/2026Insulation placement and R valuesSAMI HAJJAR P.Eenergy_progress
02/27/2026Exterior Insulation and Finish Systems (EIFS)SAMI HAJJAR P.Especial
02/27/2026Fire-Resistant Penetrations and JointsSAMI HAJJAR P.Especial
02/27/2026Energy Code Compliance InspectionsSAMI HAJJAR P.Eprogress
02/27/2026Fire-Resistance Rated ConstructionSAMI HAJJAR P.Eprogress
02/27/2026Air barrier - visual inspectionSAMI HAJJAR P.Eenergy_progress
02/27/2026Lighting controlsSAMI HAJJAR P.Eenergy_progress
02/27/2026Lighting in dwelling unitsSAMI HAJJAR P.Eenergy_progress
02/27/2026Interior lighting powerSAMI HAJJAR P.Eenergy_progress
02/27/2026Fenestration areasSAMI HAJJAR P.Eenergy_progress
02/27/2026Fenestration and door U-factor and product ratingsSAMI HAJJAR P.Eenergy_progress
02/27/2026Fenestration air leakageSAMI HAJJAR P.Eenergy_progress
Latest 25 of 74.
▾Documents — 126 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
08/28/2026M00649549-P8Request digital key ↗
08/28/2026M00649549-S3Request digital key ↗
08/28/2026M00649549-S2Request digital key ↗
Showing 3 of 15 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION5
10/20/2025110282346Open ↗
10/20/2025110041829Open ↗
11/25/2011110282337Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications54
▸DOB NOWDPL-1: Design Professional Seal & Signature16
10/08/2026M00649549-P9Open ↗
08/28/2026M00988635-I1Open ↗
08/28/2026M00991689-I1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWProgress Inspector Seal & Signature16
10/08/2026M00649549-P9Open ↗
10/08/2026M00649549-P9Open ↗
09/19/2026M00649549-P8Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature16
10/08/2026M00649549-P9Open ↗
10/08/2026M00649549-P9Open ↗
09/19/2026M00649549-P8Open ↗
Showing 3 of 16 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
02/11/2008110282337Open ↗
02/11/2008110282346Open ↗
11/29/2007110041829Open ↗
▸BISPC FULL REPORT3
02/11/2008110282337Open ↗
02/11/2008110282346Open ↗
11/29/2007110041829Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
02/11/2008110282346Open ↗
▸Environmental & Asbestos20
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
10/08/2026M00649549-P9Open ↗
08/13/2026M00649549-S4Open ↗
08/13/2026M00649549-S3Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS INSPECTION REPORT7
02/11/2008110282346Open ↗
02/11/2008110282346Open ↗
02/11/2008110282337Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form5
08/13/2026M00649549-S3Open ↗
08/13/2026M00649549-I1Open ↗
08/13/2026M00649549-S2Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance3
▸DOB NOWPreliminary Commissioning Report Certification2
08/13/2026M00649549-S1Open ↗
08/13/2026M00649549-S2Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026M00649549-I1Open ↗
▸Inspections & Test Reports2
▸BISNOTIF.-PROPOSED STEAM/HOT WATER INSPECTION2
02/11/2008110282346Open ↗
02/11/2008110282346Open ↗
▸Approvals, Objections & Sign-offs21
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter14
10/08/2026M00649549-P9Open ↗
08/13/2026M01182367-I1Open ↗
08/13/2026M00991689-I1Open ↗
Showing 3 of 14 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
06/16/2009120065071Open ↗
02/11/2008110282337Open ↗
02/11/2008110282346Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)1
08/13/2026M00649549-S4Open ↗
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)1
08/13/2026M00649549-S1Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026M01182367-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
06/16/2009120065071Open ↗
▸Filing & Intake Forms1
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
06/16/2009120065071Open ↗
▸Other Documents3
▸BISSEPTIC - SUPPORTING DOCUMENTATION3
02/11/2008110282346Open ↗
02/11/2008110282337Open ↗
02/11/2008110282337Open ↗