ECB09/03/2024At time of my inspection of sidewalk shed at a vacant building. I noticed as per section 3307.6.5 maintenance, repair, use, inspection. Sidewalk shed is missing a parapet panel and loose at point of dislodgeme$625 due
ECB08/27/2012Failure to maintain exterior bldg defect at roof lvl 1/4 of the roof has collapsed near EXP2 & 3 at exp 1 & 2 facade the wood and metal steel girder is corroding breaking rotting and in danger of falling onto tNothing owed — awaiting certificate of correction
ECB08/22/2012Failure to comply w/the comm's order. Note vacate order 142/2012 issued for entire property 8/8/12. At time of inspection corner store stilloperating contrary to vacate order. Remedy: comply w/comm's order &Nothing owed — awaiting certificate of correction
ECB09/02/2009Failure to maintain bldg walls or appurtenances noted bldg missing section of parapet on exp 1 & 2 which exposes interior wood framing and roof joists section of parapet on w 167 st side has loose bricks newNothing owed — awaiting certificate of correction
ECB10/12/2007Failure to maintain exterior of bldg. @ corner of w 167 st & nelson ave bldg facade has been removed & bldg is open to elements (exterior ofbldg needs egress report) remedy: maintain bldg put sidewalk shed upNothing owed — awaiting certificate of correction
ECB10/12/2007Failure to maintain interior holes through out roof & facade has been removed & now open to interior must submit engineers report. Remedy: maintain interior of bldg must submit engineers report to DOB.Nothing owed — awaiting certificate of correction
ECB04/20/2007Failure to maintain exterior bldg. Defect: the corner bldg at 167 st & nelson ave is in disrepair. It appears that the parapet is in danger of collapse. The steel gutter on which the parapet sits atop is rottedNothing owed — awaiting certificate of correction
ECB04/20/2007Failure to maintain interior.defect: there are hole in the stove at m & r deli grocery and hair salon on 167 st. The holes are at the roof area and water has caused damage to the stoves. There is lots of holesNothing owed — awaiting certificate of correction
ECB04/06/2007Failure to maintain.noted:commercial bldg is missing part of facade after metal store awning been removed.exposing ceiling & leaving a hole at front facade.(steel beams corroded).remedy:maintain bldg,make all rNothing owed — awaiting certificate of correction
ECB12/02/2006Failure to maintain bldg haz sheetrock ceiling @rear of hair salon hascome down at sections leaning decomposing wooden structural joists exposed. Mold has formed & other pieces of ceiling peeling off.Nothing owed — awaiting certificate of correction
ECB11/01/2006Failure to maintain exterior bldg wall.noted:rolldown gate & awning collapsed onto sidewalk.roll down gate approx 20FT long & 8FT high awning approx 30FT long approx 5FT high exposing interior of 1-sty commerciNothing owed — awaiting certificate of correction
ECB10/31/2006Failure to maintain adequate housekeeping.metal store awning as well as debris from facade on pedestrian walk way causing unsafe condition to public. Remedy:maintain adequate housekeeping .Nothing owed — awaiting certificate of correction
ECB10/31/2006Failure to maintain -hazardous.mental store awning collapsed & fell onto public walkway along w/ roll down gates. Steel beams exposed at facade reveals corrosion to metal in need of immediate replacement.Nothing owed — awaiting certificate of correction