← Back
Miscellaneous two family
1218 72 STREET
BROOKLYN · Dyker Heights · BIN 3158217
💬 Discuss this project
1930Year Built
2Stories
B9Building Class
R5BZoning
2,052 sfGross Floor Area
2Units
Miscellaneous two family · 2,300 sf lot · 0.89 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 111p · 2 filings · 20 docs
Cellar9p · 1 filing · 16 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MSM ENGINEERING SERVICES, PLLC601/16/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MODERN BUILDING CONSULTANT603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AMC PLBG, HTG & CLNG, INCPlumbing207/08/2026
JZ CONSTRUCTION GROUP INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MSM ENGINEERING SERVICES,8449601/16/2024
Building Lifecycle
All (28)Filed (6)Permit Issued (3)Signed Off (2)Inspection (5)Special Inspection (12)
01/23/2024
Signed off — Alteration
Propose plumbing work for existing residential building as per plan. No change in use, egress, or occupancy.
B00925240-I1
01/18/2024
Signed off — Alteration
Propose interior renovation for existing residential building with partition work and finish work as per plan. No change in use, egress, or occupancy.
B00925164-I1
01/16/2024
Filed — Alteration
Propose plumbing work for existing residential building as per plan. No change in use, egress, or occupancy.
B00925240-P3
12/28/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOHAMED MAHMOUD
12/22/2023
Special inspection requirement — Energy Code Compliance Inspections
MOHAMED MAHMOUD
12/22/2023
Special inspection requirement — Fire-Resistance Rated Construction
MOHAMED MAHMOUD
12/22/2023
Special inspection requirement — Interior lighting power
MOHAMED MAHMOUD
12/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOHAMED MAHMOUD
12/22/2023
Special inspection requirement — Energy Code Compliance Inspections
MOHAMED MAHMOUD
12/21/2023
Filed — Alteration
Propose interior renovation for existing residential building with partition work and finish work as per plan. No change in use, egress, or occupancy.
B00925164-P1
12/18/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/15/2023
Filed — Alteration
Propose plumbing work for existing residential building as per plan. No change in use, egress, or occupancy.
B00925240-P2
12/11/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
11/30/2023
Permit issued — Plumbing
B00925240-I1-PL
11/06/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/30/2023
Filed — Alteration
Propose plumbing work for existing residential building as per plan. No change in use, egress, or occupancy.
B00925240-P1
10/26/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOHAMED MAHMOUD
10/26/2023
Special inspection requirement — Energy Code Compliance Inspections
MOHAMED MAHMOUD
10/26/2023
Special inspection requirement — Fire-Resistance Rated Construction
MOHAMED MAHMOUD
10/26/2023
Special inspection requirement — Interior lighting power
MOHAMED MAHMOUD
10/26/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOHAMED MAHMOUD
10/26/2023
Special inspection requirement — Energy Code Compliance Inspections
MOHAMED MAHMOUD
10/20/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/06/2023
Permit issued — Plumbing
B00925240-I1-PL
08/30/2023
Permit issued — General Construction
B00925164-I1-GC
08/29/2023
Filed — Alteration
Propose plumbing work for existing residential building as per plan. No change in use, egress, or occupancy.
B00925240-I1
08/28/2023
Filed — Alteration
Propose interior renovation for existing residential building with partition work and finish work as per plan. No change in use, egress, or occupancy.
B00925164-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC11/30/2023
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC09/06/2023
DOB NOWGeneral ConstructionSigned-offJZ CONSTRUCTION GROUP INC08/30/2023
BISOTISSUEDHENRYSMITH PROPERTY MGMT07/30/2009
BISPLISSUEDPREMIER FLOW PLBG AND HTG07/30/2009
1 project · most recent 09/08/2023
General Wiring
FiledStatusContractorScope
09/08/2023CompleteR & T ELECTRICAL CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
12/28/2023Pass-Final General Construction Non-Directive 14PassView ↗
12/18/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/11/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/06/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/20/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
12/22/2023Fire-Resistant Penetrations and JointsMOHAMED MAHMOUDspecial
12/22/2023Energy Code Compliance InspectionsMOHAMED MAHMOUDprogress
12/22/2023Fire-Resistance Rated ConstructionMOHAMED MAHMOUDprogress
12/22/2023Interior lighting powerMOHAMED MAHMOUDenergy_progress
12/22/2023Fire-Resistant Penetrations and JointsMOHAMED MAHMOUDspecial
12/22/2023Energy Code Compliance InspectionsMOHAMED MAHMOUDprogress
10/26/2023Fire-Resistant Penetrations and JointsMOHAMED MAHMOUDspecial
10/26/2023Energy Code Compliance InspectionsMOHAMED MAHMOUDprogress
10/26/2023Fire-Resistance Rated ConstructionMOHAMED MAHMOUDprogress
10/26/2023Interior lighting powerMOHAMED MAHMOUDenergy_progress
10/26/2023Fire-Resistant Penetrations and JointsMOHAMED MAHMOUDspecial
10/26/2023Energy Code Compliance InspectionsMOHAMED MAHMOUDprogress
▾Documents — 43 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/26/2026B00925164-P1Request digital key ↗
08/26/2026B00925164-I1Request digital key ↗
08/26/2026B00925240-P2Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
07/30/2009320051867Open ↗
07/30/2009320051867Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
07/15/2009320051867Open ↗
▸Seals & Professional Certifications18
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/26/2026B00925164-I1Open ↗
08/26/2026B00925240-P2Open ↗
08/26/2026B00925240-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/02/2026B00925240-P1Open ↗
08/26/2026B00925164-P1Open ↗
08/26/2026B00925164-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/02/2026B00925240-P1Open ↗
08/26/2026B00925164-P1Open ↗
08/26/2026B00925164-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
01/28/2010320051867Open ↗
07/15/2009320051867Open ↗
▸Trade Schedules & Equipment2
▸BISSELF-CERT PLUMBING NOTICE1
10/29/2009320051867Open ↗
▸BISSCHEDULE B - PLUMBING1
07/15/2009320051867Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/26/2026B00925164-I1Open ↗
08/26/2026B00925240-P1Open ↗
08/26/2026B00925240-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
07/15/2009320051867Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
02/23/2010320051867Open ↗
01/28/2010320051867Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
07/15/2009320051867Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
01/28/2010320051867Open ↗
07/15/2009320051867Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
07/15/2009320051867Open ↗
▸Other Documents1
▸BISRESTRICTION: DEED1
07/30/2009320051867Open ↗