← Back
Church, synagogue, chapel
1218 GLENWOOD ROAD
BROOKLYN · Flatbush (West)-Ditmas Park-Parkville · BIN 3178925
💬 Discuss this project
1931Year Built
1Stories
M1Building Class
R2Zoning
4,876 sfGross Floor Area
0Units
0 Open ViolationsFDNY Report ↗
Church, synagogue, chapel · 10,000 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalEquipment
Roof8p · 3 filings · 20 docs
Floor 27p · 3 filings · 20 docs
Floor 18p · 4 filings · 20 docs
Site & exterior4p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CHURCH OF JESUS CHRIST OF LATTER303/21/2026
CHURCH OF LATTER DAY SAINTS103/22/2026
CHURCH OF JESUS CHRIST103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WILLIAM VITACCO ASSOCIATES803/21/2026
EUROCELT EXPEDITING, INC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CONSOLIDATED SCAFFOLDINGGeneral Contractor907/08/2026
L & M CONSTRUCTION/DRY WAGeneral Contractor307/08/2026
HENRY KHODOSHElectrical203/21/2026
DECLAN DELAHUNTYElectrical103/21/2026
SHUIR ELEC'L CONTR'S CORPElectrical103/22/2026
VAN VASSELLElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CELIN MUNOZ CONSULTING EN1064307/06/2021
Building Lifecycle
All (56)Filed (6)Permit Issued (8)Signed Off (5)Violation (10)Objection (12)Special Inspection (15)
01/23/2023
Signed off — Alteration
Structural work as shown on plans filed herewith in conjunction with general construction (#B00518417-I1) and demolition means and methods (#B00518460-I1) filed separately. No change in use. egress or occupancy.
B00518453-I1
01/11/2023
Signed off — Alteration
B00518460-I1
11/21/2022
Signed off — Alteration
REPAIR EXISTING BELL-TOWER MASONRY, ROOF, INTERIOR PARTITIONS, REPAIR EXISTING STRUCTURAL STEEL, REPLACE/REPAIR EXISTING WINDOWS AND WOOD FIXTURE IN EXISTING OPENING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00518417-I1
09/15/2022
Signed off — Alteration
B00336121-I1
09/15/2022
Signed off — Alteration
B00336118-I1
03/23/2022
Permit issued — Sidewalk Shed
B00336118-I1-SH
09/21/2021
Permit issued — Structural
B00518453-I1-ST
09/07/2021
Filed — Alteration
Structural work as shown on plans filed herewith in conjunction with general construction (#B00518417-I1) and demolition means and methods (#B00518460-I1) filed separately. No change in use. egress or occupancy.
B00518453-P1
07/30/2021
Permit issued — General Construction
B00518417-I1-GC
07/26/2021
Special inspection requirement — Structural Steel - High Strength Bolting
07/26/2021
Special inspection requirement — Structural Steel - Welding
07/19/2021
Special inspection requirement — Final
07/19/2021
Special inspection requirement — Structural Steel - Details
07/19/2021
Special inspection requirement — Masonry
07/19/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/06/2021
Filed — Alteration
Structural work as shown on plans filed herewith in conjunction with general construction (#B00518417-I1) and demolition means and methods (#B00518460-I1) filed separately. No change in use. egress or occupancy.
B00518453-I1
07/06/2021
Permit issued — Structural
B00518460-I1-ST
06/08/2021
Objection raised — Scope
06/08/2021
Objection resolved — Addressed
06/08/2021
Objection raised — Structural
06/08/2021
Objection resolved — Addressed
06/08/2021
Objection raised — Energy
06/08/2021
Objection resolved — Addressed
06/08/2021
Objection raised — Scope
06/08/2021
Objection resolved — Addressed
06/08/2021
Objection raised — Structural
06/08/2021
Objection resolved — Addressed
06/08/2021
Objection raised — Scope
06/08/2021
Objection resolved — Addressed
06/04/2021
Filed — Alteration
B00518460-I1
06/04/2021
Filed — Alteration
REPAIR EXISTING BELL-TOWER MASONRY, ROOF, INTERIOR PARTITIONS, REPAIR EXISTING STRUCTURAL STEEL, REPLACE/REPAIR EXISTING WINDOWS AND WOOD FIXTURE IN EXISTING OPENING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00518417-I1
05/26/2021
Special inspection requirement — Masonry
Celin Munoz
05/26/2021
Special inspection requirement — Masonry
Celin Munoz
05/26/2021
Special inspection requirement — Structural Steel - High Strength Bolting
Celin Munoz
05/26/2021
Special inspection requirement — Structural Steel - Welding
Celin Munoz
05/26/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Celin Munoz
05/26/2021
Special inspection requirement — Structural Steel - Details
Celin Munoz
05/26/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Celin Munoz
05/07/2021
Special inspection requirement — Final
EMILY CHANG-ZIDAROV
05/07/2021
Special inspection requirement — Final
Celin Munoz
03/24/2021
Permit issued — Sidewalk Shed
B00336118-I1-SH
03/22/2021
Permit issued — Supported Scaffold
B00336121-I1-SF
03/24/2020
Permit issued — Supported Scaffold
B00336121-I1-SF
03/23/2020
Filed — Alteration
B00336121-I1
03/23/2020
Permit issued — Sidewalk Shed
B00336118-I1-SH
03/21/2020
Filed — Alteration
B00336118-I1
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING03/23/2022
DOB NOWStructuralSigned-offL & M CONSTRUCTION/DRY WA09/21/2021
DOB NOWGeneral ConstructionSigned-offL & M CONSTRUCTION/DRY WA07/30/2021
DOB NOWStructuralSigned-offL & M CONSTRUCTION/DRY WA07/06/2021
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING03/24/2021
DOB NOWSupported ScaffoldSigned-offCONSOLIDATED SCAFFOLDING03/22/2021
DOB NOWSupported ScaffoldSigned-offCONSOLIDATED SCAFFOLDING03/24/2020
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING03/23/2020
BISOTISSUEDJ T REILLY CONSTRUCTION CO INC08/04/1993
2 projects · most recent 10/06/2021
FiledStatusContractorScope
10/06/2021CompleteSHUIR ELEC'L CONTR'S CORP—
03/25/2020CompleteV. VASS ELECTRIC CORP—
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
07/26/2021Structural Steel - High Strength Bolting—special
07/26/2021Structural Steel - Welding—special
07/19/2021Final—progress
07/19/2021Structural Steel - Details—special
07/19/2021Masonry—special
07/19/2021Structural Stability – Alterations of existing buildings—special
05/26/2021MasonryCelin Munozspecial
05/26/2021MasonryCelin Munozspecial
05/26/2021Structural Steel - High Strength BoltingCelin Munozspecial
05/26/2021Structural Steel - WeldingCelin Munozspecial
05/26/2021Structural Stability – Alterations of existing buildingsCelin Munozspecial
05/26/2021Structural Steel - DetailsCelin Munozspecial
05/26/2021Structural Stability – Alterations of existing buildingsCelin Munozspecial
05/07/2021FinalEMILY CHANG-ZIDAROVprogress
05/07/2021FinalCelin Munozprogress
▾Documents — 62 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch4
09/01/2026B00518460-I1Request digital key ↗
09/01/2026B00518417-I1Request digital key ↗
09/01/2026B00518453-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/02/2026B00336118-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/02/2026B00336121-I1Request digital key ↗
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION5
06/03/2025321940646Open ↗
06/03/2025340747909Open ↗
07/21/2020340747909Open ↗
Showing 3 of 5 on file for this type
▸BISPARTIAL DEMO PLAN & DS1 (FOR AL/EW-OT PERMITS)2
07/28/2020321940646Open ↗
07/28/2020340747909Open ↗
▸BISPARTIAL DEMO: 10-DAY NOTICE (FOR AL/EW-OT PERMITS)1
07/28/2020340747909Open ↗
▸Seals & Professional Certifications20
▸DOB NOWSpecial Inspector Seal & Signature7
08/26/2026B00518460-I1Open ↗
08/26/2026B00518460-I1Open ↗
08/26/2026B00518460-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
09/01/2026B00518460-I1Open ↗
09/01/2026B00518417-I1Open ↗
09/01/2026B00518453-P1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
04/08/2019321940646Open ↗
04/08/2019321940646Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026B00518460-I1Open ↗
08/24/2026B00518417-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/21/2020340747909Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/21/2020340747909Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
07/21/2020340747909Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form3
09/01/2026B00518460-I1Open ↗
09/01/2026B00518417-I1Open ↗
09/01/2026B00518453-I1Open ↗
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
07/21/2020340747909Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
08/05/2020321940646Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/21/2020340747909Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
04/08/2019321940646Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
07/21/2020340747909Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY3
08/05/2020321940646Open ↗
07/28/2020340747909Open ↗
07/21/2020340747909Open ↗
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)1
08/06/2020321940646Open ↗
▸Approvals, Objections & Sign-offs5
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter5
09/01/2026B00518460-I1Open ↗
09/01/2026B00518417-I1Open ↗
09/01/2026B00518453-I1Open ↗
Showing 3 of 5 on file for this type
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT3
07/21/2020340747909Open ↗
04/08/2019321940646Open ↗
04/08/2019321940646Open ↗
▸BISPROJECT-SPECIFIC GL INSURANCE1
07/28/2020340747909Open ↗
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET2
04/08/2019321940646Open ↗
04/08/2019321940646Open ↗
▸BISADDITIONAL INFORMATION2
08/06/2020340747909Open ↗
08/06/2020340747909Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
07/21/2020340747909Open ↗
▸Other Documents2
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
07/21/2020340747909Open ↗
▸BISFEE EXEMPTION DOCUMENTATION1
07/21/2020340747909Open ↗