← Back
One story - permanent living quarter
122-21 LONG STREET
QUEENS · BIN 4265900
💬 Discuss this project
1960Year Built
1Stories
A2Building Class
R3AZoning
960 sfGross Floor Area
1Units
One story - permanent living quarter · 4,000 sf lot · 0.24 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralPlumbingCivil
Permit Issued — active, not yet Signed-off
Floor 2Under Construction6p · 1 filing · 20 docs
Floor 1Under Construction6p · 1 filing · 20 docs
CellarUnder Construction10p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
UNITED DEVELOPERS1207/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/04/2025$620K—Private party → MRT BUYERS LLC$646/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
D&E BUILD EVERGREEN INC.305/01/2026
PETER CHO ARCHITECTS, PLLC108/18/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METRO DESIGN CONSULTANTS INC603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRECISION HOME DEV INCGeneral Contractor307/08/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
D&E BUILD EVERGREEN I9342305/01/2026
IP CONCRETE TESTING AND I6252108/19/2025
Building Lifecycle
All (58)Filed (4)Permit Issued (4)Inspection (12)Objection (8)Special Inspection (30)
07/01/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/22/2026
Special inspection requirement — Air barrier — testing
Danny Chen
06/22/2026
Special inspection requirement — Air barrier - visual inspection
Danny Chen
06/22/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Danny Chen
06/22/2026
Special inspection requirement — Electric vehicle service equipment requirements
Danny Chen
06/22/2026
Special inspection requirement — Insulation placement and R values
Danny Chen
06/22/2026
Special inspection requirement — HVAC-R and service water heating system controls
Danny Chen
06/22/2026
Special inspection requirement — Maintenance information
Danny Chen
06/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
Danny Chen
06/22/2026
Special inspection requirement — Ventilation and air distribution system
Danny Chen
06/22/2026
Special inspection requirement — Structural Steel - High Strength Bolting
Danny Chen
06/22/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
INDARDEO PARBHUNATH
06/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Danny Chen
06/22/2026
Special inspection requirement — Masonry
Danny Chen
06/22/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Danny Chen
06/22/2026
Special inspection requirement — Subgrade Inspections
Danny Chen
06/22/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Danny Chen
06/22/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Danny Chen
06/22/2026
Special inspection requirement — Concrete - Cast-In-Place
Danny Chen
06/22/2026
Special inspection requirement — Mechanical Systems
Danny Chen
06/22/2026
Special inspection requirement — Heating Systems
Danny Chen
06/22/2026
Special inspection requirement — Structural Steel - Details
Danny Chen
06/22/2026
Special inspection requirement — Footing and Foundation
Danny Chen
06/22/2026
Special inspection requirement — Energy Code Compliance Inspections
Danny Chen
06/22/2026
Special inspection requirement — Fire-Resistance Rated Construction
Danny Chen
06/22/2026
Special inspection requirement — Structural Wood Frame
Danny Chen
06/22/2026
Special inspection requirement — Final
PETER CHO
06/22/2026
Special inspection requirement — Metering
Danny Chen
06/22/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Danny Chen
06/22/2026
Special inspection requirement — Fenestration areas
Danny Chen
06/22/2026
Special inspection requirement — Fenestration air leakage
Danny Chen
06/09/2026
Permit issued — Construction Fence
Q01273445-S1-FN
05/01/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING ONE STORY ONE-FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTICAL & HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01273445-P1
04/01/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/24/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/07/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/17/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/17/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
12/17/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/14/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/10/2025
Permit issued — Plumbing
Q01273445-S2-PL
12/10/2025
Permit issued — Earth Work
Q01273445-I1-GC-CX
11/07/2025
Permit issued — Construction Fence
Q01273445-S1-FN
10/08/2025
Objection resolved — Addressed
10/08/2025
Objection resolved — Addressed
09/18/2025
Objection resolved — Addressed
09/16/2025
Objection resolved — Addressed
09/11/2025
Objection raised — Cost
09/11/2025
Objection raised — Admin
09/11/2025
Objection raised — Structural
09/04/2025
Objection raised — Scope
08/19/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING ONE STORY ONE-FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTICAL & HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01273445-S2
08/18/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING ONE STORY ONE-FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTICAL & HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01273445-I1
08/18/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING ONE STORY ONE-FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTICAL & HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01273445-S1
12/26/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/12/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/05/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedPRECISION HOME DEV INC06/09/2026
DOB NOWPlumbingPermit IssuedINFINITI ESC PLUMBING COR12/10/2025
DOB NOWEarth WorkPermit IssuedPRECISION HOME DEV INC12/10/2025
DOB NOWConstruction FencePermit IssuedPRECISION HOME DEV INC11/07/2025
1 project · most recent 05/01/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/01/2026Permit IssuedPRECISION HOME DEV INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Cooper & Hunter CH-N48LCU-230VO 48,000 BTU · Condensing Unit ×1
CH-N60LCU-230VO 60,000 BTU · Condensing Unit ×1
Samsung AC048FCUDCG 48,000 BTU · Vrf Indoor ×1
AC060FCUDCG 60,000 BTU · Vrf Indoor ×1
Heating
Cooper & Hunter CH-48AHU 48,000 BTU · Fan Coil Indoor ×1
CH-60AHU 60,000 BTU · Fan Coil Indoor ×1
Daikin AMST48CU1300AA 48,000 BTU · Ahu ×1
AMST60DU1300AA 60,000 BTU · Ahu ×1
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×5
Delta Breeze SMT150 150 CFM · Exhaust Fan ×2
1 project · most recent 05/01/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/01/2026Permit IssuedINFINITI ESC PLUMBING CORGas, Storm, Water/Sanitary
1 project · most recent 12/11/2025
General Wiring
FiledStatusContractorScope
12/11/2025CompleteSKY ELECTRIC LLCGeneral Wiring
1 project · most recent 05/01/2026
Steel Wood
FiledStatusContractorScope
05/01/2026Permit IssuedPRECISION HOME DEV INCSteel, Wood
1 project · most recent 05/01/2026
Fence
FiledStatusContractorScope
05/01/2026Permit IssuedPRECISION HOME DEV INCFence
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
07/01/2026Pass-Final CND-Occupancy InspectionPassView ↗
04/01/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/24/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/07/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/19/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/17/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
12/17/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
12/17/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/14/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/26/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/12/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/05/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 41
DateRequirementInspectorRole
06/22/2026Air barrier — testing Danny Chenenergy_progress
06/22/2026Air barrier - visual inspectionDanny Chenenergy_progress
06/22/2026HVAC-R and service water piping design and insulationDanny Chenenergy_progress
06/22/2026Electric vehicle service equipment requirementsDanny Chenenergy_progress
06/22/2026Insulation placement and R valuesDanny Chenenergy_progress
06/22/2026HVAC-R and service water heating system controlsDanny Chenenergy_progress
06/22/2026Maintenance informationDanny Chenenergy_progress
06/22/2026HVAC-R and service water heating equipmentDanny Chenenergy_progress
06/22/2026Ventilation and air distribution systemDanny Chenenergy_progress
06/22/2026Structural Steel - High Strength BoltingDanny Chenspecial
06/22/2026Subsurface Investigations (Borings/Test Pits)INDARDEO PARBHUNATHspecial
06/22/2026Fire-Resistant Penetrations and JointsDanny Chenspecial
06/22/2026MasonryDanny Chenspecial
06/22/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationDanny Chenspecial
06/22/2026Subgrade InspectionsDanny Chenspecial
06/22/2026Excavations - Sheeting, Shoring, and BracingDanny Chenspecial
06/22/2026Structural Stability – Alterations of existing buildingsDanny Chenspecial
06/22/2026Concrete - Cast-In-PlaceDanny Chenspecial
06/22/2026Mechanical SystemsDanny Chenspecial
06/22/2026Heating SystemsDanny Chenspecial
06/22/2026Structural Steel - DetailsDanny Chenspecial
06/22/2026Footing and FoundationDanny Chenprogress
06/22/2026Energy Code Compliance InspectionsDanny Chenprogress
06/22/2026Fire-Resistance Rated ConstructionDanny Chenprogress
06/22/2026Structural Wood FrameDanny Chenprogress
Latest 25 of 41.
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/17/2026Q01273445-S1Request digital key ↗
08/17/2026Q01273445-I1Request digital key ↗
08/17/2026Q01273445-S2Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/17/2026Q01273445-P1Open ↗
08/13/2026Q01273445-I1Open ↗
▸Seals & Professional Certifications13
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026Q01273445-I1Open ↗
09/01/2026Q01273445-I1Open ↗
09/01/2026Q01273445-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/17/2026Q01273445-S2Open ↗
08/17/2026Q01273445-S1Open ↗
08/17/2026Q01273445-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026Q01273445-I1Open ↗
09/01/2026Q01273445-I1Open ↗
08/23/2026Q01273445-S2Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/17/2026Q01273445-I1Open ↗
08/17/2026Q01273445-P1Open ↗
08/17/2026Q01273445-S2Open ↗
▸Inspections & Test Reports3
▸DOB NOWSOIL REPORT2
08/17/2026Q01273445-P1Open ↗
08/13/2026Q01273445-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01273445-I1Open ↗
▸Other Documents8
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/17/2026Q01273445-I1Open ↗
08/17/2026Q01273445-P1Open ↗
08/13/2026Q01273445-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/17/2026Q01273445-P1Open ↗
08/13/2026Q01273445-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/17/2026Q01273445-I1Open ↗
08/17/2026Q01273445-P1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q01273445-I1Open ↗