← Back
Two family converted from one family
122-35 133 AVENUE
QUEENS · BIN 4254136
💬 Discuss this project
1925Year Built
2.5Stories
B3Building Class
R3-2Zoning
1,488 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · Owner of record: 122-35 B & L LLC · 3,000 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 25p · 1 filing · 18 docs
Floor 15p · 1 filing · 18 docs
Cellar5p · 1 filing · 18 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/30/2022$680K—— → —$457/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEE ENGINEERING, P.C.207/11/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LEE ENGINEERING P C403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
C.R.U. MECHAN & HEAT INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LEE ENGINEERING, P.C.2157207/11/2023
Building Lifecycle
All (27)Filed (2)Permit Issued (1)Violation (7)Inspection (5)Special Inspection (12)
01/22/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/04/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/19/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/13/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
YEON LEE
07/13/2023
Special inspection requirement — Energy Code Compliance Inspections
YEON LEE
07/13/2023
Special inspection requirement — HVAC-R and service water heating system controls
YEON LEE
07/13/2023
Special inspection requirement — Maintenance information
YEON LEE
07/13/2023
Special inspection requirement — HVAC-R and service water heating equipment
YEON LEE
07/13/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
YEON LEE
07/11/2023
Filed — Alteration
SEPARATE A GAS SYSTEM INTO 2 INDIVIDUAL GAS SYSTEMS FOR EXISTING 2 FAMILY HOUSE BY SETTING A NEW HEADER SERVICE WITH (1)UPGRADED GAS METER AND GAS METER INSTALL AND REPLACED GAS EQUIPMENT. GAS PIPING WILL BE REPLACED IN CELLAR ONLY.
Q00885274-P1
07/11/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
YEON LEE
07/11/2023
Special inspection requirement — Energy Code Compliance Inspections
YEON LEE
07/11/2023
Special inspection requirement — Maintenance information
YEON LEE
07/11/2023
Special inspection requirement — HVAC-R and service water heating system controls
YEON LEE
07/11/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
YEON LEE
07/11/2023
Special inspection requirement — HVAC-R and service water heating equipment
YEON LEE
07/07/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/07/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/26/2023
Permit issued — Plumbing
Q00885274-I1-PL
06/15/2023
Filed — Alteration
SEPARATE A GAS SYSTEM INTO 2 INDIVIDUAL GAS SYSTEMS FOR EXISTING 2 FAMILY HOUSE BY SETTING A NEW HEADER SERVICE WITH (1)UPGRADED GAS METER AND GAS METER INSTALL AND REPLACED GAS EQUIPMENT. GAS PIPING WILL BE REPLACED IN CELLAR ONLY.
Q00885274-I1
08/14/2000
Violation issued (ECB, closed)
Quality of Life
08/14/2000
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
12/06/1999
Violation issued (ECB, closed)
Quality of Life
12/06/1999
Violation issued (ECB, closed)
Construction
11/22/1999
Violation issued (ECB, closed)
Quality of Life
05/27/1999
Violation issued (ECB, closed)
Quality of Life
05/27/1999
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedC.R.U. MECHAN & HEAT INC06/26/2023
1 project · most recent 07/11/2023
Gas
FiledStatusContractorScope
07/11/2023Permit IssuedC.R.U. MECHAN & HEAT INCGas
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
01/22/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/04/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/19/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/07/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/07/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
07/13/2023Fire-Resistant Penetrations and JointsYEON LEEspecial
07/13/2023Energy Code Compliance InspectionsYEON LEEprogress
07/13/2023HVAC-R and service water heating system controlsYEON LEEenergy_progress
07/13/2023Maintenance informationYEON LEEenergy_progress
07/13/2023HVAC-R and service water heating equipmentYEON LEEenergy_progress
07/13/2023HVAC-R and service water piping design and insulationYEON LEEenergy_progress
07/11/2023Fire-Resistant Penetrations and JointsYEON LEEspecial
07/11/2023Energy Code Compliance InspectionsYEON LEEprogress
07/11/2023Maintenance informationYEON LEEenergy_progress
07/11/2023HVAC-R and service water heating system controlsYEON LEEenergy_progress
07/11/2023HVAC-R and service water piping design and insulationYEON LEEenergy_progress
07/11/2023HVAC-R and service water heating equipmentYEON LEEenergy_progress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026Q00885274-P1Request digital key ↗
08/24/2026Q00885274-I1Request digital key ↗
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature10
09/01/2026Q00885274-I1Open ↗
09/01/2026Q00885274-I1Open ↗
09/01/2026Q00885274-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026Q00885274-P1Open ↗
08/24/2026Q00885274-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q00885274-I1Open ↗
08/26/2026Q00885274-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/24/2026Q00885274-P1Open ↗
08/24/2026Q00885274-I1Open ↗