ECB08/04/2026FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT INSPECTION, OBSERVED STEP CRACKS ABOVE THE 5TH-STORY WINDOW LINTEL AT EXPOSURE 1 AND MULTIPLE CRACKS AT EXPOSURE 2. ALSO OBSERVED A DETERIORATED, PEEL$2K due
ECB04/06/2026WORK WITHOUT A PERMIT. AT TIME OF CELLAR OBSERVED ASSOCIATED ELECTRICAL WORK FOR LIGHTING, OUTLETS AND RECEPTACLES THROUGHOUT MULTIPLE ROOMS. NO PERMITS ON FILE., OBTAIN PERMIT$6K due
ECB04/06/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED SPRINKLER MAIN CONTROL VALVE ROOM CELLAR STEEL BEAMS CRACKED, RUSTED, DETERIOATING AND IN SEVERE DISREPAIR CREATING HAZARDOU$6K due
ECB04/06/2026WORK WITHOUT A PERMIT. AT TIME OF INSPECTION AT CELLAR OBSERVED ASSOCIATED PLUMBING WORK FOR 2-PIECE BATHROOM WITH STAND-UP SHOWER AND SINK. NO PERMIT ON FILE., OBTAIN PERMIT$6K due
ECB04/06/2026OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDINGS DEPARTMENT RECORDS. AT TIME OF INSPECTION OBSERVED ROOM APPROX. 15'WX35'L ROOM FOR WORSHIP, SRO/SLEEPING QUARTERS, FULL PARTITIONS$6K due
DOB04/06/2026FAILURE TO MAINTAIN BLDG IN SAFE CONDITION.122 DUANE ST VAULT@THE CENTER HAD CRCKS@UNDERSIDE OF VAULT CEILNG&WALLS.VARIOUS STEEL BEAMS EXPOSD&CORRODED W/SPALLD CONCRTE COVR.CORRODED STEEL BEAM.1.OWNR TO RTAIN NYSPE TO EVAL ENT STRCTRE&FILE RPAIR DWGS W/DOB,2.BLDG TO BE PERM RPAIRD UNDR PRMT STRTNG BY 5/18/26
DOB04/06/2026EMERGENCY WORK ORDER.122 DUANE ST VAULT@THE CELLAR HAD CRACKS@UNDERSDE OF VAULT CEILNG&WALLS/VARIOUS STEEL BEAMS EXPSD&CORRODED W/SPALLD CNCRTE COVER.STEEL BEAM NEAR THE CELLAR ENTRANCE DOOR.OWNR TO RTAIN NYSPE&GC REG W/DOB TO IMMED 1.NYSPE TO SUBMIT MEANS&METHDS FOR TEMP SHORNG/STBLZTN AS REQ'D TO FEU BY 4/7/26
ECB04/19/2018WORK W/OUT A PERMIT.@TIME OF INSP OBSERVED ALONG CHURCH & DUANE STREETS THE ILLEGAL INSTALLATION OF MULTIPLE ACESSORY TO THE FOLLOWING BUSINESSES:WORLD OF DIAMONDS,DOWNTOWN SHOES,BURRITO MARIACHI SUSHI METRO PC$3K due
DOB11/14/2016VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
HPD09/24/2014§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
DOB05/30/2014VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
HPD05/10/2011§ 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING , 100 WATTS REQUIRED.
HPD04/26/2006§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST