← Back
Zoned residential, not Manhattan
1220 SPOFFORD AVENUE
BRONX · Hunts Point · BIN 2131153
💬 Discuss this project
0Year Built
—Stories
V0Building Class
R6Zoning
0 sfGross Floor Area
0Units
2 Open Violations 0 unresolved · 2 paperwork only ▸
Zoned residential, not Manhattan · Owner of record: 1220 SPOFFORD HOUSING DEVELOPMENT FUND C ORPORATION · 12,500 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction34p · 2 filings · 20 docs
Floor 6Under Construction38p · 2 filings · 20 docs
Floor 5Under Construction118p · 2 filings · 20 docs
Floor 4Under Construction115p · 2 filings · 20 docs
Floor 3Under Construction114p · 2 filings · 20 docs
Floor 2Under Construction115p · 2 filings · 20 docs
Floor 1Under Construction123p · 3 filings · 20 docs
CellarUnder Construction124p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TITAN SERVICES USA209/13/2026
DOE FUND2908/22/2026
NUNZIO DEL FRECCO REALTY103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WILLIAM VITACCO ASSOCIATES803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CRESCENT BUILDERS, INCGeneral Contractor907/08/2026
TITAN SERVICES USA INCGeneral Contractor108/26/2026
WITH PRIDE AIR CONDITIONINGGeneral Contractor108/22/2026
FLINT MECHANICAL CORPPlumbing107/10/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GEODESIGN, INC., P.C.627201/13/2022
AMERICAN CONSTRUCTION TES9731511/18/2021
Building Lifecycle
All (99)Filed (10)Permit Issued (12)Violation (1)Objection (46)Special Inspection (30)
08/21/2026
Permit issued — Mechanical Systems
X00552335-S4-MS
08/03/2026
Filed — New Building
Structural work for New Building.
X00552335-S7
08/03/2026
Permit issued — Sidewalk Shed
X00552335-S7-SH
07/09/2026
Permit issued — Plumbing
X00552335-S5-PL
07/02/2026
Permit issued — Structural
X00552335-S3-ST
07/02/2026
Permit issued — Support of Excavation
X00552335-S2-SE
07/01/2026
Permit issued — Foundation
X00552335-S6-FO
07/01/2026
Permit issued — General Construction
X00552335-I1-GC
06/26/2026
Permit issued — Foundation
X00552335-S6-FO
06/26/2026
Permit issued — Structural
X00552335-S3-ST
06/17/2026
Permit issued — General Construction
X00552335-I1-GC
06/17/2026
Permit issued — Support of Excavation
X00552335-S2-SE
04/30/2026
Permit issued — Construction Fence
X01391831-I1-FN
04/27/2026
Filed — Alteration
X01391831-I1
03/11/2026
Objection resolved — Addressed
03/06/2026
Objection resolved — Addressed
02/20/2026
Objection resolved — Addressed
02/20/2026
Objection resolved — Addressed
02/20/2026
Objection resolved — Addressed
02/11/2026
Special inspection requirement — Protection of exposed foundation insulation
EDWIN HOPKINS
02/11/2026
Special inspection requirement — Fenestration areas
EDWIN HOPKINS
02/11/2026
Special inspection requirement — Insulation placement and R values
EDWIN HOPKINS
02/11/2026
Special inspection requirement — Vestibules
EDWIN HOPKINS
02/11/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
EDWIN HOPKINS
02/11/2026
Special inspection requirement — Fenestration air leakage
EDWIN HOPKINS
02/11/2026
Special inspection requirement — Air barrier - visual inspection
EDWIN HOPKINS
02/11/2026
Special inspection requirement — Energy Code Compliance Inspections
EDWIN HOPKINS
02/11/2026
Special inspection requirement — Fire-Resistance Rated Construction
EDWIN HOPKINS
02/11/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
EDWIN HOPKINS
02/11/2026
Special inspection requirement — Sprayed fire-resistant materials
EDWIN HOPKINS
02/11/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
EDWIN HOPKINS
01/28/2026
Objection resolved — Addressed
01/22/2026
Objection resolved — Addressed
01/21/2026
Objection raised — C/O of existing property requi
01/09/2026
Filed — New Building
Structural work for New Building.
X00552335-P1
01/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/07/2026
Special inspection requirement — Sprayed fire-resistant materials
01/07/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
01/07/2026
Special inspection requirement — Energy Code Compliance Inspections
01/07/2026
Special inspection requirement — Fire-Resistance Rated Construction
01/07/2026
Special inspection requirement — Fenestration areas
01/07/2026
Special inspection requirement — Air barrier - visual inspection
01/07/2026
Special inspection requirement — Fenestration air leakage
01/07/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
01/07/2026
Special inspection requirement — Insulation placement and R values
01/07/2026
Special inspection requirement — Protection of exposed foundation insulation
01/07/2026
Special inspection requirement — Vestibules
06/16/2023
Objection resolved — Addressed
06/16/2023
Objection resolved — Addressed
06/16/2023
Objection resolved — Addressed
06/16/2023
Objection resolved — Addressed
06/13/2023
Special inspection requirement — Interior lighting power
EDWIN HOPKINS
06/13/2023
Special inspection requirement — Lighting in dwelling units
EDWIN HOPKINS
06/13/2023
Special inspection requirement — Lighting controls
EDWIN HOPKINS
06/13/2023
Special inspection requirement — Exterior lighting power
EDWIN HOPKINS
06/13/2023
Special inspection requirement — Shutoff dampers
EDWIN HOPKINS
06/13/2023
Special inspection requirement — Electrical motors and elevators
EDWIN HOPKINS
09/21/2022
Objection raised — Structural
09/21/2022
Objection resolved — Addressed
09/21/2022
Objection raised — Mechanical
Latest 60 of 99 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedWITH PRIDE AIR CONDITIONING08/21/2026
DOB NOWSidewalk ShedPermit IssuedTITAN SERVICES USA INC08/03/2026
DOB NOWPlumbingPermit IssuedFLINT MECHANICAL CORP07/09/2026
DOB NOWStructuralPermit IssuedCRESCENT BUILDERS, INC07/02/2026
DOB NOWSupport of ExcavationPermit IssuedCRESCENT BUILDERS, INC07/02/2026
DOB NOWFoundationPermit IssuedCRESCENT BUILDERS, INC07/01/2026
DOB NOWGeneral ConstructionPermit IssuedCRESCENT BUILDERS, INC07/01/2026
DOB NOWFoundationPermit IssuedCRESCENT BUILDERS, INC06/26/2026
DOB NOWStructuralPermit IssuedCRESCENT BUILDERS, INC06/26/2026
DOB NOWGeneral ConstructionPermit IssuedCRESCENT BUILDERS, INC06/17/2026
DOB NOWSupport of ExcavationPermit IssuedCRESCENT BUILDERS, INC06/17/2026
DOB NOWConstruction FencePermit IssuedCRESCENT BUILDERS, INC04/30/2026
1 project · most recent 08/03/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/03/2026Permit IssuedWITH PRIDE AIR CONDITIONIAir Conditioning Systems
Cooling
Mitsubishi Electric PUHY-P96TNU-A 96,000 BTU · Vrf Outdoor ×4
PUHY-P120TNU-A 120,000 BTU · Vrf Outdoor ×2
PUY-A24NHA7 24,000 BTU · Split System ×2
PUHY-P144TNU-A 144,000 BTU · Vrf Outdoor ×1
PURY-P168TNU-A 168,000 BTU · Vrf Outdoor ×1
1 project · most recent 02/11/2022
FiledStatusContractorScope
02/11/2022———
1 project · most recent 08/03/2026
Storm Water/Sanitary
FiledStatusContractorScope
08/03/2026Permit IssuedBLETSAS P&H CORPStorm, Water/Sanitary
3 projects · most recent 07/29/2026
General Wiring
FiledStatusContractorScope
07/29/2026Permit IssuedHIGH QUALITY ELEC.OF NYC—
06/30/2026Permit IssuedBASS ELECTRICAL CORP.—
06/25/2026Permit IssuedBASS ELECTRICAL CORP.General Wiring
1 project · most recent 08/03/2026
Steel Concrete Masonry
FiledStatusContractorScope
08/03/2026Permit IssuedWITH PRIDE AIR CONDITIONISteel, Concrete, Masonry
▾Special Inspection Requirements (DOB NOW) — 54
DateRequirementInspectorRole
02/11/2026Protection of exposed foundation insulationEDWIN HOPKINSenergy_progress
02/11/2026Fenestration areasEDWIN HOPKINSenergy_progress
02/11/2026Insulation placement and R valuesEDWIN HOPKINSenergy_progress
02/11/2026VestibulesEDWIN HOPKINSenergy_progress
02/11/2026Fenestration and door U-factor and product ratingsEDWIN HOPKINSenergy_progress
02/11/2026Fenestration air leakageEDWIN HOPKINSenergy_progress
02/11/2026Air barrier - visual inspectionEDWIN HOPKINSenergy_progress
02/11/2026Energy Code Compliance InspectionsEDWIN HOPKINSprogress
02/11/2026Fire-Resistance Rated ConstructionEDWIN HOPKINSprogress
02/11/2026Wall Panels, Curtain Walls, and VeneersEDWIN HOPKINSspecial
02/11/2026Sprayed fire-resistant materialsEDWIN HOPKINSspecial
02/11/2026Fire-Resistant Penetrations and JointsEDWIN HOPKINSspecial
01/07/2026Fire-Resistant Penetrations and Joints—special
01/07/2026Sprayed fire-resistant materials—special
01/07/2026Wall Panels, Curtain Walls, and Veneers—special
01/07/2026Energy Code Compliance Inspections—progress
01/07/2026Fire-Resistance Rated Construction—progress
01/07/2026Fenestration areas—energy_progress
01/07/2026Air barrier - visual inspection—energy_progress
01/07/2026Fenestration air leakage—energy_progress
01/07/2026Fenestration and door U-factor and product ratings—energy_progress
01/07/2026Insulation placement and R values—energy_progress
01/07/2026Protection of exposed foundation insulation—energy_progress
01/07/2026Vestibules—energy_progress
06/13/2023Interior lighting powerEDWIN HOPKINSenergy_progress
Latest 25 of 54.
▾Documents — 65 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/17/2026X00552335-I1Request digital key ↗
08/17/2026X00552335-S7Request digital key ↗
08/17/2026X00552335-S6Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits2
▸BISBPP-5 - Authorization to the Department of Transportation1
11/21/2021240311765Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
11/23/2022240311765Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/17/2026X00552335-I1Open ↗
08/13/2026X00552335-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/17/2026X00552335-I1Open ↗
08/13/2026X00552335-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/17/2026X00552335-I1Open ↗
▸Seals & Professional Certifications22
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/24/2026X00639330-I1Open ↗
08/17/2026X00552335-S6Open ↗
08/17/2026X00552335-S5Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
08/29/2026X00552335-S3Open ↗
08/25/2026X00552335-I1Open ↗
08/25/2026X00552335-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/01/2026X00552335-S2Open ↗
08/29/2026X00552335-S3Open ↗
08/25/2026X00552335-I1Open ↗
Showing 3 of 5 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
11/21/2021240311765Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/17/2026X00552335-I1Open ↗
08/13/2026X00552335-P1Open ↗
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist2
08/17/2026X00552335-I1Open ↗
08/14/2026X00552335-P1Open ↗
▸BISSTREET TREE CHECKLIST1
11/21/2021240311765Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/17/2026X00552335-I1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026X00552335-S6Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026X00552335-S6Open ↗
▸Approvals, Objections & Sign-offs8
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter8
08/17/2026X00552335-S6Open ↗
08/17/2026X00552335-S3Open ↗
08/17/2026X00552335-I1Open ↗
Showing 3 of 8 on file for this type
▸Cost, Insurance & Ownership2
▸DOB NOWCertificate of Insurance1
08/17/2026X00552335-I1Open ↗
▸DOB NOWCertification by Insurance Broker or Agency1
08/17/2026X00552335-I1Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
11/21/2021240311765Open ↗
▸Other Documents7
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/17/2026X00552335-I1Open ↗
08/13/2026X00552335-P1Open ↗
▸DOB NOWSite Survey: Initial2
08/17/2026X00552335-I1Open ↗
08/13/2026X00552335-P1Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
11/21/2021240311765Open ↗
▸DOB NOWAdjoining Owners Notification1
08/15/2026X00552335-S2Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/17/2026X00552335-I1Open ↗