← Back
Two stories - detached, small or mid-size
123-08 111 AVENUE
QUEENS · South Ozone Park · BIN 4250614
💬 Discuss this project
1930Year Built
2Stories
A1Building Class
R3-2Zoning
1,140 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,000 sf lot · 0.38 FAR built · Flood zone X
Locations of Work
Electrical
Roof2p · 1 filing · 13 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/29/2023$685K—— → —$601/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR204/25/2025
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281204/25/2025
Building Lifecycle
All (14)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (10)
10/23/2025
Signed off — Alteration
Installation of solar panels; Rooftop, Railed, Grid tied, 25 Panels, 10.25 kW
Q01152390-I1
04/28/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
04/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
04/28/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
04/28/2025
Special inspection requirement — Final
Mina Makar
04/28/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
04/25/2025
Filed — Alteration
Installation of solar panels; Rooftop, Railed, Grid tied, 25 Panels, 10.25 kW
Q01152390-P1
04/25/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
04/25/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
04/25/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
04/25/2025
Special inspection requirement — Final
Mina Makar
04/25/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
12/11/2024
Permit issued — Solar
Q01152390-I1-SL
12/06/2024
Filed — Alteration
Installation of solar panels; Rooftop, Railed, Grid tied, 25 Panels, 10.25 kW
Q01152390-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offMOMENTUM SOLAR12/11/2024
2 projects · most recent 12/06/2024
FiledStatusContractorScope
12/06/2024CompleteISLAND ELECTRIC CORP—
09/29/2024Permit IssuedAMPACITY ELECTRICAL INC—
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
04/28/2025Structural Stability – Alterations of existing buildingsMina Makarspecial
04/28/2025Fire-Resistant Penetrations and JointsMina Makarspecial
04/28/2025Energy Code Compliance InspectionsMina Makarprogress
04/28/2025FinalMina Makarprogress
04/28/2025Air barrier - visual inspectionMina Makarenergy_progress
04/25/2025Fire-Resistant Penetrations and JointsMina Makarspecial
04/25/2025Structural Stability – Alterations of existing buildingsMina Makarspecial
04/25/2025Energy Code Compliance InspectionsMina Makarprogress
04/25/2025FinalMina Makarprogress
04/25/2025Air barrier - visual inspectionMina Makarenergy_progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01152390-P1Request digital key ↗
08/21/2026Q01152390-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
09/23/2026Q01152390-P1Open ↗
09/23/2026Q01152390-P1Open ↗
08/26/2026Q01152390-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026Q01152390-I1Open ↗
08/13/2026Q01152390-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026Q01152390-P1Open ↗
08/26/2026Q01152390-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026Q01152390-I1Open ↗
08/13/2026Q01152390-P1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01152390-I1Open ↗