| Owner | Filings | Most Recent |
|---|---|---|
| JSQS4 | 44 | 07/08/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| A&D ENGINEERING, PLLC | 8 | 08/01/2023 |
| NC2 ARCHITECTURE LLC | 5 | 03/30/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| RELIABLE EXPEDITING | 13 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| NICE PLUMBING CORP | Plumbing | 8 | 07/08/2026 |
| OMNI BUILD INC | General Contractor | 7 | 07/08/2026 |
| MEGA PLBG CORP | Fire Protection | 1 | 07/08/2026 |
| LEVEL UP PLUMBING | General Contractor | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| STEEL CORE ENGINEERING PL | 1098 | 13 | 08/01/2023 |
| TECNICO SPECIAL INSPECTIO | 5939 | 2 | 02/28/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | OMNI BUILD INC | 06/05/2023 |
| DOB NOW | Sprinklers | Signed-off | REAL PLUMBING CORP | 03/20/2023 |
| DOB NOW | Plumbing | Signed-off | NICE PLUMBING CORP | 07/29/2022 |
| DOB NOW | Mechanical Systems | Signed-off | OMNI BUILD INC | 07/15/2022 |
| DOB NOW | Structural | Signed-off | OMNI BUILD INC | 04/10/2022 |
| DOB NOW | General Construction | Permit Issued | OMNI BUILD INC | 04/08/2022 |
| DOB NOW | Plumbing | Signed-off | NICE PLUMBING CORP | 03/18/2022 |
| DOB NOW | Structural | Signed-off | OMNI BUILD INC | 03/09/2022 |
| DOB NOW | General Construction | Permit Issued | OMNI BUILD INC | 12/30/2021 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/01/2023 | Permit Issued | OMNI BUILD INC | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Daikin FXDQ07MVJU 7,500 BTU · Vrf Indoor ×12 FXAQ18PVJU 18,000 BTU · Vrf Indoor ×10 FXAQ07PVJU 7,500 BTU · Vrf Indoor ×6 FXDQ12MVJU 12,000 BTU · Vrf Indoor ×6 RXTQ60TAVJUA 57,500 BTU · Vrf Outdoor ×6 FXAQ12PVJU 12,000 BTU · Vrf Indoor ×4 FXSQ36TAVJU 36,000 BTU · Vrf Indoor ×4 RXTQ60TAVJU 57,500 BTU · Vrf Outdoor ×4 FXAQ24PVJU 24,000 BTU · Vrf Indoor ×2 Heating Daikin FXDQ07MVJU 8,500 BTU · Vrf Indoor ×12 FXAQ07PVJU 8,500 BTU · Vrf Indoor ×6 FXAQ18PVJU 20,000 BTU · Vrf Indoor ×6 FXDQ12MVJU 13,500 BTU · Vrf Indoor ×6 RXTQ60TAVJUA 57,500 BTU · Vrf Outdoor ×6 FXAQ12PVJU 13,500 BTU · Vrf Indoor ×4 FXAQ18PBVJU 20,000 BTU · Vrf Indoor ×4 FXSQ36TAVJU 40,000 BTU · Vrf Indoor ×4 RXTQ60TAVJU 57,500 BTU · Vrf Outdoor ×4 FXAQ24PVJU 27,000 BTU · Vrf Indoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/01/2023 | Signed-off | REAL PLUMBING CORP | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/01/2023 | Signed-off | LEVEL UP PLUMBING CORP | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/26/2022 | Complete | I.D.K. ELECTRIC CO., INC. | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 10/02/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 07/14/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 07/12/2023 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 07/07/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/10/2022 | Certified Storm Drainage-ST-Fixtures-Finish | Certified | View ↗ |
| 09/22/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 07/29/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 07/29/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 07/29/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 04/12/2022 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 04/12/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/28/2023 | Post-installed Anchors | Alexander Sheyman | special |
| 07/28/2023 | Fire-Resistant Penetrations and Joints | Alexander Sheyman | special |
| 07/28/2023 | HVAC-R and service water heating system controls | Alexander Sheyman | energy_progress |
| 07/28/2023 | HVAC-R and service water heating equipment | Alexander Sheyman | energy_progress |
| 07/28/2023 | HVAC-R and service water piping design and insulation | Alexander Sheyman | energy_progress |
| 07/28/2023 | Maintenance information | Alexander Sheyman | energy_progress |
| 07/28/2023 | Energy Code Compliance Inspections | Alexander Sheyman | progress |
| 07/28/2023 | Sprinkler Systems | Alexander Sheyman | special |
| 07/17/2023 | Sprinkler Systems | Alexander Sheyman | special |
| 07/17/2023 | Fire-Resistant Penetrations and Joints | Alexander Sheyman | special |
| 07/17/2023 | Maintenance information | Alexander Sheyman | energy_progress |
| 07/17/2023 | HVAC-R and service water heating system controls | Alexander Sheyman | energy_progress |
| 07/17/2023 | HVAC-R and service water piping design and insulation | Alexander Sheyman | energy_progress |
| 07/17/2023 | HVAC-R and service water heating equipment | Alexander Sheyman | energy_progress |
| 07/17/2023 | Energy Code Compliance Inspections | Alexander Sheyman | progress |
| 07/17/2023 | Post-installed Anchors | Alexander Sheyman | special |
| 07/06/2023 | HVAC-R and service water piping design and insulation | Alexander Sheyman | energy_progress |
| 07/06/2023 | HVAC-R and service water heating system controls | Alexander Sheyman | energy_progress |
| 07/06/2023 | HVAC-R and service water heating equipment | Alexander Sheyman | energy_progress |
| 07/06/2023 | Shutoff dampers | Alexander Sheyman | energy_progress |
| 07/06/2023 | Fire-Resistance Rated Construction | Alexander Sheyman | progress |
| 07/06/2023 | Final | Alexander Sheyman | progress |
| 07/06/2023 | Energy Code Compliance Inspections | Alexander Sheyman | progress |
| 07/06/2023 | Mechanical Systems | Alexander Sheyman | special |
| 07/06/2023 | Heating Systems | Alexander Sheyman | special |