← Back
Large suburban residence
123 MILTON STREET
BROOKLYN · BIN 3064855
💬 Discuss this project
1876Year Built
2Stories
A3Building Class
R6BZoning
1,622 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Large suburban residence · 1,995 sf lot · 0.81 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction1p · 2 filings · 20 docs
Floor 1Under Construction1p · 2 filings · 20 docs
CellarUnder Construction2p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
123 MILTON1009/13/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/07/2026$1.8M—— → —$1,113/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARNOLD MONTAG ARCHITECT AM/PM DESI605/11/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JOZEFKO CONSTRUCTION INCGeneral Contractor309/02/2026
SUPERB PLUMBING & HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AFM INSPECTIONS & ENGINEE4675204/03/2026
ARNOLD MONTAG ARCHITECT,4599204/03/2026
Building Lifecycle
All (40)Filed (6)Permit Issued (4)Violation (2)Objection (8)Special Inspection (20)
09/01/2026
Permit issued — Foundation
B01373592-I1-GC-CX
06/09/2026
Objection resolved — Open
06/09/2026
Objection resolved — Open
06/09/2026
Objection resolved — Open
06/09/2026
Objection resolved — Addressed
06/03/2026
Objection raised — Other
06/03/2026
Objection raised — Other
06/03/2026
Objection raised — Other
06/03/2026
Objection raised — Other
05/21/2026
Permit issued — Construction Fence
B01382163-I1-FN
05/11/2026
Filed — Alteration
PROPOSED REAR ADDITION ,EXTERIOR WINDOWS /DOOR REPLACEMENT TO ONE FAMILY,2 STORY BUILDING WITH CELLAR. ( INTERIOR ALTERATIONS THROUGHOUT FILED UNDER PRO-CERT APPLICATION # B01354308-I1
B01373592-S1
04/07/2026
Special inspection requirement — Interior lighting power
04/07/2026
Special inspection requirement — Structural Steel - Details
Anthony Marmo
04/07/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Anthony Marmo
04/07/2026
Special inspection requirement — Concrete - Cast-In-Place
Anthony Marmo
04/07/2026
Special inspection requirement — Subgrade Inspections
04/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Arnold Montag
04/07/2026
Special inspection requirement — Fire-Resistance Rated Construction
Arnold Montag
04/07/2026
Special inspection requirement — Structural Wood Frame
Arnold Montag
04/07/2026
Special inspection requirement — Energy Code Compliance Inspections
Arnold Montag
04/07/2026
Special inspection requirement — Final
Arnold Montag
04/06/2026
Filed — Alteration
Temporary construction fence filed in conjunction with B01373592
B01382163-I1
04/03/2026
Filed — Alteration
Application filed for interior alterations throughout to existing 1 family residence 2 story building with cellar. (Proposed rear addition, exterior windows /doors replacement to be filed under future separate landmark application
B01354308-P1
04/03/2026
Special inspection requirement — Interior lighting power
04/02/2026
Special inspection requirement — Subgrade Inspections
04/02/2026
Special inspection requirement — Concrete - Cast-In-Place
Anthony Marmo
04/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Arnold Montag
04/02/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Anthony Marmo
04/02/2026
Special inspection requirement — Final
Arnold Montag
04/02/2026
Special inspection requirement — Energy Code Compliance Inspections
Arnold Montag
04/02/2026
Special inspection requirement — Fire-Resistance Rated Construction
Arnold Montag
04/02/2026
Special inspection requirement — Structural Wood Frame
Arnold Montag
04/02/2026
Special inspection requirement — Structural Steel - Details
Anthony Marmo
03/30/2026
Violation issued (ECB, closed)
Construction
03/30/2026
Violation issued (ECB, closed)
Unknown
03/25/2026
Filed — Alteration
PROPOSED REAR ADDITION ,EXTERIOR WINDOWS /DOOR REPLACEMENT TO ONE FAMILY,2 STORY BUILDING WITH CELLAR. ( INTERIOR ALTERATIONS THROUGHOUT FILED UNDER PRO-CERT APPLICATION # B01354308-I1
B01373592-I1
03/18/2026
Permit issued — Plumbing
B01354308-S1-PL
02/27/2026
Filed — Alteration
Application filed for interior alterations throughout to existing 1 family residence 2 story building with cellar. (Proposed rear addition, exterior windows /doors replacement to be filed under future separate landmark application
B01354308-S1
02/26/2026
Permit issued — Structural
B01354308-I1-GC-CX
02/16/2026
Filed — Alteration
Application filed for interior alterations throughout to existing 1 family residence 2 story building with cellar. (Proposed rear addition, exterior windows /doors replacement to be filed under future separate landmark application
B01354308-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationPermit IssuedJOZEFKO CONSTRUCTION INC09/01/2026
DOB NOWConstruction FencePermit IssuedJOZEFKO CONSTRUCTION INC05/21/2026
DOB NOWPlumbingPermit IssuedSUPERB PLUMBING & HEATING03/18/2026
DOB NOWStructuralPermit IssuedJOZEFKO CONSTRUCTION INC02/26/2026
1 job · most recent 05/11/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/11/2026Permit IssuedJOZEFKO CONSTRUCTION INCHeating and Air Conditioning Systems
Heat / Cool
1 job · most recent 04/03/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/03/2026Permit IssuedSUPERB PLUMBING & HEATINGGas, Water/Sanitary
1 job · most recent 04/01/2026
FiledStatusContractorScope
04/01/2026Permit IssuedKINGS ELECTRIC CO., INC.—
2 jobs · most recent 05/11/2026
Steel Wood Concrete Masonry
FiledStatusContractorScope
05/11/2026Permit IssuedJOZEFKO CONSTRUCTION INCSteel, Concrete, Masonry, Wood
04/03/2026Permit IssuedSUPERB PLUMBING & HEATINGSteel, Wood
1 job · most recent 04/06/2026
Fence
FiledStatusContractorScope
04/06/2026Permit IssuedJOZEFKO CONSTRUCTION INCFence
▾Special Inspection Requirements (DOB NOW) — 20
DateRequirementInspectorRole
04/07/2026Interior lighting power—energy_progress
04/07/2026Structural Steel - DetailsAnthony Marmospecial
04/07/2026Structural Stability – Alterations of existing buildingsAnthony Marmospecial
04/07/2026Concrete - Cast-In-PlaceAnthony Marmospecial
04/07/2026Subgrade Inspections—special
04/07/2026Fire-Resistant Penetrations and JointsArnold Montagspecial
04/07/2026Fire-Resistance Rated ConstructionArnold Montagprogress
04/07/2026Structural Wood FrameArnold Montagprogress
04/07/2026Energy Code Compliance InspectionsArnold Montagprogress
04/07/2026FinalArnold Montagprogress
04/03/2026Interior lighting power—energy_progress
04/02/2026Subgrade Inspections—special
04/02/2026Concrete - Cast-In-PlaceAnthony Marmospecial
04/02/2026Fire-Resistant Penetrations and JointsArnold Montagspecial
04/02/2026Structural Stability – Alterations of existing buildingsAnthony Marmospecial
04/02/2026FinalArnold Montagprogress
04/02/2026Energy Code Compliance InspectionsArnold Montagprogress
04/02/2026Fire-Resistance Rated ConstructionArnold Montagprogress
04/02/2026Structural Wood FrameArnold Montagprogress
04/02/2026Structural Steel - DetailsAnthony Marmospecial
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/18/2026B01354308-I1Request digital key ↗
08/18/2026B01354308-S1Request digital key ↗
08/18/2026B01354308-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits4
▸DOB NOWLPC Approval/Permit4
08/17/2026B01373592-I1Open ↗
08/13/2026B01354308-S1Open ↗
08/13/2026B01354308-I1Open ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 13
08/17/2026B01373592-I1Open ↗
08/15/2026B01373592-S1Open ↗
08/13/2026B01354308-S1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/17/2026B01373592-I1Open ↗
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/18/2026B01354308-P1Open ↗
08/18/2026B01354308-S1Open ↗
08/18/2026B01354308-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/28/2026B01354308-P1Open ↗
08/28/2026B01354308-P1Open ↗
08/25/2026B01354308-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026B01354308-P1Open ↗
08/25/2026B01354308-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/18/2026B01354308-S1Open ↗
08/18/2026B01354308-I1Open ↗
08/18/2026B01354308-P1Open ↗
Showing 3 of 5 on file for this type
▸Other Documents3
▸DOB NOWPlot Diagram1
08/17/2026B01373592-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/17/2026B01373592-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/17/2026B01373592-I1Open ↗