Locations of Work
ArchitectureStructuralPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction30p · 1 filing · 20 docs
Floor 3Under Construction37p · 1 filing · 20 docs
Floor 2Under Construction36p · 1 filing · 20 docs
Floor 1Under Construction39p · 1 filing · 20 docs
CellarUnder Construction13p · 1 filing · 20 docs
Sub-BasementUnder Construction10p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
UNITED VENTURES2907/17/2026
STEEL CONSTRUCTION707/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/08/2023$7.7M—— → —$997/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MJE PROFESSIONAL SERVICES211/17/2025
ENGINEERING SOLUTIONS207/16/2025
MCSWEENEY ENGINEERING404/22/2025
STUDIO VURAL301/23/2025
DAVID BUCOVY ARCHITECT211/01/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SNR EXPEDITING DESIGN203/21/2026
GREEN LIGHT EXPEDITING LLC1103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DAMO CONSTRUCTION CO INCGeneral Contractor307/08/2026
STEEL CONSTRUCTION LLCGeneral Contractor207/08/2026
DJC CORPPlumbing207/17/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ARCO ENGINEERING PC3769204/22/2025
JOSEPH K. BLUM CO. LLP1741201/23/2025
DAVID BUCOVY ARCHITECT915211/01/2024
Building Lifecycle
All (83)Filed (13)Permit Issued (7)Signed Off (1)Violation (24)Inspection (5)Objection (3)Special Inspection (30)
07/16/2026
Permit issued — Plumbing
M01003737-S2-PL
11/17/2025
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M01320246-I1
11/17/2025
Filed — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M01320256-I1
11/17/2025
Permit issued — Supported Scaffold
M01320256-I1-SF
11/17/2025
Permit issued — Sidewalk Shed
M01320246-I1-SH
10/30/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/30/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
10/30/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/09/2025
Signed off — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-S3
08/29/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/29/2025
Objection raised — Scope
07/16/2025
Filed — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-P6
06/11/2025
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
04/22/2025
Filed — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-P5
04/22/2025
Filed — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-P4
04/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JOSE MANTRANA
04/15/2025
Special inspection requirement — Mechanical Systems
JOSE MANTRANA
04/15/2025
Special inspection requirement — Final
Michael McSweeney
04/15/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Michael McSweeney
04/15/2025
Special inspection requirement — Duct leakage testing, insulation and design
Michael McSweeney
04/15/2025
Special inspection requirement — HVAC-R and service water heating equipment
Michael McSweeney
04/15/2025
Special inspection requirement — Maintenance information
Michael McSweeney
04/15/2025
Special inspection requirement — HVAC-R and service water heating system controls
Michael McSweeney
02/04/2025
Special inspection requirement — Masonry
WILLIAM DEGRAAFF
02/04/2025
Special inspection requirement — Structural Steel - Details
WILLIAM DEGRAAFF
02/04/2025
Special inspection requirement — Structural Steel - High Strength Bolting
WILLIAM DEGRAAFF
02/04/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
WILLIAM DEGRAAFF
02/04/2025
Special inspection requirement — Final
WILLIAM DEGRAAFF
02/04/2025
Special inspection requirement — Structural Wood Frame
WILLIAM DEGRAAFF
02/04/2025
Special inspection requirement — Structural Steel - Welding
WILLIAM DEGRAAFF
02/04/2025
Special inspection requirement — Post-installed Anchors
WILLIAM DEGRAAFF
01/23/2025
Filed — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-P3
12/17/2024
Permit issued — Construction Fence
M01003737-S1-FN
12/17/2024
Permit issued — General Construction
M01003737-I1-GC
12/17/2024
Permit issued — Structural
M01003737-S3-ST
12/11/2024
Filed — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-S4
11/20/2024
Filed — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-P2
11/12/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
david bucovy
11/12/2024
Special inspection requirement — Fire-Resistance Rated Construction
david bucovy
11/12/2024
Special inspection requirement — Energy Code Compliance Inspections
david bucovy
11/12/2024
Special inspection requirement — Final
david bucovy
11/12/2024
Special inspection requirement — Lighting controls
SELIM VURAL
11/12/2024
Special inspection requirement — Air barrier - visual inspection
SELIM VURAL
11/12/2024
Special inspection requirement — Fenestration air leakage
SELIM VURAL
11/12/2024
Special inspection requirement — Exterior lighting power
SELIM VURAL
11/12/2024
Special inspection requirement — Insulation placement and R values
SELIM VURAL
11/12/2024
Special inspection requirement — Fenestration areas
SELIM VURAL
11/12/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
SELIM VURAL
11/12/2024
Special inspection requirement — Interior lighting power
SELIM VURAL
11/01/2024
Filed — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-P1
10/31/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
david bucovy
10/28/2024
Special inspection requirement — Lighting controls
david bucovy
07/23/2024
Permit issued — Plumbing
M01003737-S2-PL
06/24/2024
Objection resolved — Addressed
05/10/2024
Filed — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-S3
05/07/2024
Filed — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-S2
05/07/2024
Filed — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-S1
02/22/2024
Objection raised — Other
02/21/2024
Filed — Alteration
PERFORM PLUMBING MODIFICATION WORK INCONJUNCTION WITH ART STUDIO & STORE RENOVATION. REMOVE AND REPLACE PLUMBING FIXTURES. GENERAL CONSTRUCTION WORK FILED UNDER SEPERATE APPLICATION. NO CHANGE TO USE, EGRESS, OCCUPANCY OR FIRE PROTECTION.
M01003737-I1
04/02/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Latest 60 of 83 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedDJC CORP07/16/2026
DOB NOWSupported ScaffoldPermit IssuedSTEEL CONSTRUCTION LLC11/17/2025
DOB NOWSidewalk ShedPermit IssuedSTEEL CONSTRUCTION LLC11/17/2025
DOB NOWConstruction FencePermit IssuedDAMO CONSTRUCTION CO INC12/17/2024
DOB NOWGeneral ConstructionPermit IssuedDAMO CONSTRUCTION CO INC12/17/2024
DOB NOWStructuralSigned-offDAMO CONSTRUCTION CO INC12/17/2024
DOB NOWPlumbingPermit IssuedDJC CORP07/23/2024
BISPLISSUEDDJC CORP06/20/2007
1 project · most recent 07/16/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/16/2025Permit IssuedDAMO CONSTRUCTION CO INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM48NAM2 4 tons · Condensing Unit ×12
MXZ-3C24NA4 2 tons · Vrf Outdoor ×4
MXZ-SM60NAM2 5 tons · Condensing Unit ×4
1 project · most recent 07/16/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/16/2025Permit IssuedDJC CORPGas, Storm, Water/Sanitary
3 projects · most recent 11/19/2025
General Wiring
FiledStatusContractorScope
11/19/2025Permit IssuedRICHARD NEU—
05/20/2025Permit IssuedINPUT ELECTRIC CORP—
12/24/2024Permit IssuedDELTA PHASE ELEC'L CORP.General Wiring
2 projects · most recent 11/17/2025
Scaffold Sidewalk Shed
FiledStatusContractorScope
11/17/2025Permit IssuedSTEEL CONSTRUCTION LLCScaffold
11/17/2025Permit IssuedSTEEL CONSTRUCTION LLCSidewalk Shed
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/30/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/30/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/30/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/29/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/11/2025Pass-Final PL - Up to 9 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 40
DateRequirementInspectorRole
04/15/2025Fire-Resistant Penetrations and JointsJOSE MANTRANAspecial
04/15/2025Mechanical SystemsJOSE MANTRANAspecial
04/15/2025FinalMichael McSweeneyprogress
04/15/2025HVAC-R and service water piping design and insulationMichael McSweeneyenergy_progress
04/15/2025Duct leakage testing, insulation and designMichael McSweeneyenergy_progress
04/15/2025HVAC-R and service water heating equipmentMichael McSweeneyenergy_progress
04/15/2025Maintenance informationMichael McSweeneyenergy_progress
04/15/2025HVAC-R and service water heating system controlsMichael McSweeneyenergy_progress
02/04/2025MasonryWILLIAM DEGRAAFFspecial
02/04/2025Structural Steel - DetailsWILLIAM DEGRAAFFspecial
02/04/2025Structural Steel - High Strength BoltingWILLIAM DEGRAAFFspecial
02/04/2025Structural Stability – Alterations of existing buildingsWILLIAM DEGRAAFFspecial
02/04/2025FinalWILLIAM DEGRAAFFprogress
02/04/2025Structural Wood FrameWILLIAM DEGRAAFFprogress
02/04/2025Structural Steel - WeldingWILLIAM DEGRAAFFspecial
02/04/2025Post-installed AnchorsWILLIAM DEGRAAFFspecial
11/12/2024Fire-Resistant Penetrations and Jointsdavid bucovyspecial
11/12/2024Fire-Resistance Rated Constructiondavid bucovyprogress
11/12/2024Energy Code Compliance Inspectionsdavid bucovyprogress
11/12/2024Finaldavid bucovyprogress
11/12/2024Lighting controlsSELIM VURALenergy_progress
11/12/2024Air barrier - visual inspectionSELIM VURALenergy_progress
11/12/2024Fenestration air leakageSELIM VURALenergy_progress
11/12/2024Exterior lighting powerSELIM VURALenergy_progress
11/12/2024Insulation placement and R valuesSELIM VURALenergy_progress
Latest 25 of 40.
▾Documents — 63 on file (BIS + DOB NOW)
▸Plans & Drawings13
▸DOB NOWPlans/Sketch13
08/22/2026M01003737-S4Request digital key ↗
08/22/2026M01003737-S3Request digital key ↗
08/22/2026M01003737-S2Request digital key ↗
Showing 3 of 13 on file for this type
▸Seals & Professional Certifications31
▸DOB NOWDPL-1: Design Professional Seal & Signature13
08/22/2026M01003737-S4Open ↗
08/22/2026M01003737-S3Open ↗
08/22/2026M01003737-S2Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
08/28/2026M01003737-P5Open ↗
08/28/2026M01003737-P5Open ↗
08/28/2026M01003737-P5Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
08/25/2026M01003737-I1Open ↗
08/24/2026M01003737-S3Open ↗
08/24/2026M01003737-S3Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos17
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/22/2026M01003737-S3Open ↗
08/22/2026M01003737-S2Open ↗
08/22/2026M01003737-P4Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWOER: Notice to Proceed8
08/22/2026M01003737-S2Open ↗
08/13/2026M01003737-P3Open ↗
08/13/2026M01003737-S2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWOER: Notice of Satisfaction1
08/13/2026M01003737-S3Open ↗
▸Other Documents2
▸DOB NOWWaiver Document2
08/22/2026M01003737-S2Open ↗
08/13/2026M01003737-I1Open ↗