← Back
Three families
123 WEST 122 STREET
MANHATTAN · Harlem (South) · BIN 1057719
💬 Discuss this project
1885Year Built
3Stories
C0Building Class
R7-2Zoning
4,012 sfGross Floor Area
3Units
Rent Stabilized0 Open Violations
Three families · 1,875 sf lot · 2.14 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 329p · 1 filing · 20 docs
Floor 225p · 1 filing · 20 docs
Floor 119p · 1 filing · 20 docs
Cellar30p · 1 filing · 20 docs
Basement18p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SKYWORX CONTRACTING INC103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/23/2021$1.4M—Private party → Private party$349/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VICTOR RUIZ ARCHITECTURE908/02/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BONILLA & SONS INCGeneral Contractor403/21/2026
SYED-NAQVI ALTAFElectrical103/21/2026
SYED-NAQVI, ALTAFElectrical103/21/2026
DNA PLUMBING CONTR. INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
VICTOR RUIZ ARCHITECTURE,5884908/02/2024
Building Lifecycle
All (52)Filed (8)Permit Issued (3)Signed Off (1)Violation (16)Inspection (6)Special Inspection (18)
08/26/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/20/2024
Special inspection requirement — Lighting in dwelling units
VICTOR RUIZ
08/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
VICTOR RUIZ
08/20/2024
Special inspection requirement — Fenestration air leakage
VICTOR RUIZ
08/20/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
VICTOR RUIZ
08/20/2024
Special inspection requirement — Insulation placement and R values
VICTOR RUIZ
08/20/2024
Special inspection requirement — Air barrier - visual inspection
VICTOR RUIZ
08/02/2024
Filed — Alteration CO
PLUMBING WORK FOR CONVERSION FORM 3-FAMILY TO TWO-FAMILY: CAP AND REMOVE ONE KITCHEN, MINOR ALTERATION OF ONE BATHROOM, AND GAS METER WORK TO CONFIGURE FOR TWO APARTMENT METERS AND ONE HOUSE METER.
M00679188-P7
08/02/2024
Special inspection requirement — Fenestration air leakage
VICTOR RUIZ
08/02/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
VICTOR RUIZ
08/02/2024
Special inspection requirement — Air barrier - visual inspection
VICTOR RUIZ
08/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
VICTOR RUIZ
08/02/2024
Special inspection requirement — Insulation placement and R values
VICTOR RUIZ
08/02/2024
Special inspection requirement — Lighting in dwelling units
VICTOR RUIZ
05/28/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/01/2024
Violation issued (HPD, closed)
A
03/28/2024
Filed — Alteration CO
PLUMBING WORK FOR CONVERSION FORM 3-FAMILY TO TWO-FAMILY: CAP AND REMOVE ONE KITCHEN, MINOR ALTERATION OF ONE BATHROOM, AND GAS METER WORK TO CONFIGURE FOR TWO APARTMENT METERS AND ONE HOUSE METER.
M00679188-P6
12/05/2023
Signed off — Alteration CO
PLUMBING WORK FOR CONVERSION FORM 3-FAMILY TO TWO-FAMILY: CAP AND REMOVE ONE KITCHEN, MINOR ALTERATION OF ONE BATHROOM, AND GAS METER WORK TO CONFIGURE FOR TWO APARTMENT METERS AND ONE HOUSE METER.
M00679188-S1
11/15/2023
Violation issued (HPD, closed)
I
10/31/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
VICTOR RUIZ
09/21/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/18/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
VICTOR RUIZ
09/14/2023
Filed — Alteration CO
PLUMBING WORK FOR CONVERSION FORM 3-FAMILY TO TWO-FAMILY: CAP AND REMOVE ONE KITCHEN, MINOR ALTERATION OF ONE BATHROOM, AND GAS METER WORK TO CONFIGURE FOR TWO APARTMENT METERS AND ONE HOUSE METER.
M00679188-P4
09/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
VICTOR RUIZ
09/13/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/08/2023
Filed — Alteration CO
PLUMBING WORK FOR CONVERSION FORM 3-FAMILY TO TWO-FAMILY: CAP AND REMOVE ONE KITCHEN, MINOR ALTERATION OF ONE BATHROOM, AND GAS METER WORK TO CONFIGURE FOR TWO APARTMENT METERS AND ONE HOUSE METER.
M00679188-P3
08/16/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
08/16/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
VICTOR RUIZ
08/10/2023
Filed — Alteration CO
PLUMBING WORK FOR CONVERSION FORM 3-FAMILY TO TWO-FAMILY: CAP AND REMOVE ONE KITCHEN, MINOR ALTERATION OF ONE BATHROOM, AND GAS METER WORK TO CONFIGURE FOR TWO APARTMENT METERS AND ONE HOUSE METER.
M00679188-P2
08/10/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
VICTOR RUIZ
07/05/2023
Permit issued — General Construction
M00679188-I1-GC
06/25/2023
Filed — Alteration CO
PLUMBING WORK FOR CONVERSION FORM 3-FAMILY TO TWO-FAMILY: CAP AND REMOVE ONE KITCHEN, MINOR ALTERATION OF ONE BATHROOM, AND GAS METER WORK TO CONFIGURE FOR TWO APARTMENT METERS AND ONE HOUSE METER.
M00679188-P1
06/25/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
VICTOR RUIZ
06/21/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/06/2023
Permit issued — Plumbing
M00679188-S1-PL
06/01/2023
Filed — Alteration CO
PLUMBING WORK FOR CONVERSION FORM 3-FAMILY TO TWO-FAMILY: CAP AND REMOVE ONE KITCHEN, MINOR ALTERATION OF ONE BATHROOM, AND GAS METER WORK TO CONFIGURE FOR TWO APARTMENT METERS AND ONE HOUSE METER.
M00679188-S1
03/16/2023
Violation issued (HPD, closed)
A
03/09/2023
Permit issued — General Construction
M00679188-I1-GC
11/22/2022
Filed — Alteration CO
PLUMBING WORK FOR CONVERSION FORM 3-FAMILY TO TWO-FAMILY: CAP AND REMOVE ONE KITCHEN, MINOR ALTERATION OF ONE BATHROOM, AND GAS METER WORK TO CONFIGURE FOR TWO APARTMENT METERS AND ONE HOUSE METER.
M00679188-I1
02/16/2022
Violation issued (HPD, closed)
A
04/02/2021
Violation issued (HPD, closed)
A
09/19/2014
Violation issued (ECB, closed)
Unknown
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedBONILLA SONS07/05/2023
DOB NOWPlumbingSigned-offDNA PLUMBING CONTR. INC06/06/2023
DOB NOWGeneral ConstructionPermit IssuedBONILLA SONS03/09/2023
BISMHISSUEDBONILLA & SONS INC09/10/2018
BISMHISSUEDRUBEN REFRIGERATION & AC07/19/2017
BISPLISSUEDPRECISION PLBG SVCS., INC12/06/2016
BISOTISSUEDBONILLA & SONS INC09/18/2015
BISPLISSUEDPRECISION PLBG SVCS., INC10/02/2014
BISOTISSUEDBONILLA & SONS INC09/16/2014
BISOTISSUEDBONILLA & SONS INC07/10/2014
BISOTISSUEDBONILLA & SONS INC07/03/2014
BISOTISSUEDBONILLA & SONS INC04/14/2014
BISEQISSUEDSKYWORX CONTRACTING INC06/12/2013
BISEQISSUEDSKYWORX CONTRACTING INC06/12/2013
BISSPISSUEDTHE PLUMBING COMPANY INC01/19/2006
BISPLISSUEDTHE PLBG COMPANY INC09/19/2003
BIS—ISSUEDBUDIMEX GENERAL_CONTRACTING INC09/10/2003
1 project · most recent 06/25/2024
FiledStatusContractorScope
06/25/2024CompleteINFINITI ELECTRIC CORP—
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
08/26/2024Pass-Final CND-Occupancy InspectionPassView ↗
05/28/2024Pass-Final CND-Occupancy InspectionPassView ↗
09/21/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/13/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/16/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
06/21/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
08/20/2024Lighting in dwelling unitsVICTOR RUIZenergy_progress
08/20/2024Fire-Resistant Penetrations and JointsVICTOR RUIZspecial
08/20/2024Fenestration air leakageVICTOR RUIZenergy_progress
08/20/2024Fenestration and door U-factor and product ratingsVICTOR RUIZenergy_progress
08/20/2024Insulation placement and R valuesVICTOR RUIZenergy_progress
08/20/2024Air barrier - visual inspectionVICTOR RUIZenergy_progress
08/02/2024Fenestration air leakageVICTOR RUIZenergy_progress
08/02/2024Fenestration and door U-factor and product ratingsVICTOR RUIZenergy_progress
08/02/2024Air barrier - visual inspectionVICTOR RUIZenergy_progress
08/02/2024Fire-Resistant Penetrations and JointsVICTOR RUIZspecial
08/02/2024Insulation placement and R valuesVICTOR RUIZenergy_progress
08/02/2024Lighting in dwelling unitsVICTOR RUIZenergy_progress
10/31/2023Fire-Resistant Penetrations and JointsVICTOR RUIZspecial
09/18/2023Fire-Resistant Penetrations and JointsVICTOR RUIZspecial
09/14/2023Fire-Resistant Penetrations and JointsVICTOR RUIZspecial
08/16/2023Fire-Resistant Penetrations and JointsVICTOR RUIZspecial
08/10/2023Fire-Resistant Penetrations and JointsVICTOR RUIZspecial
06/25/2023Fire-Resistant Penetrations and JointsVICTOR RUIZspecial
▾Documents — 147 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
09/06/2026M00679188-S1Request digital key ↗
09/06/2026M00679188-I1Request digital key ↗
09/06/2026M00679188-P7Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits38
▸BISPLAN / WORK APPROVAL APPLICATION20
08/02/2024121679399Open ↗
08/02/2024121679406Open ↗
07/31/2024121679399Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWLPC Approval/Permit9
08/13/2026M00679188-I1Open ↗
08/13/2026M00679188-S1Open ↗
08/13/2026M00679188-P7Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION8
09/10/2018121939448Open ↗
07/26/2017122022284Open ↗
12/15/2016122022284Open ↗
Showing 3 of 8 on file for this type
▸BISINTENT TO REVOKE APPROVAL/PERMIT1
12/06/2018121939448Open ↗
▸Seals & Professional Certifications40
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION15
09/24/2018121939448Open ↗
09/24/2018121939448Open ↗
09/24/2018121939448Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/06/2026M00679188-I1Open ↗
09/06/2026M00679188-P2Open ↗
09/06/2026M00679188-P7Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/02/2026M00679188-P1Open ↗
08/30/2026M00679188-S1Open ↗
08/28/2026M00679188-P3Open ↗
Showing 3 of 8 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
04/03/2014121939448Open ↗
06/18/2013121679406Open ↗
06/18/2013121679399Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
06/18/2013121679406Open ↗
06/18/2013121679399Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026M00679188-P7Open ↗
08/26/2026M00679188-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
04/03/2014121939448Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE4
05/10/2017122022284Open ↗
04/13/2017122022284Open ↗
04/03/2017122022284Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING1
07/23/2014122022284Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist3
09/06/2026M00679188-I1Open ↗
09/06/2026M00679188-P7Open ↗
09/06/2026M00679188-P6Open ↗
▸BISSRO MD ANTI-HARASSMENT CHECKLIST2
06/18/2013121679399Open ↗
06/18/2013121679406Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
09/06/2026M00679188-I1Open ↗
09/06/2026M00679188-P7Open ↗
09/06/2026M00679188-P6Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/03/2014121939448Open ↗
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
07/23/2014122022284Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
07/05/2024121679406Open ↗
07/05/2024121679399Open ↗
▸Approvals, Objections & Sign-offs13
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
08/02/2024121679406Open ↗
08/02/2024121679399Open ↗
09/24/2018121939448Open ↗
Showing 3 of 4 on file for this type
▸BISLANDMARKS APPROVAL3
08/01/2018121939448Open ↗
10/27/2017122022284Open ↗
12/01/2016122022284Open ↗
▸BISFINAL2
08/02/2024121679406Open ↗
08/02/2024121679399Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
06/18/2013121679406Open ↗
06/18/2013121679399Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
04/17/2014121939448Open ↗
▸BISLANDMARKS SIGNOFF1
09/24/2018121939448Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
09/24/2018121939448Open ↗
10/27/2017122022284Open ↗
07/23/2014122022284Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms15
▸BISADDITIONAL INFORMATION8
09/04/2018121939448Open ↗
08/01/2018121939448Open ↗
12/01/2016122022284Open ↗
Showing 3 of 8 on file for this type
▸BISEFILING COVER SHEET4
07/23/2014122022284Open ↗
04/03/2014121939448Open ↗
06/18/2013121679406Open ↗
Showing 3 of 4 on file for this type
▸BISBOROUGH INTAKE FORM3
09/24/2018121939448Open ↗
08/27/2018121939448Open ↗
10/27/2017122022284Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification3
09/06/2026M00679188-I1Open ↗
09/06/2026M00679188-P7Open ↗
09/06/2026M00679188-P6Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
11/22/2017121939448Open ↗
▸BISDepartment of Consumer Affairs (DCA) Form1
07/17/2014122022284Open ↗