← Back
Three families
1236 BAY RIDGE PARKWAY
BROOKLYN · Dyker Heights · BIN 3159940
💬 Discuss this project
1910Year Built
3Stories
C0Building Class
R4-1Zoning
3,232 sfGross Floor Area
3Units
Rent Stabilized10 Open Violations ▸FDNY Report ↗
Three families · 4,000 sf lot · 0.81 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 3Under Construction9p · 2 filings · 20 docs
Floor 2Under Construction11p · 2 filings · 20 docs
Floor 1Under Construction15p · 2 filings · 20 docs
CellarUnder Construction15p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KALE CONSTRUCTION103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/31/2024$1.6M—Private party → Private party$511/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BAYSIDE ENGINEERING PC905/08/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
H J BUILDING CONSULTING1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KALE CONSTRUCTION INCGeneral Contractor204/08/2026
FLINT MECHANICAL CORPPlumbing107/08/2026
JADA PLUMBING & HTG LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S7010905/08/2026
Building Lifecycle
All (90)Filed (9)Permit Issued (4)Violation (18)Inspection (9)Objection (20)Special Inspection (30)
08/03/2026
Violation issued (ECB, open)
Construction
05/28/2026
Special inspection requirement — Maintenance information
XIUCHENG LI
05/28/2026
Special inspection requirement — Interior lighting power
XIUCHENG LI
05/28/2026
Special inspection requirement — Lighting controls
XIUCHENG LI
05/28/2026
Special inspection requirement — Fire-Resistance Rated Construction
XIUCHENG LI
05/28/2026
Special inspection requirement — Air barrier - visual inspection
XIUCHENG LI
05/28/2026
Special inspection requirement — Fenestration areas
XIUCHENG LI
05/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
05/28/2026
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
05/28/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
XIUCHENG LI
05/28/2026
Special inspection requirement — Fenestration air leakage
XIUCHENG LI
05/28/2026
Special inspection requirement — Chimneys and vents
XIUCHENG LI
05/28/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
XIUCHENG LI
05/28/2026
Special inspection requirement — Permanent certificate
XIUCHENG LI
05/28/2026
Special inspection requirement — Lighting in dwelling units
XIUCHENG LI
05/20/2026
Special inspection requirement — Permanent certificate
XIUCHENG LI
05/20/2026
Special inspection requirement — Lighting controls
XIUCHENG LI
05/20/2026
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
05/20/2026
Special inspection requirement — Interior lighting power
XIUCHENG LI
05/20/2026
Special inspection requirement — Maintenance information
XIUCHENG LI
05/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
XIUCHENG LI
05/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
05/20/2026
Special inspection requirement — Lighting in dwelling units
XIUCHENG LI
05/19/2026
Objection resolved — Addressed
05/18/2026
Objection raised — Other
05/08/2026
Filed — Alteration
INTERIOR RENOVATION AT CELLAR AND 1ST FLOOR OF EXISTING 3 STORY BUILDING WITH GENERAL CONSTRUCTION WORK AS PER PLANS FILED HEREWITH. RELATED PLUMBING WORK WILL BE FILED SEPARATELY. TO RESOLVE ECB#39123672X,39183905M. NO CHANGE IN USE, EGRESS OR C OF O..
B01115026-P2
05/08/2026
Filed — Alteration
INTERIOR RENOVATION ON 2ND & 3RD FLOOR OF EXISTING 3 STORY BUILDING WITH GENERAL CONSTRUCTION WORK AS PER PLANS FILED HEREWITH. RELATED PLUMBING WORK WILL BE FILED SEPARATELY. TO RESOLVE ECB#39123672X. NO CHANGE IN USE, EGRESS OR C OF O..
B01115045-P2
05/08/2026
Filed — Alteration
PLUMBING WORK AT EXISTING 3 STORY BUILDING AS PER PLANS FILED HEREWITH. RELATED GENERAL CONSTRUCTION HAS BEEN FILED SEPARATELY IN DOB NOW JOB#B01115026-I1&B01115045-I1. TO RESOLVE ECB#39123672X. NO CHANGE IN USE, EGRESS OR C OF O..
B01115046-P2
05/07/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/06/2026
Special inspection requirement — Interior lighting power
XIUCHENG LI
05/06/2026
Special inspection requirement — Maintenance information
XIUCHENG LI
05/06/2026
Special inspection requirement — Permanent certificate
XIUCHENG LI
05/06/2026
Special inspection requirement — Lighting controls
XIUCHENG LI
05/06/2026
Special inspection requirement — Lighting in dwelling units
XIUCHENG LI
05/06/2026
Special inspection requirement — Fire-Resistance Rated Construction
XIUCHENG LI
05/06/2026
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
05/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
05/01/2026
Violation issued (HPD, open)
A
04/27/2026
Permit issued — Plumbing
B01115046-I1-PL
04/09/2026
Violation issued (ECB, closed)
Construction
11/21/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/20/2025
Violation issued (HPD, open)
I
08/28/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/08/2025
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
06/28/2025
Violation issued (ECB, open)
Construction
06/24/2025
Violation issued (ECB, closed)
Construction
06/20/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/09/2025
Objection resolved — Addressed
06/06/2025
Violation issued (HPD, open)
A
06/06/2025
Objection resolved — Addressed
06/06/2025
Objection resolved — Addressed
06/06/2025
Objection resolved — Addressed
06/03/2025
Objection raised — Other
05/30/2025
Objection raised — Other
05/30/2025
Objection raised — Other
05/30/2025
Objection raised — Other
05/30/2025
Objection resolved — Addressed
05/29/2025
Objection raised — Cost
05/20/2025
Objection resolved — Addressed
05/19/2025
Objection raised — Other
Latest 60 of 90 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedJADA PLUMBING & HTG LLC04/27/2026
DOB NOWPlumbingPermit IssuedFLINT MECHANICAL CORP11/29/2024
DOB NOWGeneral ConstructionPermit IssuedKALE CONSTRUCTION INC11/29/2024
DOB NOWGeneral ConstructionPermit IssuedKALE CONSTRUCTION INC11/27/2024
BISPLISSUEDHENRY MYERS P & H, INC06/11/2024
BISPLISSUEDGENCO PLBG & HTG CO10/19/2012
BISOTISSUEDKALINA CONSTRUCTION INC02/08/2011
BISPLISSUEDGENCO PLBG & HTG CO01/28/2011
1 project · most recent 05/08/2026
Gas Water/Sanitary
FiledStatusContractorScope
05/08/2026Permit IssuedJADA PLUMBING & HTG LLCGas, Water/Sanitary
3 projects · most recent 05/26/2025
General Wiring
FiledStatusContractorScope
05/26/2025Permit IssuedJ Y ELECTRIC INC4 meters, 4 new_meters
04/04/2025Permit IssuedJ Y ELECTRIC INCGeneral Wiring
11/16/2024Permit IssuedJ Y ELECTRIC INC—
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
05/07/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/21/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/28/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/08/2025Pass-Final PL - Up to 9 Requested FloorsPassView ↗
06/20/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/18/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/18/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/27/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/27/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 65
DateRequirementInspectorRole
05/28/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
05/28/2026Structural Stability – Alterations of existing buildingsXIUCHENG LIspecial
05/28/2026Chimneys and ventsXIUCHENG LIspecial
05/28/2026Fire-Resistance Rated ConstructionXIUCHENG LIprogress
05/28/2026Energy Code Compliance InspectionsXIUCHENG LIprogress
05/28/2026Fenestration areasXIUCHENG LIenergy_progress
05/28/2026Permanent certificateXIUCHENG LIenergy_progress
05/28/2026Maintenance informationXIUCHENG LIenergy_progress
05/28/2026Fenestration air leakageXIUCHENG LIenergy_progress
05/28/2026Lighting controlsXIUCHENG LIenergy_progress
05/28/2026Fenestration and door U-factor and product ratingsXIUCHENG LIenergy_progress
05/28/2026Interior lighting powerXIUCHENG LIenergy_progress
05/28/2026Lighting in dwelling unitsXIUCHENG LIenergy_progress
05/28/2026Air barrier - visual inspectionXIUCHENG LIenergy_progress
05/20/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
05/20/2026Energy Code Compliance InspectionsXIUCHENG LIprogress
05/20/2026Fire-Resistance Rated ConstructionXIUCHENG LIprogress
05/20/2026Maintenance informationXIUCHENG LIenergy_progress
05/20/2026Interior lighting powerXIUCHENG LIenergy_progress
05/20/2026Permanent certificateXIUCHENG LIenergy_progress
05/20/2026Lighting controlsXIUCHENG LIenergy_progress
05/20/2026Lighting in dwelling unitsXIUCHENG LIenergy_progress
05/06/2026Fire-Resistance Rated ConstructionXIUCHENG LIprogress
05/06/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
05/06/2026Energy Code Compliance InspectionsXIUCHENG LIprogress
Latest 25 of 65.
▾Documents — 116 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/21/2026B01115045-P1Request digital key ↗
08/21/2026B01115045-I1Request digital key ↗
08/21/2026B01115045-P2Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits6
▸BISWORK PERMIT APPLICATION4
06/17/2024320251142Open ↗
10/23/2012320251142Open ↗
02/10/2011320251142Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
06/03/2024320251142Open ↗
12/13/2010320251142Open ↗
▸Seals & Professional Certifications75
▸DOB NOWProgress Inspector Seal & Signature53
09/01/2026B01115045-P1Open ↗
09/01/2026B01115045-P1Open ↗
09/01/2026B01115045-P1Open ↗
Showing 3 of 53 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/01/2026B01115045-P1Open ↗
09/01/2026B01115045-P1Open ↗
09/01/2026B01115045-P1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/21/2026B01115045-I1Open ↗
08/21/2026B01115045-P2Open ↗
08/21/2026B01115045-P1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
12/13/2010320251142Open ↗
▸Trade Schedules & Equipment3
▸BISSELF-CERT PLUMBING NOTICE2
03/22/2011320251142Open ↗
03/07/2011320251142Open ↗
▸BISSCHEDULE B - PLUMBING1
12/13/2010320251142Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
12/13/2010320251142Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/21/2026B01115045-I1Open ↗
08/21/2026B01115045-P2Open ↗
08/21/2026B01115045-P1Open ↗
Showing 3 of 9 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
12/13/2010320251142Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
06/24/2024320251142Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
06/24/2024320251142Open ↗
▸Inspections & Test Reports2
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
06/24/2024320251142Open ↗
▸BISMECHANICAL SYSTEMS1
06/24/2024320251142Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/25/2024320251142Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
12/13/2010320251142Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
06/17/2024320251142Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT (FINAL): PW32
06/24/2024320251142Open ↗
06/24/2024320251142Open ↗
▸BISCOST AFFIDAVIT1
12/13/2010320251142Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
12/13/2010320251142Open ↗
▸Other Documents1
▸BISCHIMNEYS AND VENTS1
06/24/2024320251142Open ↗