← Back
Over six families without stores
124 EAST 103 STREET
MANHATTAN · East Harlem (South) · BIN 1051902
💬 Discuss this project
1910Year Built
6Stories
C1Building Class
R7-2Zoning
—Gross Floor Area
30Units
84 Open Violations 83 unresolved · 1 paperwork only ▸FDNY Report ↗
Over six families without stores · Owner of record: 124 EAST 103 LLC · 4.04 FAR built · Flood zone X
Locations of Work
Architecture
Site & exterior1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ARCH ROCK GROUP403/21/2026
Colliers International208/29/2026
124 EAST 103 LLC203/22/2026
R E MANAGEMENT203/21/2026
E+M MANAGEMENT203/21/2026
E & M ASSOCIATES103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
O&S ASSOCIATES106/01/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HECTOR MEJIAElectrical103/21/2026
MAYER WEBERElectrical103/21/2026
PHILIP ZUARDIElectrical103/21/2026
WEBER, MAYERElectrical103/21/2026
AJL BUILDERS, CORPGeneral Contractor107/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
O&S ASSOCIATES2753106/01/2026
TECTONIC ENGINEERING CONS106106/01/2026
Building Lifecycle
All (66)Filed (1)Permit Issued (1)Violation (60)Special Inspection (4)
08/20/2026
Violation issued (HPD, open)
C
08/20/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
C
07/27/2026
Permit issued — General Construction
M01383736-I1-GC-CX
06/01/2026
Filed — Alteration
Herewith filing to remove and reinstall a retaining wall and adjacent soil in the rear yard. No change to use, egress or occupancy.
M01383736-I1
04/29/2026
Violation issued (HPD, open)
A
04/07/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SUCHITH JAYASENA
04/07/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
GEORGE GHEBRYAL
04/07/2026
Special inspection requirement — Tenant Protection Plan Compliance
SUCHITH JAYASENA
04/07/2026
Special inspection requirement — Final
SUCHITH JAYASENA
03/02/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/02/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/28/2026
Violation issued (ECB, open)
Construction
02/28/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/28/2026
Violation issued (HPD, closed)
C
01/28/2026
Violation issued (HPD, open)
B
01/28/2026
Violation issued (HPD, open)
B
12/29/2025
Violation issued (HPD, open)
C
12/29/2025
Violation issued (HPD, open)
C
12/29/2025
Violation issued (HPD, open)
C
12/29/2025
Violation issued (HPD, open)
C
12/29/2025
Violation issued (HPD, closed)
C
12/05/2025
Violation issued (HPD, open)
B
12/05/2025
Violation issued (HPD, open)
B
12/05/2025
Violation issued (HPD, open)
A
12/05/2025
Violation issued (HPD, open)
C
12/03/2025
Violation issued (HPD, open)
B
12/03/2025
Violation issued (HPD, open)
B
12/03/2025
Violation issued (HPD, open)
B
12/03/2025
Violation issued (HPD, open)
A
12/03/2025
Violation issued (HPD, closed)
A
09/22/2025
Violation issued (HPD, open)
B
09/22/2025
Violation issued (HPD, open)
B
05/04/2025
Violation issued (HPD, closed)
C
05/04/2025
Violation issued (HPD, open)
C
05/04/2025
Violation issued (HPD, open)
C
05/04/2025
Violation issued (HPD, open)
C
05/04/2025
Violation issued (HPD, open)
C
05/04/2025
Violation issued (HPD, open)
C
04/08/2025
Violation issued (ECB, open)
Boilers
03/24/2025
Violation issued (HPD, closed)
C
10/11/2024
Violation issued (HPD, closed)
B
06/11/2024
Violation issued (HPD, open)
C
06/11/2024
Violation issued (HPD, closed)
B
06/11/2024
Violation issued (HPD, closed)
B
06/11/2024
Violation issued (HPD, closed)
C
06/11/2024
Violation issued (HPD, closed)
A
06/11/2024
Violation issued (HPD, closed)
B
06/11/2024
Violation issued (HPD, closed)
C
06/11/2024
Violation issued (HPD, closed)
A
06/04/2024
Violation issued (HPD, closed)
B
06/04/2024
Violation issued (HPD, closed)
A
06/04/2024
Violation issued (HPD, open)
C
06/04/2024
Violation issued (HPD, closed)
A
06/04/2024
Violation issued (HPD, closed)
C
06/04/2024
Violation issued (HPD, closed)
C
06/04/2024
Violation issued (HPD, closed)
C
06/04/2024
Violation issued (HPD, closed)
B
06/04/2024
Violation issued (HPD, closed)
B
06/04/2024
Violation issued (HPD, closed)
C
Latest 60 of 66 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offAJL BUILDERS, CORP07/27/2026
BISOTISSUEDBO7 CONSTRUCTION CORP03/27/2018
BISPLISSUEDPRECISION PLBG SVCS., INC02/01/2018
BISPLRE-ISSUEDPRECISION PLBG SVCS., INC12/27/2017
BISOTISSUEDBO7 CONSTRUCTION CORP12/07/2017
BISOTISSUEDLAND DESIGN STUDIO INC05/11/2017
BISBLISSUEDCAM ENERGY HTG AND MECH04/11/2014
BISFBISSUEDCASTLE OIL CORPORATION12/12/2000
2 projects · most recent 05/09/2018
General Wiring
FiledStatusContractorScope
05/09/2018CompleteCOUNTY ELECL CONTRACTOR IGeneral Wiring
12/27/2017Permit IssuedHECMAR ELECTRICGeneral Wiring
1 project · most recent 06/01/2026
FiledStatusContractorScope
06/01/2026Signed-offAJL BUILDERS, CORP1 scope_items
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
04/07/2026Structural Stability – Alterations of existing buildingsSUCHITH JAYASENAspecial
04/07/2026Subsurface Conditions – Fill Placement & In-Place DensityGEORGE GHEBRYALspecial
04/07/2026Tenant Protection Plan ComplianceSUCHITH JAYASENAspecial
04/07/2026FinalSUCHITH JAYASENAprogress
▾Documents — 43 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/17/2026M01383736-I1Request digital key ↗
▸Applications & Permits12
▸BISWORK PERMIT APPLICATION9
03/29/2018123056815Open ↗
02/01/2018123020685Open ↗
02/01/2018123056815Open ↗
Showing 3 of 9 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
07/07/2017123056815Open ↗
05/17/2017123020685Open ↗
04/10/2014140176173Open ↗
▸Seals & Professional Certifications9
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
07/07/2017123056815Open ↗
05/17/2017123020685Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/22/2026M01383736-I1Open ↗
08/22/2026M01383736-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
04/10/2014140176173Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/10/2014140176173Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
04/10/2014140176173Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/17/2026M01383736-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/22/2026M01383736-I1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
07/07/2017123056815Open ↗
05/17/2017123020685Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
04/10/2014140176173Open ↗
▸Safety & Tenant Protection2
▸BISTenant Protection Plan and Notes2
07/07/2017123056815Open ↗
05/17/2017123020685Open ↗
▸Environmental & Asbestos4
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
07/07/2017123056815Open ↗
05/17/2017123020685Open ↗
05/17/2017123020685Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
07/07/2017123056815Open ↗
05/17/2017123020685Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
04/10/2014140176173Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
04/10/2014140176173Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
04/10/2014140176173Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
07/07/2017123056815Open ↗
05/17/2017123020685Open ↗
04/10/2014140176173Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
07/07/2017123056815Open ↗
05/17/2017123020685Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/10/2014140176173Open ↗
▸Other Documents1
▸DOB NOWAdjoining Owners Notification1
08/17/2026M01383736-I1Open ↗