| Owner | Filings | Most Recent |
|---|---|---|
| 124 WEST 109TH STREET | 3 | 03/21/2026 |
| 124 W 109 ST CORP | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| EP ENGINEERING LLC | 4 | 10/21/2024 |
| HEITLER HOUSTOUN ARCHITECTS | 4 | 06/25/2024 |
| MADSEN CONSULTING ENGINEERING, PLLC | 2 | 02/29/2024 |
| RODRIGUEZ STUDIO ARCHITECTURE PC | 2 | 08/01/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| PAUL FUSCO CONSULTING | 20 | 03/21/2026 |
| GREEN LIGHT EXPEDITING LLC | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| WIESLAW MAKSIM | Electrical | 4 | 03/21/2026 |
| COOLQUEST MECHANICAL INC | General Contractor | 3 | 03/21/2026 |
| J.K. REMODELING INC | General Contractor | 3 | 07/08/2026 |
| ASR ENGINEERING PC | Electrical | 1 | 03/21/2026 |
| DENMAR ELECTRIC CORP | Electrical | 1 | 03/22/2026 |
| A.M.N. CORPORATION | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| EP INSPECTIONS AND COMMIS | 7079 | 4 | 06/25/2024 |
| MADSEN ENGINEERING | 5423 | 2 | 02/29/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Structural | Signed-off | J.K. REMODELING INC | 03/01/2024 |
| DOB NOW | General Construction | Signed-off | J.K. REMODELING INC | 02/28/2024 |
| DOB NOW | Mechanical Systems | Signed-off | COOLQUEST MECHANICAL INC | 02/27/2024 |
| DOB NOW | Plumbing | Signed-off | A.M.N. CORPORATION | 02/26/2024 |
| BIS | PL | ISSUED | THE RIGHT CONNECTION P&H | 04/09/2001 |
| BIS | OT | ISSUED | ARTIES HOME IMPROVEMENT CORP | 03/22/2001 |
| BIS | OT | ISSUED | SAME | 11/21/1994 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/21/2024 | Signed-off | J.K. REMODELING INC | Air Conditioning Systems | Cooling Mitsubishi Electric PEFY-P12NMAU 350 CFM · Vrf Indoor ×2 MXZ-SM60NAM2 66,000 BTU · Condensing Unit ×1 PEFY-P30NMAU 875 CFM · Vrf Indoor ×1 PFFY-P08NRMU 229 CFM · Vrf Indoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/21/2024 | Signed-off | A.M.N. CORPORATION | Gas, Water/Sanitary |
| 08/01/2023 | — | — | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/16/2024 | Complete | DENMAR ELECTRIC CORP | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/21/2024 | Signed-off | J.K. REMODELING INC | Steel |
| Date | Type | Result | Report |
|---|---|---|---|
| 10/10/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 10/02/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/17/2024 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 05/06/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/21/2024 | Maintenance information | MOLLY GLENN | energy_progress |
| 10/21/2024 | HVAC-R and service water piping design and insulation | MOLLY GLENN | energy_progress |
| 10/18/2024 | Maintenance information | MOLLY GLENN | energy_progress |
| 10/18/2024 | HVAC-R and service water piping design and insulation | MOLLY GLENN | energy_progress |
| 06/27/2024 | Fenestration and door U-factor and product ratings | Josh Heitler | energy_progress |
| 06/27/2024 | Fenestration areas | Josh Heitler | energy_progress |
| 06/27/2024 | Final | Josh Heitler | progress |
| 06/27/2024 | Insulation placement and R values | Josh Heitler | energy_progress |
| 06/27/2024 | Metering | Josh Heitler | energy_progress |
| 06/27/2024 | Fenestration air leakage | Josh Heitler | energy_progress |
| 06/27/2024 | Fire-Resistant Penetrations and Joints | MOLLY GLENN | special |
| 06/27/2024 | Fire-Resistance Rated Construction | Josh Heitler | progress |
| 06/27/2024 | Lighting in dwelling units | Josh Heitler | energy_progress |
| 06/14/2024 | Fenestration and door U-factor and product ratings | Josh Heitler | energy_progress |
| 06/14/2024 | HVAC-R and service water piping design and insulation | MOLLY GLENN | energy_progress |
| 06/14/2024 | Maintenance information | MOLLY GLENN | energy_progress |
| 06/14/2024 | Fire-Resistant Penetrations and Joints | MOLLY GLENN | special |
| 06/14/2024 | Final | Josh Heitler | progress |
| 06/14/2024 | Fire-Resistance Rated Construction | Josh Heitler | progress |
| 06/14/2024 | Insulation placement and R values | Josh Heitler | energy_progress |
| 06/14/2024 | Lighting in dwelling units | Josh Heitler | energy_progress |
| 06/14/2024 | Metering | Josh Heitler | energy_progress |
| 06/14/2024 | Fenestration air leakage | Josh Heitler | energy_progress |
| 06/14/2024 | Fenestration areas | Josh Heitler | energy_progress |
| 02/29/2024 | Structural Stability – Alterations of existing buildings | Erik Madsen | special |