← Back
Mansion type or town house
125 EAST 65 STREET
MANHATTAN · Upper East Side-Carnegie Hill · BIN 1042421
💬 Discuss this project
1905Year Built
4Stories
A7Building Class
R8BZoning
11,989 sfGross Floor Area
1Units
1 Open Violation ▸
Mansion type or town house · Owner of record: 125 EAST 65TH OWNER LLC · 3,515 sf lot · 3.41 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneral
Roof18p · 2 filings · 10 docs
Floor 514p · 3 filings · 12 docs
Floor 430p · 4 filings · 20 docs
Floor 331p · 4 filings · 20 docs
Floor 231p · 4 filings · 20 docs
Floor 132p · 4 filings · 20 docs
Cellar27p · 3 filings · 18 docs
Sub-Basement15p · 2 filings · 13 docs
Site & exterior14p · 3 filings · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BNYD & C1303/22/2026
CF EAST 72 OWNER707/08/2026
OWNERS REP503/22/2026
125 EAST 65TH STREET503/21/2026
I G GROUP407/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/18/2021$14.9M—125 EAST 65TH STREET INC. → 125 EAST 65TH OWNER LLC$1,243/sf building
09/17/2014$22.0M—— → —$1,835/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PAUL PERDEK, PROF. ENG. PLLC211/14/2023
CONCESSI ENGINEERING, P.C.210/11/2023
BILD ARCHITECTURE110/04/2022
C3D ARCHITECTURE PLLC101/31/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PWF203/21/2026
YBL NY403/21/2026
AE DESIGN SOLUTION403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CORE SCAFFOLD SYSTEMS INC.General Contractor603/21/2026
I & G GROUP, INCGeneral Contractor607/08/2026
AMK MECHANICAL LTDGeneral Contractor303/21/2026
INNOVATIVE HEATING SOLUTIPlumbing207/08/2026
JULIAN SPRINKLER CORPFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CONCESSI ENGINEERING, P.C540210/11/2023
Building Lifecycle
All (41)Filed (6)Permit Issued (10)Signed Off (3)Violation (17)Inspection (5)
11/22/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/22/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/22/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/12/2024
Permit issued — Plumbing
M00936244-S1-PL
04/12/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/09/2024
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00961081-I1
04/09/2024
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00961082-I1
02/06/2024
Violation issued (ECB, closed)
Construction
02/05/2024
Violation issued (ECB, closed)
Construction
01/26/2024
Permit issued — General Construction
M08002060-I1-GC
11/16/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/15/2023
Permit issued — Sidewalk Shed
M00961081-I1-SH
11/14/2023
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00961081-I1
11/14/2023
Permit issued — Supported Scaffold
M00961082-I1-SF
11/13/2023
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00961082-I1
10/31/2023
Permit issued — Plumbing
M00936244-S1-EW-SP
10/24/2023
Permit issued — General Construction
M08002060-I1-GC
10/13/2023
Permit issued — Plumbing
M00936244-S1-PL
10/11/2023
Filed — Alteration
Install new HVAC system for 4-story building, no change in use, egress and occupancy.
M00936244-S1
10/11/2023
Filed — Alteration
Install new HVAC system for 4-story building, no change in use, egress and occupancy.
M00936244-I1
10/11/2023
Permit issued — Mechanical Systems
M00936244-I1-MS
10/10/2022
Permit issued — General Construction
M08002060-I1-GC
10/04/2022
Filed — Alteration
Installing of new partitions walls, new elevator, new stair, new kitchen, bathroom, interior doors, sauna/steam room and flooring. No change in use, occupancy or egress.
M08002060-I1
05/27/2022
Signed off — Alteration
Interior demo of partitions. No change to use egress or occupancy.
M00669083-I1
02/04/2022
Permit issued — General Construction
M00669083-I1-GC
01/31/2022
Filed — Alteration
Interior demo of partitions. No change to use egress or occupancy.
M00669083-I1
06/22/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/05/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/05/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/08/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/28/2009
Violation issued (ECB, closed)
Boilers
08/15/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/05/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/26/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/23/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/20/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/13/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/13/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/14/1996
Violation issued (ECB, closed)
Elevators
11/04/1988
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedMITIE PLUMBING & HTG CORP11/12/2024
DOB NOWGeneral ConstructionPermit IssuedI & G GROUP, INC01/26/2024
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC11/15/2023
DOB NOWSupported ScaffoldSigned-offCORE SCAFFOLD SYSTEMS INC11/14/2023
DOB NOWPlumbingPermit IssuedJULIAN PLBG & HTG CORP10/31/2023
DOB NOWGeneral ConstructionPermit IssuedI & G GROUP, INC10/24/2023
DOB NOWPlumbingPermit IssuedMITIE PLUMBING & HTG CORP10/13/2023
DOB NOWMechanical SystemsPermit IssuedAMK MECHANICAL LTD10/11/2023
DOB NOWGeneral ConstructionPermit IssuedI & G GROUP, INC10/10/2022
DOB NOWGeneral ConstructionSigned-offI & G GROUP, INC02/04/2022
BIS—ISSUEDIHOME IMPROVEMENT & WINDO03/04/2016
BISPLISSUEDRRP PLUMBING CORP10/07/2015
BIS—ISSUEDLI TAN CONSTRUCTION CORP09/30/2015
BISMHISSUEDS & W WILSON ENTERPRISES08/06/1998
1 project · most recent 10/11/2023
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/11/2023Permit IssuedAMK MECHANICAL LTDAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Daikin REYQ360TTJU 35 tons · Vrf Outdoor ×1
Heating
Daikin REYQ360TTJU 360,000 BTU · Vrf Outdoor ×1
Ventilation
Fantech DBF4XLT 170 CFM · Exhaust Fan ×1
Greenheck CUBE-160 1,200 CFM · Kitchen Exhaust ×1
5 projects · most recent 03/26/2025
General Wiring Lighting
FiledStatusContractorScope
03/26/2025Permit IssuedECO ELECTRICAL SERVCS LLCGeneral Wiring, Lighting
03/26/2025Permit IssuedECO ELECTRICAL SERVCS LLC—
11/13/2023CompleteSOLAS ELECTRICAL CORP—
11/10/2023Permit IssuedJAM ELECTRICAL CORP—
08/22/2023Permit IssuedLND ELECTRIC LLCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
11/22/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/22/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/22/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
04/12/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/16/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
01/26/2022FinalDamir Sehicprogress
▾Documents — 77 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
09/02/2026M00669083-I1Request digital key ↗
09/01/2026M08002060-I1Request digital key ↗
08/29/2026M00936244-S1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits15
▸BISPLAN / WORK APPROVAL APPLICATION6
05/04/2016122382215Open ↗
01/27/2016122382215Open ↗
12/16/2015122382215Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION4
03/28/2016122382215Open ↗
10/23/2015122382215Open ↗
10/23/2015122382215Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLPC Approval/Permit4
08/13/2026M08002060-I1Open ↗
08/13/2026M00936244-S1Open ↗
08/13/2026M00669083-I1Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
01/13/2016122382215Open ↗
▸Seals & Professional Certifications14
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION7
08/09/2017122382215Open ↗
02/12/2016122382215Open ↗
07/16/2015122382215Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/28/2026M00961082-I1Open ↗
08/13/2026M08002060-I1Open ↗
08/13/2026M00961081-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
09/02/2026M00669083-I1Open ↗
▸Trade Schedules & Equipment6
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE4
01/27/2016122382215Open ↗
12/16/2015122382215Open ↗
04/30/2015122382215Open ↗
Showing 3 of 4 on file for this type
▸BISEQUIPMENT USE PERMITS1
08/09/2017122382215Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
09/15/2015122382215Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST2
07/17/2015122382215Open ↗
04/30/2015122382215Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026M08002060-I1Open ↗
08/13/2026M00936244-I1Open ↗
08/13/2026M00936244-S1Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
10/07/2015122382215Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/13/2026M00669083-I1Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
04/30/2015122382215Open ↗
▸Inspections & Test Reports2
▸BISHYDRAULIC FLOW CALCULATIONS1
07/16/2015122382215Open ↗
▸BISHYDRO FLOW TEST LETTER1
07/16/2015122382215Open ↗
▸Approvals, Objections & Sign-offs8
▸BISLETTERS - SUPPORTING DOCUMENTATION2
08/09/2017122382215Open ↗
08/09/2017122382215Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE2
07/16/2015122382215Open ↗
04/30/2015122382215Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
08/09/2017122382215Open ↗
05/22/2017122382215Open ↗
▸BISSUPERSEDING LETTER1
03/28/2016122382215Open ↗
▸BISLANDMARKS SIGNOFF1
08/09/2017122382215Open ↗
▸Cost, Insurance & Ownership7
▸BISCOST AFFIDAVIT7
08/09/2017122382215Open ↗
08/09/2017122382215Open ↗
05/22/2017122382215Open ↗
Showing 3 of 7 on file for this type
▸Filing & Intake Forms8
▸BISADDITIONAL INFORMATION6
08/09/2017122382215Open ↗
03/07/2016122382215Open ↗
01/27/2016122382215Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING COVER SHEET2
04/30/2015122382215Open ↗
04/30/2015122382215Open ↗
▸Other Documents3
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
07/16/2015122382215Open ↗
▸BISPLOT DIAGRAM1
04/30/2015122382215Open ↗
▸DOB NOWProof of Historic Building1
08/13/2026M08002060-I1Open ↗