← Back
Primarily 2 family with 1 store or office
1250 FLATBUSH AVENUE
BROOKLYN · BIN 3120301
💬 Discuss this project
1933Year Built
3Stories
S2Building Class
R7AZoning
3,300 sfGross Floor Area
3Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: 1250 FLATBUSH LLC · 1,485 sf lot · 2.22 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Roof1p · 1 filing · 12 docs
Floor 21p · 1 filing · 5 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PARKVIEW MANAGEMENT GROUP607/08/2026
KYUNG SUE CHUNG (PROPERTY103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/15/2020$995K—— → —$302/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
L & C ASSOCIATES301/17/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
L&C ASSOCIATES303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J S REMODELING NY INCGeneral Contractor107/08/2026
EH PLUMBING & HEATING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LAM AND CO CONSULTING LLC8065201/17/2023
Building Lifecycle
All (29)Filed (3)Permit Issued (2)Signed Off (2)Violation (22)
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/16/2023
Signed off — Alteration
PLUMBING WORK. AS PER PLANS. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION
B08018750-I1
01/24/2023
Signed off — Alteration
INTERIOR RENOVATION WITH PARTITIONS. AS PER PLAN. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION.
B08018729-I1
01/17/2023
Filed — Alteration
INTERIOR RENOVATION WITH PARTITIONS. AS PER PLAN. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION.
B08018729-P1
11/21/2022
Permit issued — Plumbing
B08018750-I1-PL
11/04/2022
Permit issued — General Construction
B08018729-I1-GC
10/25/2022
Filed — Alteration
PLUMBING WORK. AS PER PLANS. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION
B08018750-I1
10/25/2022
Filed — Alteration
INTERIOR RENOVATION WITH PARTITIONS. AS PER PLAN. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION.
B08018729-I1
02/12/2022
Violation issued (HPD, closed)
B
02/12/2022
Violation issued (HPD, closed)
B
02/12/2022
Violation issued (HPD, closed)
B
02/12/2022
Violation issued (HPD, closed)
B
02/12/2022
Violation issued (HPD, closed)
B
02/12/2022
Violation issued (HPD, closed)
A
02/12/2022
Violation issued (HPD, closed)
B
02/12/2022
Violation issued (HPD, closed)
B
02/12/2022
Violation issued (HPD, closed)
B
02/12/2022
Violation issued (HPD, closed)
B
12/20/2021
Violation issued (HPD, closed)
C
06/22/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/23/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/05/2005
Violation issued (ECB, closed)
Boilers
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/17/1992
Violation issued (ECB, closed)
Boilers
11/18/1992
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offEH PLUMBING & HEATING COR11/21/2022
DOB NOWGeneral ConstructionSigned-offJ S REMODELING NY INC11/04/2022
BISBLISSUEDS.J. FUEL CO., INC12/09/1997
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
01/27/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/23/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/20/2023Pass-Final General Construction Non-Directive 14PassView ↗
01/09/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
12/16/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/16/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
01/18/2023Fire-Resistant Penetrations and JointsCHI WAI CHUNGspecial
01/18/2023Interior lighting powerCHI WAI CHUNGenergy_progress
01/18/2023Energy Code Compliance InspectionsCHI WAI CHUNGprogress
01/17/2023Energy Code Compliance InspectionsCHI WAI CHUNGprogress
01/17/2023Fire-Resistant Penetrations and JointsCHI WAI CHUNGspecial
01/17/2023Interior lighting powerCHI WAI CHUNGenergy_progress
10/14/2022HVAC-R and service water heating equipmentCHI WAI CHUNGenergy_progress
10/14/2022HVAC-R and service water piping design and insulationCHI WAI CHUNGenergy_progress
10/14/2022HVAC-R and service water heating system controlsCHI WAI CHUNGenergy_progress
10/14/2022Energy Code Compliance InspectionsCHI WAI CHUNGprogress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/28/2026B08018750-I1Request digital key ↗
08/27/2026B08018729-I1Request digital key ↗
08/27/2026B08018729-P1Request digital key ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B08018729-I1Open ↗
09/01/2026B08018729-I1Open ↗
08/25/2026B08018729-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/28/2026B08018750-I1Open ↗
08/27/2026B08018729-I1Open ↗
08/13/2026B08018729-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B08018729-I1Open ↗
08/25/2026B08018729-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/28/2026B08018750-I1Open ↗
08/27/2026B08018729-I1Open ↗
08/13/2026B08018729-P1Open ↗