← Back
Two family frame
1259 RICHMOND AVENUE
STATEN ISLAND · BIN 5029916
💬 Discuss this project
1901Year Built
2.5Stories
B2Building Class
R3XZoning
2,952 sfGross Floor Area
2Units
Two family frame · Owner of record: HIPO HOLDINGS LLC · 5,998 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
JARNS HOLDING INC903/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FANG ARCHITECT302/22/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JAYA CONTRACTING INCGeneral Contractor303/21/2026
SMART PLBG & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FANG ARCHITECT5513302/22/2023
Building Lifecycle
All (22)Filed (3)Permit Issued (2)Signed Off (2)Inspection (3)Special Inspection (12)
03/13/2023
Signed off — Alteration
S00773701-I1
03/13/2023
Signed off — Alteration
INTERIOR RENOVATION FOR EXISTING 2-FAMILY HOUSE. NO CHANGE TO EXIST. USE & OCCUPANCY.
S00773688-I1
03/10/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
02/22/2023
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING 2-FAMILY HOUSE. NO CHANGE TO EXIST. USE & OCCUPANCY.
S00773688-P1
02/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
DEZHANG FANG
02/22/2023
Special inspection requirement — Energy Code Compliance Inspections
DEZHANG FANG
02/22/2023
Special inspection requirement — Fire-Resistance Rated Construction
DEZHANG FANG
02/22/2023
Special inspection requirement — Insulation placement and R values
DEZHANG FANG
02/22/2023
Special inspection requirement — Fenestration areas
DEZHANG FANG
02/22/2023
Special inspection requirement — Fenestration air leakage
DEZHANG FANG
02/22/2023
Special inspection requirement — HVAC-R and service water heating equipment
DEZHANG FANG
02/22/2023
Special inspection requirement — HVAC-R and service water heating system controls
DEZHANG FANG
02/22/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
DEZHANG FANG
02/22/2023
Special inspection requirement — Interior lighting power
DEZHANG FANG
02/22/2023
Special inspection requirement — Maintenance information
DEZHANG FANG
02/22/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
DEZHANG FANG
10/20/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/20/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/20/2022
Permit issued — Plumbing
S00773701-I1-PL
09/19/2022
Permit issued — General Construction
S00773688-I1-GC
07/28/2022
Filed — Alteration
S00773701-I1
07/28/2022
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING 2-FAMILY HOUSE. NO CHANGE TO EXIST. USE & OCCUPANCY.
S00773688-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offSMART PLBG & HTG CORP09/20/2022
DOB NOWGeneral ConstructionSigned-offJAYA CONTRACTING INC09/19/2022
1 project · most recent 09/26/2022
General Wiring
FiledStatusContractorScope
09/26/2022CompleteINTELOGIC ELECTRIC, INC.General Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
03/10/2023Pass-Final General Construction Non-Directive 14PassView ↗
10/20/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/20/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
02/22/2023Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
02/22/2023Energy Code Compliance InspectionsDEZHANG FANGprogress
02/22/2023Fire-Resistance Rated ConstructionDEZHANG FANGprogress
02/22/2023Insulation placement and R valuesDEZHANG FANGenergy_progress
02/22/2023Fenestration areasDEZHANG FANGenergy_progress
02/22/2023Fenestration air leakageDEZHANG FANGenergy_progress
02/22/2023HVAC-R and service water heating equipmentDEZHANG FANGenergy_progress
02/22/2023HVAC-R and service water heating system controlsDEZHANG FANGenergy_progress
02/22/2023Fenestration and door U-factor and product ratingsDEZHANG FANGenergy_progress
02/22/2023Interior lighting powerDEZHANG FANGenergy_progress
02/22/2023Maintenance informationDEZHANG FANGenergy_progress
02/22/2023HVAC-R and service water piping design and insulationDEZHANG FANGenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026S00773701-I1Request digital key ↗
08/23/2026S00773688-P1Request digital key ↗
08/23/2026S00773688-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026S00773701-I1Open ↗
08/23/2026S00773688-I1Open ↗
08/13/2026S00773688-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026S00773688-P1Open ↗
08/25/2026S00773688-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026S00773688-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/23/2026S00773688-I1Open ↗
08/13/2026S00773688-P1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026S00773688-I1Open ↗