← Back
Elevator apt, semi-fireproof with stores
The 128 Hester Street Condominium
126 HESTER STREET · BIN 1091754
💬 Discuss this project
2024Year Built
7Stories
D7Building Class
C6-1GZoning
14,440 sfGross Floor Area
9Units
0 Open Violations
Elevator apt, semi-fireproof with stores · Owner of record: FORTUNE ASSETS LLC · 2,493 sf lot · 5.79 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Roof68p · 1 filing · 20 docs
Floor 764p · 1 filing · 20 docs
Floor 667p · 1 filing · 20 docs
Floor 567p · 1 filing · 20 docs
Floor 470p · 1 filing · 20 docs
Floor 366p · 1 filing · 20 docs
Floor 265p · 1 filing · 20 docs
Floor 169p · 1 filing · 20 docs
Cellar68p · 1 filing · 20 docs
1 job · most recent 08/05/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/05/2025Permit IssuedPRO-H DEVELOPMENT INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM36NAM2-U1 36,000 BTU · Heat Pump Outdoor ×13
PEFY-P36NMAU-E4 40,000 BTU · Vrf Indoor ×6
PEFY-P30NMAU-E4 340,000 BTU · Vrf Indoor ×4
PEFY-P18NMAU-E4 36,000 BTU · Vrf Indoor ×3
PLFY-P18NFMU-E 20,000 BTU · Vrf Indoor ×2
MSZ-GS24NA 21,200 BTU · Split System ×1
MUZ-GS24NAHZ 22,400 BTU · Heat Pump Outdoor ×1
MXZ-SM60NAM2-U1 60,000 BTU · Heat Pump Outdoor ×1
PEFY-P15NMAU-E4 17,000 BTU · Vrf Indoor ×1
Renewaire HE10-JRTH-S11AA---GNT---L 590 CFM · Erv ×1
Ventilation
Greenheck G-097-VG 1 BTU · Exhaust Fan ×4
G-080-VG 1 BTU · Exhaust Fan ×1
G-095-VG 17,000 BTU · Exhaust Fan ×1
SQ-120-VG 1 BTU · Exhaust Fan ×1
Renewaire HE07-JINH-S11AA---GNT---L 300 BTU · Erv ×1
1 job · most recent 08/05/2025
Sprinkler System
FiledStatusContractorScope
08/05/2025Signed-offRRP PLUMBING CORPSprinkler System
1 job · most recent 08/05/2025
Storm Water/Sanitary
FiledStatusContractorScope
08/05/2025Signed-offRRP PLUMBING CORPStorm, Water/Sanitary
8 jobs · most recent 04/15/2026
General Wiring Boiler Controls
FiledStatusContractorScope
04/15/2026CompleteE D ELECTRICAL INCGeneral Wiring
04/15/2026CompleteE D ELECTRICAL INCBoiler Controls
04/15/2026CompleteE D ELECTRICAL INC—
04/15/2026CompleteE D ELECTRICAL INC—
10/23/2025CompleteINTELOGIC ELECTRIC, INC.General Wiring
09/06/2025CompleteE D ELECTRICAL INCGeneral Wiring
06/10/2024CompleteBOROWIDE ELECT'L CONTR'S—
06/12/2023CompleteE D ELECTRICAL INC—
1 job · most recent 08/05/2025
Concrete
FiledStatusContractorScope
08/05/2025Signed-offRRP PLUMBING CORPConcrete
1 job · most recent 08/05/2025
Fence
FiledStatusContractorScope
08/05/2025Signed-offRRP PLUMBING CORPFence
Building Lifecycle
All (171)Filed (24)Permit Issued (30)Signed Off (6)Violation (60)Inspection (9)Objection (12)Special Inspection (30)
04/17/2026
Inspection — Certified StandPipe - SD - Alarm Sys 64/09 - Finish
Certified
View inspection ↗
04/17/2026
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
11/26/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/20/2025
Permit issued — Plumbing
M00701234-S4-PL
10/06/2025
Inspection — Certified Sprinkler (SP) - Booster Pump Test
Certified
View inspection ↗
10/02/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/23/2025
Signed off — Alteration
M08012798-I1
09/22/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/15/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/22/2025
Special inspection requirement — Lighting controls
GLEN LANGER
08/22/2025
Special inspection requirement — Lighting in dwelling units
GLEN LANGER
08/22/2025
Special inspection requirement — Maintenance information
GLEN LANGER
08/22/2025
Special inspection requirement — Metering
GLEN LANGER
08/22/2025
Special inspection requirement — Fenestration air leakage
GLEN LANGER
08/22/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
GLEN LANGER
08/22/2025
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
GLEN LANGER
08/22/2025
Special inspection requirement — Air barrier - visual inspection
GLEN LANGER
08/22/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
08/22/2025
Special inspection requirement — Fire-Resistance Rated Construction
GLEN LANGER
08/22/2025
Special inspection requirement — Fenestration areas
GLEN LANGER
08/22/2025
Special inspection requirement — Insulation placement and R values
GLEN LANGER
08/22/2025
Special inspection requirement — Electrical motors and elevators
GLEN LANGER
08/22/2025
Special inspection requirement — Exterior lighting power
GLEN LANGER
08/22/2025
Special inspection requirement — Interior lighting power
GLEN LANGER
08/22/2025
Special inspection requirement — Air barrier — testing
GLEN LANGER
08/22/2025
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
08/22/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
GLEN LANGER
08/21/2025
Signed off — New Building
Construct new 7 story mixed-use building as per plans filed.
M00701234-S7
08/05/2025
Filed — New Building
Construct new 7 story mixed-use building as per plans filed.
M00701234-A5
07/24/2025
Special inspection requirement — Metering
GLEN LANGER
07/24/2025
Special inspection requirement — Air barrier — testing
GLEN LANGER
07/24/2025
Special inspection requirement — Exterior lighting power
GLEN LANGER
07/24/2025
Special inspection requirement — Lighting in dwelling units
GLEN LANGER
07/24/2025
Special inspection requirement — Fenestration air leakage
GLEN LANGER
07/24/2025
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
GLEN LANGER
07/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
07/24/2025
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
07/24/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
GLEN LANGER
07/24/2025
Special inspection requirement — Fire-Resistance Rated Construction
GLEN LANGER
07/24/2025
Special inspection requirement — Interior lighting power
GLEN LANGER
07/24/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
GLEN LANGER
07/14/2025
Permit issued — General Construction
M00701234-I1-GC
07/03/2025
Filed — New Building
Construct new 7 story mixed-use building as per plans filed.
M00701234-A4
06/10/2025
Signed off — Alteration
M00935665-I1
05/19/2025
Permit issued — Construction Fence
M00701234-S7-FN
05/14/2025
Objection resolved — Addressed
05/13/2025
Objection raised — Admin
05/02/2025
Filed — New Building
Construct new 7 story mixed-use building as per plans filed.
M00701234-A3
04/10/2025
Signed off — Alteration
PROPOSED INSTALLATION OF TEMPORARY LIGHT DUTY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M00935666-I1
03/18/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
03/04/2025
Filed — New Building
Construct new 7 story mixed-use building as per plans filed.
M00701234-P8
02/26/2025
Objection resolved — Addressed
02/13/2025
Violation issued (ECB, closed)
Construction
02/05/2025
Objection raised — Energy
01/22/2025
Filed — New Building
Construct new 7 story mixed-use building as per plans filed.
M00701234-P7
12/24/2024
Violation issued (ECB, closed)
Construction
12/02/2024
Signed off — Alteration
FACADE RESTORATION VIA SUSPENDED SCAFFOLDING
M01118325-I1
11/19/2024
Signed off — New Building
Construct new 7 story mixed-use building as per plans filed.
M00701234-S1
11/01/2024
Permit issued — Suspended Scaffold
M01118325-P1-SC
10/22/2024
Filed — Alteration
FACADE RESTORATION VIA SUSPENDED SCAFFOLDING
M01118325-P1
Latest 60 of 171 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FORTUNE ASSETS8407/08/2026
PRO-H DEVELOPMENT2607/08/2026
MING DAX CONSTRUCTION103/22/2026
LEE PAN REALTY2503/22/2026
128 HESTER2603/22/2026
CALABRESE ASSOCIATES203/22/2026
MANHATTAN DEMOLITION CO203/22/2026
128 HESTER LLC OWNER103/22/2026
LEE PAN REALTY CORP OWNER103/22/2026
SIMON WONG 128 HOSTER LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/27/2018$3.8M—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.1903/21/2026
MODERN BUILDING CONSULTANT103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRO-H DEVELOPMENT INCGeneral Contractor2207/08/2026
ANDAMIO SCAFFOLDING LLCGeneral Contractor807/08/2026
RRP PLUMBING CORPPlumbing207/08/2026
ISAAKIDES, HERCULESElectrical103/21/2026
JEONG YUNGElectrical103/21/2026
LAMBERT, LESLIEElectrical103/21/2026
NICHOLAS ROSELLAElectrical103/21/2026
STANLEY MURRAY PLBG & HTGElectrical103/21/2026
ASHLEY, ANTHONYElectrical103/21/2026
JEM FIRE PREVENTION INCFire Protection107/08/2026
RRP PLUMBING CORPFire Protection107/08/2026
JZ CONSTRUCTION GROUP INCGeneral Contractor107/08/2026
PIPESTYLISTS, INCPlumbing107/08/2026
STEWART, DUDLEYElectrical103/21/2026
BOROWIDE ELECT'L CONTR'SElectrical103/22/2026
INTELOGIC ELECTRIC, INC.Electrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
S&S CONCRETE & SOIL TESTI10081608/05/2025
PCS ENGINEERING3745210/22/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offRRP PLUMBING CORP10/20/2025
DOB NOWGeneral ConstructionPermit IssuedPRO-H DEVELOPMENT INC07/14/2025
DOB NOWConstruction FenceSigned-offPRO-H DEVELOPMENT INC05/19/2025
DOB NOWSuspended ScaffoldPermit IssuedRIGGING CONSULTANTS INC11/01/2024
DOB NOWMechanical SystemsSigned-offPRO-H DEVELOPMENT INC10/18/2024
DOB NOWSuspended ScaffoldSigned-offRIGGING CONSULTANTS INC10/07/2024
DOB NOWSprinklersSigned-offRALPH W. LANDOLFI JR.09/24/2024
DOB NOWPlumbingSigned-offRRP PLUMBING CORP09/24/2024
DOB NOWSupported ScaffoldSigned-offANDAMIO SCAFFOLDING LLC09/16/2024
DOB NOWSidewalk ShedSigned-offANDAMIO SCAFFOLDING LLC09/16/2024
DOB NOWGeneral ConstructionPermit IssuedPRO-H DEVELOPMENT INC09/05/2024
DOB NOWStructuralSigned-offPRO-H DEVELOPMENT INC09/05/2024
DOB NOWGeneral ConstructionPermit IssuedPRO-H DEVELOPMENT INC08/30/2024
DOB NOWStructuralSigned-offPRO-H DEVELOPMENT INC08/30/2024
DOB NOWConstruction FenceSigned-offPRO-H DEVELOPMENT INC06/04/2024
DOB NOWSupport of ExcavationSigned-offPRO-H DEVELOPMENT INC05/23/2024
DOB NOWGeneral ConstructionPermit IssuedPRO-H DEVELOPMENT INC05/23/2024
DOB NOWStructuralSigned-offPRO-H DEVELOPMENT INC05/23/2024
DOB NOWFoundationSigned-offPRO-H DEVELOPMENT INC05/22/2024
DOB NOWStructuralSigned-offPRO-H DEVELOPMENT INC10/26/2023
DOB NOWMechanical SystemsSigned-offPRO-H DEVELOPMENT INC10/05/2023
DOB NOWSprinklersSigned-offJEM FIRE PREVENTION INC09/27/2023
DOB NOWPlumbingSigned-offT & T PLUMBING INC09/25/2023
DOB NOWSupported ScaffoldSigned-offANDAMIO SCAFFOLDING LLC09/19/2023
DOB NOWSidewalk ShedSigned-offANDAMIO SCAFFOLDING LLC09/19/2023
DOB NOWConstruction FenceSigned-offPRO-H DEVELOPMENT INC06/26/2023
DOB NOWSupport of ExcavationSigned-offPRO-H DEVELOPMENT INC06/24/2023
DOB NOWGeneral ConstructionPermit IssuedPRO-H DEVELOPMENT INC06/23/2023
DOB NOWFoundationSigned-offPRO-H DEVELOPMENT INC06/23/2023
DOB NOWConstruction FenceSigned-offJZ CONSTRUCTION GROUP INC12/15/2022
BISOTISSUEDMANHATTAN DEMOLITION CO INC02/24/2010
BISEQISSUEDMANHATTAN DEMOLITION CO I01/15/2010
BIS—ISSUEDMANHATTAN DEMOLITION CO I01/15/2010
BIS—ISSUEDMANHATTAN DEMO CO INC09/25/2009
BISEQISSUEDM.S.S. CONSTRUCTION CORP07/21/2009
BISEQISSUEDM.S.S. CONSTRUCTION CORP04/28/2009
BISEQISSUEDMING DAX CONSTRUCTION INC04/09/2008
BIS—ISSUEDMING DAX CONSTRUCTION INC.04/09/2008
BIS—ISSUEDMING DAX CONSTRUCTION INC.02/01/2008
BISEQISSUEDMING DAX CONSTRUCTION INC01/25/2008
+ 14 more permits on file
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
04/17/2026Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
04/17/2026Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
11/26/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/06/2025Certified Sprinkler (SP) - Booster Pump TestCertifiedView ↗
10/02/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/22/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/15/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
03/18/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
11/17/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 124
DateRequirementInspectorRole
08/22/2025Fire-Resistance Rated ConstructionGLEN LANGERprogress
08/22/2025Energy Code Compliance InspectionsGLEN LANGERprogress
08/22/2025Mastic and Intumescent Fire-resistant CoatingsGLEN LANGERspecial
08/22/2025Exterior Insulation and Finish Systems (EIFS)GLEN LANGERspecial
08/22/2025Fire-Resistant Penetrations and JointsGLEN LANGERspecial
08/22/2025Lighting in dwelling unitsGLEN LANGERenergy_progress
08/22/2025Maintenance informationGLEN LANGERenergy_progress
08/22/2025Air barrier - visual inspectionGLEN LANGERenergy_progress
08/22/2025Electrical motors and elevatorsGLEN LANGERenergy_progress
08/22/2025Exterior lighting powerGLEN LANGERenergy_progress
08/22/2025Fenestration and door U-factor and product ratingsGLEN LANGERenergy_progress
08/22/2025Fenestration areasGLEN LANGERenergy_progress
08/22/2025Insulation placement and R valuesGLEN LANGERenergy_progress
08/22/2025Interior lighting powerGLEN LANGERenergy_progress
08/22/2025MeteringGLEN LANGERenergy_progress
08/22/2025Lighting controlsGLEN LANGERenergy_progress
08/22/2025Fenestration air leakageGLEN LANGERenergy_progress
08/22/2025Air barrier — testing GLEN LANGERenergy_progress
07/24/2025Air barrier - visual inspectionGLEN LANGERenergy_progress
07/24/2025Fire-Resistance Rated ConstructionGLEN LANGERprogress
07/24/2025Energy Code Compliance InspectionsGLEN LANGERprogress
07/24/2025Mastic and Intumescent Fire-resistant CoatingsGLEN LANGERspecial
07/24/2025Fire-Resistant Penetrations and JointsGLEN LANGERspecial
07/24/2025Exterior Insulation and Finish Systems (EIFS)GLEN LANGERspecial
07/24/2025Lighting in dwelling unitsGLEN LANGERenergy_progress
Latest 25 of 124.
▾Documents — 218 on file (BIS + DOB NOW)
▸Plans & Drawings24
▸DOB NOWPlans/Sketch24
09/01/2026M08012798-I1Request digital key ↗
08/29/2026M00935666-I1Request digital key ↗
08/29/2026M00935665-I1Request digital key ↗
Showing 3 of 24 on file for this type
▸Applications & Permits20
▸BISPLAN / WORK APPROVAL APPLICATION12
01/23/2026104526461Open ↗
01/23/2026103938740Open ↗
12/09/2025104252951Open ↗
Showing 3 of 12 on file for this type
▸BISWORK PERMIT APPLICATION8
02/25/2010120264123Open ↗
01/16/2010120146724Open ↗
01/16/2010120146724Open ↗
Showing 3 of 8 on file for this type
▸Zoning, Tax Lot & Property Records12
▸DOB NOWZD1: DOB Zoning Diagram4
08/13/2026M00701234-P6Open ↗
08/13/2026M00701234-P8Open ↗
08/13/2026M00701234-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZoning Exhibit form (1-5)4
08/13/2026M00701234-A5Open ↗
08/13/2026M00701234-P6Open ↗
08/13/2026M00701234-P8Open ↗
Showing 3 of 4 on file for this type
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED2
11/19/2025121254230Open ↗
04/26/2022141008488Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
11/19/2025121254230Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026M00701234-I1Open ↗
▸Seals & Professional Certifications82
▸DOB NOWDPL-1: Design Professional Seal & Signature22
09/01/2026M08012798-I1Open ↗
08/29/2026M00935665-I1Open ↗
08/23/2026M00701234-S7Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature20
09/15/2026M00701234-S3Open ↗
09/01/2026M00701234-A4Open ↗
08/31/2026M00701234-P3Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWProgress Inspector Seal & Signature18
09/15/2026M00701234-S3Open ↗
09/01/2026M00701234-A4Open ↗
09/01/2026M00701234-A4Open ↗
Showing 3 of 18 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
03/03/2010120264123Open ↗
02/11/2010120264123Open ↗
02/11/2010120264123Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
02/11/2010120264123Open ↗
10/19/2009120181686Open ↗
07/22/2009120112038Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM4
02/11/2010120264123Open ↗
10/19/2009120181686Open ↗
07/22/2009120112038Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
04/26/2022141008488Open ↗
03/12/2014140170543Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
03/12/2014140170543Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/12/2014140170543Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
04/26/2022141008488Open ↗
▸Trade Schedules & Equipment7
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)4
08/13/2026M00701234-I1Open ↗
08/13/2026M00701234-P8Open ↗
08/13/2026M00701234-P6Open ↗
Showing 3 of 4 on file for this type
▸BISELECTRIC CUT-OFF1
09/28/2009120146724Open ↗
▸BISWATER METER PERMIT : DEP-METER1
09/28/2009120146724Open ↗
▸BISSEWER CONNECTION: DEP SD1 & SD21
09/28/2009120146724Open ↗
▸Safety & Tenant Protection9
▸DOB NOWStreet Tree Checklist4
08/13/2026M00701234-A5Open ↗
08/13/2026M00701234-P8Open ↗
08/13/2026M00701234-P6Open ↗
Showing 3 of 4 on file for this type
▸BISBPP: STREET TREES SITE PLAN1
04/26/2022141008488Open ↗
▸BISSTREET TREE CHECKLIST1
02/11/2010120264123Open ↗
▸BISST-1 Street Tree Checklist1
10/19/2009120181686Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026M00701234-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026M00701234-I1Open ↗
▸Environmental & Asbestos6
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER4
02/11/2010120264123Open ↗
10/19/2009120181686Open ↗
07/22/2009120112038Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
09/02/2009120146724Open ↗
▸BISRODENT CONTROL1
09/28/2009120146724Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
04/26/2022141008488Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/23/2026M00701234-S6Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026M00701234-I1Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
03/12/2014140170543Open ↗
▸Approvals, Objections & Sign-offs13
▸BISLETTERS - SUPPORTING DOCUMENTATION7
11/19/2025121254230Open ↗
03/03/2010120264123Open ↗
09/28/2009120146724Open ↗
Showing 3 of 7 on file for this type
▸BISADMINISTRATIVE OBJECTIONS5
02/11/2010120264123Open ↗
10/19/2009120181686Open ↗
09/02/2009120146724Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
03/03/2010120264123Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
03/03/2010120264123Open ↗
03/03/2010120264123Open ↗
02/11/2010120264123Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms10
▸BISEFILING COVER SHEET4
02/11/2010120264123Open ↗
10/19/2009120181686Open ↗
09/02/2009120146724Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
04/26/2022141008488Open ↗
03/12/2014140170543Open ↗
07/22/2009120112038Open ↗
▸BISADDITIONAL INFORMATION2
11/19/2025121254230Open ↗
02/10/2023141008488Open ↗
▸BISSRO INTAKE FORM(SRO1)1
09/28/2009120146724Open ↗
▸Other Documents27
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION5
09/28/2009120146724Open ↗
09/02/2009120146724Open ↗
09/02/2009120146724Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSite Survey: Initial4
08/13/2026M00701234-P8Open ↗
08/13/2026M00701234-P6Open ↗
08/13/2026M00701234-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026M00701234-P8Open ↗
08/13/2026M00701234-P6Open ↗
08/13/2026M00701234-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification4
08/23/2026M00701234-A5Open ↗
08/23/2026M00701234-P8Open ↗
08/15/2026M00701234-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWAdjoining Owners Notification2
08/13/2026M00701234-S1Open ↗
08/13/2026M00701234-S2Open ↗
▸DOB NOWCalculations2
08/25/2026M01118325-I1Open ↗
08/13/2026M01118325-P1Open ↗
▸DOB NOWManufacturer's Specifications2
08/25/2026M01118325-I1Open ↗
08/13/2026M01118325-P1Open ↗
▸BISVERIFY DOB PLAN NAMING STANDARD IS MET1
04/26/2022141008488Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
04/26/2022141008488Open ↗
▸BISPLOT DIAGRAM1
11/19/2025121254230Open ↗
▸DOB NOWFinal Survey1
08/13/2026M00701234-I1Open ↗