1895Year Built
4Stories
C6Building Class
R8BZoning
6,465 sfGross Floor Area
7Units
Rent Stabilized0 Open Violations
Walk-up cooperative · Owner of record: 126 WEST 80TH STREETOWNERS CORP. · 2,043 sf lot · 3.16 FAR built · Flood zone X
Locations of Work
Mechanical
Cellar1p · 1 filing · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
126 W80TH ST OWNERS903/22/2026
126 WEST 80TH STREET OWNERS CORP203/22/2026
THE BROWNSTONE SCHOOL103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW YORK ENGINEERING ASSOC., P.C.211/15/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEW YORK ENGINEERING ASSOCIATES P403/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW YORK ENGINEERING ASSO851211/15/2022
Building Lifecycle
All (22)Filed (2)Permit Issued (2)Signed Off (2)Violation (9)Inspection (1)Special Inspection (6)
03/24/2023
Signed off — Alteration
REPLACE BOILER AND OIL BURNER.
M08016952-S1
03/24/2023
Signed off — Alteration
REPLACE BOILER AND OIL BURNER.
M08016952-I1
03/16/2023
Violation issued (HPD, closed)
A
01/19/2023
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
11/19/2022
Permit issued — Boiler Equipment
M08016952-S1-BE
11/15/2022
Filed — Alteration
REPLACE BOILER AND OIL BURNER.
M08016952-S1
10/28/2022
Special inspection requirement — Fuel-Oil Storage and Fuel-Oil Piping Systems
LOUIS ARENA
10/21/2022
Permit issued — Boiler Equipment
M08016952-I1-BE
10/14/2022
Filed — Alteration
REPLACE BOILER AND OIL BURNER.
M08016952-I1
10/06/2022
Special inspection requirement — Heating Systems
LOUIS ARENA
10/06/2022
Special inspection requirement — HVAC-R and service water heating equipment
LOUIS ARENA
10/06/2022
Special inspection requirement — Maintenance information
LOUIS ARENA
10/06/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
LOUIS ARENA
10/06/2022
Special inspection requirement — HVAC-R and service water heating system controls
LOUIS ARENA
12/22/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/28/2021
Violation issued (ECB, closed)
Construction
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/26/2016
Violation issued (HPD, closed)
I
03/18/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/24/1990
Violation issued (ECB, closed)
Boilers
09/24/1990
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentSigned-offALLISON A. HEANEY11/19/2022
DOB NOWBoiler EquipmentSigned-offALLISON A. HEANEY10/21/2022
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
01/19/2023Pass-Final Boiler Equipment InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
10/28/2022Fuel-Oil Storage and Fuel-Oil Piping SystemsLOUIS ARENAspecial
10/06/2022Heating SystemsLOUIS ARENAspecial
10/06/2022HVAC-R and service water heating equipmentLOUIS ARENAenergy_progress
10/06/2022Maintenance informationLOUIS ARENAenergy_progress
10/06/2022HVAC-R and service water piping design and insulationLOUIS ARENAenergy_progress
10/06/2022HVAC-R and service water heating system controlsLOUIS ARENAenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
09/01/2026M08016952-I1Request digital key ↗
09/01/2026M08016952-S1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026M08016952-I1Open ↗
08/13/2026M08016952-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026M08016952-S1Open ↗
09/23/2026M08016952-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/23/2026M08016952-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWHPD-3: Single Room Occupancy Multiple Dwelling (SRO MD) Anti-Harassment Checklist2
08/13/2026M08016952-I1Open ↗
08/13/2026M08016952-S1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026M08016952-I1Open ↗
08/13/2026M08016952-S1Open ↗