← Back
Three families
1265 HERKIMER STREET
BROOKLYN · BIN 3042219
💬 Discuss this project
1920Year Built
3Stories
C0Building Class
R6Zoning
2,700 sfGross Floor Area
3Units
Rent Stabilized1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Three families · 2,000 sf lot · 1.35 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Floor 31p · 1 filing · 20 docs
Floor 2
Floor 1
Cellar2p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GREENBROOK PARTNERS707/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/17/2025$1.2M—— → —$433/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
COMMERCIAL CONSTRUCTION CONSULTING201/06/2026
RIMKUS NEW YORK PLLC101/06/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EAST COAST EXPEDITING303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NTF MANAGEMENT INCGeneral Contractor204/09/2026
P.S.I. MECHANICALPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RIMKUS NEW YORK, PLLC8123101/06/2026
RIMKUS NEW YORK, PLLC9809101/06/2026
Building Lifecycle
All (87)Filed (3)Permit Issued (3)Violation (60)Inspection (5)Special Inspection (16)
04/30/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/22/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/22/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/06/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/06/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/12/2026
Permit issued — Plumbing
B01340015-S2-PL
01/12/2026
Permit issued — General Construction
B01340015-I1-GC
01/09/2026
Permit issued — Mechanical Systems
B01340015-S1-MS
01/06/2026
Filed — Alteration
Mechanical work associated with renovations to existing three family building. No change in occupancy, use or egress.
B01340015-I1
01/06/2026
Filed — Alteration
Mechanical work associated with renovations to existing three family building. No change in occupancy, use or egress.
B01340015-S2
01/06/2026
Filed — Alteration
Mechanical work associated with renovations to existing three family building. No change in occupancy, use or egress.
B01340015-S1
12/29/2025
Special inspection requirement — HVAC-R and service water heating equipment
Kenneth Wagner
12/29/2025
Special inspection requirement — HVAC-R and service water heating system controls
Kenneth Wagner
12/29/2025
Special inspection requirement — Maintenance information
Kenneth Wagner
12/29/2025
Special inspection requirement — Ventilation and air distribution system
Kenneth Wagner
12/26/2025
Special inspection requirement — Fire-Resistance Rated Construction
xueyan zheng
12/26/2025
Special inspection requirement — Fenestration air leakage
xueyan zheng
12/26/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
xueyan zheng
12/26/2025
Special inspection requirement — Fenestration areas
xueyan zheng
12/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
xueyan zheng
12/26/2025
Special inspection requirement — Mechanical Systems
Kenneth Wagner
12/26/2025
Special inspection requirement — Energy Code Compliance Inspections
Kenneth Wagner
12/26/2025
Special inspection requirement — Final
Kenneth Wagner
12/26/2025
Special inspection requirement — Interior lighting power
xueyan zheng
12/26/2025
Special inspection requirement — Masonry
xueyan zheng
12/26/2025
Special inspection requirement — Final
xueyan zheng
12/26/2025
Special inspection requirement — Energy Code Compliance Inspections
xueyan zheng
11/20/2025
Violation issued (HPD, closed)
I
06/09/2025
Violation issued (HPD, closed)
A
11/29/2024
Violation issued (HPD, closed)
I
04/10/2024
Violation issued (HPD, closed)
A
11/22/2023
Violation issued (HPD, closed)
I
03/23/2023
Violation issued (HPD, closed)
A
11/14/2022
Violation issued (HPD, closed)
I
02/25/2022
Violation issued (HPD, closed)
I
02/25/2022
Violation issued (HPD, closed)
A
04/09/2021
Violation issued (HPD, closed)
I
04/09/2021
Violation issued (HPD, closed)
A
07/15/2014
Violation issued (HPD, closed)
B
07/15/2014
Violation issued (HPD, closed)
B
07/15/2014
Violation issued (HPD, closed)
B
07/15/2014
Violation issued (HPD, closed)
B
07/15/2014
Violation issued (HPD, closed)
B
07/15/2014
Violation issued (HPD, closed)
B
07/15/2014
Violation issued (HPD, closed)
B
07/15/2014
Violation issued (HPD, closed)
B
07/15/2014
Violation issued (HPD, closed)
A
05/28/2011
Violation issued (ECB, open)
Construction
11/19/2003
Violation issued (HPD, closed)
B
10/05/2003
Violation issued (HPD, closed)
B
04/16/2003
Violation issued (HPD, closed)
C
08/09/2002
Violation issued (HPD, closed)
B
08/09/2002
Violation issued (HPD, closed)
B
08/09/2002
Violation issued (HPD, closed)
B
08/09/2002
Violation issued (HPD, closed)
B
04/18/2002
Violation issued (HPD, closed)
B
04/18/2002
Violation issued (HPD, closed)
B
04/18/2002
Violation issued (HPD, closed)
C
04/18/2002
Violation issued (HPD, closed)
B
04/18/2002
Violation issued (HPD, closed)
B
Latest 60 of 87 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offP.S.I. MECHANICAL01/12/2026
DOB NOWGeneral ConstructionSigned-offNTF MANAGEMENT INC01/12/2026
DOB NOWMechanical SystemsSigned-offNTF MANAGEMENT INC01/09/2026
1 project · most recent 01/06/2026
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/06/2026Signed-offNTF MANAGEMENT INCHeating Systems, Ventilation Systems
Heating
Stelpro Stelpro Model #AB61508W 1,500 kW · Electric Heater ×13
Stelpro Model #AB41008W 1,000 kW · Electric Heater ×9
Stelpro Model #ASSO1008T2W 1,000 kW · Electric Heater ×6
Stelpro Model #AB82008X 2,000 kW · Electric Heater ×3
Ventilation
Panasonic Panasonic Model # FV-0511VF1 50 CFM · Exhaust Fan ×6
1 project · most recent 01/06/2026
Water/Sanitary
FiledStatusContractorScope
01/06/2026Signed-offP.S.I. MECHANICALWater/Sanitary
1 project · most recent 08/05/2026
General Wiring
FiledStatusContractorScope
08/05/2026CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/30/2026Pass-Final CND-Occupancy InspectionPassView ↗
04/22/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/22/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/06/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/06/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
12/29/2025HVAC-R and service water heating equipmentKenneth Wagnerenergy_progress
12/29/2025HVAC-R and service water heating system controlsKenneth Wagnerenergy_progress
12/29/2025Maintenance informationKenneth Wagnerenergy_progress
12/29/2025Ventilation and air distribution systemKenneth Wagnerenergy_progress
12/26/2025Fire-Resistance Rated Constructionxueyan zhengprogress
12/26/2025Fenestration air leakagexueyan zhengenergy_progress
12/26/2025Fenestration and door U-factor and product ratingsxueyan zhengenergy_progress
12/26/2025Fenestration areasxueyan zhengenergy_progress
12/26/2025Fire-Resistant Penetrations and Jointsxueyan zhengspecial
12/26/2025Mechanical SystemsKenneth Wagnerspecial
12/26/2025Energy Code Compliance InspectionsKenneth Wagnerprogress
12/26/2025FinalKenneth Wagnerprogress
12/26/2025Interior lighting powerxueyan zhengenergy_progress
12/26/2025Masonryxueyan zhengspecial
12/26/2025Finalxueyan zhengprogress
12/26/2025Energy Code Compliance Inspectionsxueyan zhengprogress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/19/2026B01340015-S2Request digital key ↗
08/19/2026B01340015-I1Request digital key ↗
08/19/2026B01340015-S1Request digital key ↗
▸Seals & Professional Certifications19
▸DOB NOWProgress Inspector Seal & Signature13
09/23/2026B01340015-S1Open ↗
09/23/2026B01340015-S1Open ↗
09/23/2026B01340015-S1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/19/2026B01340015-I1Open ↗
08/19/2026B01340015-S1Open ↗
08/19/2026B01340015-S2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026B01340015-S1Open ↗
08/31/2026B01340015-I1Open ↗
08/31/2026B01340015-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/19/2026B01340015-S2Open ↗
08/19/2026B01340015-I1Open ↗
08/19/2026B01340015-S1Open ↗