← Back
Walk-up apt, over six families with stores
1274 1 AVENUE
MANHATTAN · BIN 1045580
💬 Discuss this project
1920Year Built
6Stories
C7Building Class
C2-8Zoning
16,151 sfGross Floor Area
26Units
Rent Stabilized66 Open Violations ▸FISP: SAFE
Walk-up apt, over six families with stores · Owner of record: BARBARA STERN, LLC · 4,000 sf lot · 4.04 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Roof1p · 1 filing · 7 docs
Floor 1Under Construction6p · 1 filing · 15 docs
CellarUnder Construction4p · 1 filing · 15 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AKAM ASSOCIATES2107/08/2026
PRATT CONSTRUCTION1107/08/2026
UNITED KING CONSTRUCTION307/08/2026
1274 DELI CROP304/09/2026
PRATT CONSTRUCTION&REST103/22/2026
ARGON ELECTRICAL CORP103/22/2026
1274 OWNERS103/22/2026
NSC DEVELOPMENT103/22/2026
NONSTOP CONSTRUCTION INC. DBA NSC D103/22/2026
1ST AVE GOURMET203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MK ARCHITECTURE501/22/2026
YOU GAO104/09/2025
MJE PROFESSIONAL SERVICES110/06/2023
FL&M ENGINEERING DESIGN &INSPECTION106/01/2023
ASHRAF CORP207/17/2019
ROYAL ENGINEERING, P.C110/15/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIERARCH-E203/21/2026
HH BUILDING CONSULTING & ARCHITECTU403/21/2026
INDESIGN STUDIO203/21/2026
W J PROFESSIONAL EXPEDITING COMPANY203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRATT CONSTRUCTION & RESTGeneral Contractor807/08/2026
PHOENIX SUTTON STR INCGeneral Contractor403/21/2026
KATAN P & H INCPlumbing207/08/2026
ARGON ELECTRICAL CORPElectrical203/22/2026
ELPO ELECTRICAL CONTG INCElectrical103/22/2026
FRANCHINO, LOUISElectrical103/21/2026
QUINTANA, DAVIDElectrical103/21/2026
DWAIKAT DECOR CORPGeneral Contractor107/08/2026
HNS CORPGeneral Contractor107/08/2026
UNITED KING CONSTRUCTIONGeneral Contractor107/08/2026
NEPTUNE SIGNS AWNINGSScaffold107/08/2026
BOILERMATIC WELDING INDElectrical103/21/2026
CHETRAM, RISHIRAMElectrical103/21/2026
DEO SINGHElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
YOU GAO9407104/09/2025
HRF SERVICES CORP5616108/07/2024
ASR ENGINEERING PC8404106/01/2023
GEIGER ENGINEERING. PC689106/01/2023
Building Lifecycle
All (122)Filed (12)Permit Issued (13)Signed Off (3)Facade (FISP) (14)Violation (60)Inspection (10)Objection (2)Special Inspection (8)
08/14/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/28/2026
Signed off — Alteration
ERECT AN NON-ILLUMINATED SIGN ON WALL.NOT WITHIN VIEW OF ARTERIAL HIGHWAY OR PUBLIC PARK 1/2 ACRE OR MORE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01201980-I1
01/27/2026
Special inspection requirement — Tenant Protection Plan Compliance
01/22/2026
Filed — Alteration
The scope of work consists of adding new sinks (sewer, grease trap and CW/HW) and natural gas lines for cooking & fire suppression gas valve
M01091685-P3
12/30/2025
Special inspection requirement — Tenant Protection Plan Compliance
12/22/2025
Filed — Alteration
The scope of work consists of adding new sinks (sewer, grease trap and CW/HW) and natural gas lines for cooking & fire suppression gas valve
M01091685-P2
12/08/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/27/2025
Special inspection requirement — Tenant Protection Plan Compliance
11/25/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
11/25/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/20/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/30/2025
Permit issued — Plumbing
M01091685-S2-PL
09/01/2025
Violation issued (HPD, closed)
C
07/18/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/02/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/14/2025
Permit issued — Sign
M01201980-I1-SG
04/09/2025
Filed — Alteration
ERECT AN NON-ILLUMINATED SIGN ON WALL.NOT WITHIN VIEW OF ARTERIAL HIGHWAY OR PUBLIC PARK 1/2 ACRE OR MORE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01201980-I1
11/20/2024
Filed — Alteration
The scope of work consists of adding new sinks (sewer, grease trap and CW/HW) and natural gas lines for cooking & fire suppression gas valve
M01091685-P1
11/19/2024
Special inspection requirement — Tenant Protection Plan Compliance
10/11/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/11/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/08/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/19/2024
Permit issued — Plumbing
M01091685-S2-PL
09/09/2024
Filed — Alteration
The scope of work consists of adding new sinks (sewer, grease trap and CW/HW) and natural gas lines for cooking & fire suppression gas valve
M01091685-S2
08/15/2024
Signed off — Alteration
M00865170-I1
08/13/2024
Permit issued — General Construction
M01091685-I1-GC
08/07/2024
Filed — Alteration
The scope of work consists of adding new sinks (sewer, grease trap and CW/HW) and natural gas lines for cooking & fire suppression gas valve
M01091685-I1
06/05/2024
Cycle 9 facade report submitted
05/08/2024
Cycle 9 facade report signed — SAFE
04/25/2024
Cycle 9 facade inspection completed
02/22/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/20/2024
Cycle 9 facade report submitted
02/14/2024
Cycle 9 facade inspection completed
01/18/2024
Permit issued — Suspended Scaffold
M00964140-I1-SC
01/18/2024
Objection resolved — Addressed
12/13/2023
Objection raised — Other
11/28/2023
Filed — Alteration
Suspended scaffold installation and use as per plans filed herewith.
M00964140-I1
10/16/2023
Permit issued — General Construction
M00865170-I1-GC
10/12/2023
Permit issued — Sidewalk Shed
M00942698-I1-SH
10/06/2023
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M00942698-I1
06/01/2023
Filed — Alteration
M00865170-I1
04/25/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
FADY HABEEL
04/25/2023
Special inspection requirement — Final
FADY HABEEL
04/25/2023
Special inspection requirement — Masonry
FADY HABEEL
04/25/2023
Special inspection requirement — Tenant Protection Plan Compliance
AKM RAHMAN
09/14/2022
Violation issued (HPD, open)
B
09/14/2022
Violation issued (HPD, open)
C
09/14/2022
Violation issued (HPD, open)
B
09/14/2022
Violation issued (HPD, open)
A
08/09/2022
Violation issued (ECB, closed)
Construction
08/09/2022
Violation issued (HPD, open)
C
08/09/2022
Violation issued (HPD, closed)
C
06/15/2022
Violation issued (HPD, open)
B
06/15/2022
Violation issued (HPD, open)
A
06/15/2022
Violation issued (HPD, open)
B
06/15/2022
Violation issued (HPD, open)
A
09/03/2021
Violation issued (HPD, open)
B
09/03/2021
Violation issued (HPD, open)
B
09/03/2021
Violation issued (HPD, open)
A
08/27/2021
Violation issued (HPD, open)
A
Latest 60 of 122 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedKATAN P & H INC10/30/2025
DOB NOWSignSigned-offDESTHERS, JOSEPH04/14/2025
DOB NOWPlumbingPermit IssuedKATAN P & H INC09/19/2024
DOB NOWGeneral ConstructionPermit IssuedDWAIKAT DECOR CORP08/13/2024
DOB NOWSuspended ScaffoldPermit IssuedJAVA BUILDERS INC01/18/2024
DOB NOWGeneral ConstructionSigned-offHNS CORP10/16/2023
DOB NOWSidewalk ShedPermit IssuedUNITED KING CONSTRUCTION10/12/2023
DOB NOWSupported ScaffoldPermit IssuedPRATT CONSTRUCTION & RES*09/04/2020
DOB NOWSupported ScaffoldPermit IssuedPRATT CONSTRUCTION & RES*09/25/2019
DOB NOWSupported ScaffoldPermit IssuedPRATT CONSTRUCTION & RES*05/21/2019
DOB NOWSupported ScaffoldPermit IssuedPRATT CONSTRUCTION & RES*01/03/2019
DOB NOWSidewalk ShedSigned-offPHOENIX SUTTON STR INC10/29/2018
DOB NOWSidewalk ShedSigned-offPHOENIX SUTTON STR INC10/16/2018
BISOTISSUEDPRATT CONSTRUCTION & REST02/22/2019
BISOTISSUEDNONSTOP CONSTRUCTION INC09/27/2018
BISPLISSUEDL&J PLG & HTG CO OF NY IN06/01/2018
BISOTISSUEDNONSTOP CONSTRUCTION INC05/04/2018
BISBLISSUEDNEW YORK HEATING CORP04/10/2015
BISPLISSUEDNEW YORK HEATING CORP03/26/2014
BISOTISSUEDNEW YORK HEATING CORP03/26/2014
BISOTISSUEDLC CON INC02/22/2012
BISOTISSUEDKORMAN DESIGN & BUILD01/10/2008
BISFPISSUEDNEW YORK BUSINESS FIRE SYSTEM04/27/2006
BISOTISSUEDGOTHAM INTERIOR CONTRACTING INC01/18/2006
BISEQISSUEDGOTHAM INTERIOR CONTRACTING INC01/18/2006
BISOTISSUEDPLAZA CONTRACTING11/29/2001
BISOTISSUEDPLAZA CONTRACTING INC.11/29/2000
BISEQISSUEDSPRING SCAFFOLDING INC11/15/2000
BIS—ISSUEDNORTH SHORE NEON SIGN12/08/1998
BISPLISSUEDPRIME MECHNICAL CORP12/02/1998
BISOTISSUEDWAVE DANCER LTD11/24/1998
BISPLISSUEDPRIME MECHNICAL10/14/1998
BISFPISSUEDACTIVE FIRE EXTINGUISHER CO INC08/18/1998
BISOTISSUEDL.D.C INDUSTRIES OF NY INC05/15/1991
1 project · most recent 01/22/2026
Gas Water/Sanitary
FiledStatusContractorScope
01/22/2026Permit IssuedKATAN P & H INCGas, Water/Sanitary
11 projects · most recent 10/17/2024
General Wiring
FiledStatusContractorScope
10/17/2024CompleteBRUNI ELECTRIC INCGeneral Wiring
08/15/2024Permit IssuedWCK ELECTRIC CORP.General Wiring
10/06/2023Permit IssuedRICHARD NEU—
10/13/2021CompleteCRESCO ELECTRICAL CORPGeneral Wiring
10/19/2019Permit IssuedSNJ ELECTL CONTRG LLC—
10/15/2018CompleteARGON ELECTRICAL CORPGeneral Wiring
10/15/2018CompleteARGON ELECTRICAL CORPGeneral Wiring
10/11/2018CompleteELPO ELECTRICAL CONTG INC—
03/14/2018CompleteARGON ELECTRICAL CORPGeneral Wiring
02/23/2018CompleteARGON ELECTRICAL CORPGeneral Wiring
01/24/2018CompleteARGON ELECTRICAL CORP—
2 projects · most recent 10/06/2023
Sidewalk Shed Scaffold
FiledStatusContractorScope
10/06/2023Permit IssuedUNITED KING CONSTRUCTIONSidewalk Shed
07/17/2019Permit IssuedPRATT CONSTRUCTION & RES*Scaffold
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
08/14/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/08/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/25/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
11/25/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/20/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/18/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/02/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/11/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/11/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/08/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
01/27/2026Tenant Protection Plan Compliance—special
12/30/2025Tenant Protection Plan Compliance—special
11/27/2025Tenant Protection Plan Compliance—special
11/19/2024Tenant Protection Plan Compliance—special
04/25/2023Structural Stability – Alterations of existing buildingsFADY HABEELspecial
04/25/2023FinalFADY HABEELprogress
04/25/2023MasonryFADY HABEELspecial
04/25/2023Tenant Protection Plan ComplianceAKM RAHMANspecial
▾Documents — 150 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch10
09/06/2026M00088076-I1Request digital key ↗
08/31/2026M00865170-I1Request digital key ↗
08/29/2026M00942698-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸DOB NOWPlans/Sketch - Supported Scaffold2
09/05/2026M00112125-I1Request digital key ↗
08/15/2026M00112125-P1Request digital key ↗
▸Applications & Permits20
▸BISWORK PERMIT APPLICATION13
05/28/2019140814590Open ↗
02/22/2019140814590Open ↗
10/31/2018123544806Open ↗
Showing 3 of 13 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION7
11/01/2018140814590Open ↗
09/20/2018123544806Open ↗
09/20/2018123544806Open ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications37
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION11
12/17/2019140814590Open ↗
03/13/2019123544806Open ↗
02/15/2019140814590Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
09/06/2026M00088076-I1Open ↗
09/05/2026M00112125-I1Open ↗
08/29/2026M00942698-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/23/2026M00865170-I1Open ↗
08/23/2026M00865170-I1Open ↗
08/23/2026M00865170-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
11/01/2018140814590Open ↗
03/24/2014140176057Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
11/01/2018140814590Open ↗
03/24/2014140176057Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
02/24/2012120985461Open ↗
01/09/2008110058455Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
11/01/2018140814590Open ↗
03/24/2014140176057Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
02/24/2012120985461Open ↗
01/09/2008110058455Open ↗
▸BISPC FULL REPORT1
01/09/2008110058455Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026M00865170-I1Open ↗
▸Trade Schedules & Equipment8
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
08/06/2014140176057Open ↗
03/24/2014140176057Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
11/28/2014140176057Open ↗
09/03/2014140176057Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
09/20/2018123544806Open ↗
09/20/2018123544806Open ↗
▸BISBoiler Approval1
11/28/2014140176057Open ↗
▸BISSCHEDULE B - PLUMBING1
03/24/2014140176057Open ↗
▸Safety & Tenant Protection5
▸BISTenant Protection Plan and Notes4
09/20/2018123544806Open ↗
09/20/2018123544806Open ↗
04/16/2018123389564Open ↗
Showing 3 of 4 on file for this type
▸BISSTREET TREE CHECKLIST1
02/24/2012120985461Open ↗
▸Environmental & Asbestos14
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
09/05/2026M00112125-I1Open ↗
08/26/2026M01091685-P3Open ↗
08/26/2026M01091685-P2Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
09/20/2018123544806Open ↗
09/20/2018123544806Open ↗
04/16/2018123389564Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
02/24/2012120985461Open ↗
01/09/2008110058455Open ↗
▸Energy Compliance16
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS7
12/17/2019140814590Open ↗
03/13/2019123544806Open ↗
09/20/2018123544806Open ↗
Showing 3 of 7 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS4
12/17/2019140814590Open ↗
03/13/2019123544806Open ↗
09/05/2018123389564Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
11/01/2018140814590Open ↗
03/24/2014140176057Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
11/01/2018140814590Open ↗
03/24/2014140176057Open ↗
▸BISTECHNICAL REPORT: ENERGY1
02/24/2012120985461Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
11/01/2018140814590Open ↗
03/24/2014140176057Open ↗
▸Approvals, Objections & Sign-offs8
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
12/17/2019140814590Open ↗
03/13/2019123544806Open ↗
09/05/2018123389564Open ↗
Showing 3 of 5 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
02/24/2012120985461Open ↗
11/10/2008110379340Open ↗
01/09/2008110058455Open ↗
▸Cost, Insurance & Ownership13
▸BISCOST AFFIDAVIT13
12/17/2019140814590Open ↗
03/13/2019123544806Open ↗
11/01/2018140814590Open ↗
Showing 3 of 13 on file for this type
▸Filing & Intake Forms10
▸BISEFILING COVER SHEET4
09/20/2018123544806Open ↗
08/29/2018123544806Open ↗
02/24/2012120985461Open ↗
Showing 3 of 4 on file for this type
▸BISBOROUGH INTAKE FORM3
12/17/2019140814590Open ↗
03/13/2019123544806Open ↗
09/05/2018123389564Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
11/01/2018140814590Open ↗
03/24/2014140176057Open ↗
▸BISADDITIONAL INFORMATION1
07/22/2014140176057Open ↗
▸Other Documents5
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
11/01/2018140814590Open ↗
09/27/2018123544806Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026M00964140-I1Open ↗
▸DOB NOWBSA Meeting Minutes/BSA Resolution1
08/13/2026M00088076-I1Open ↗
▸DOB NOWCalculations1
08/13/2026M00964140-I1Open ↗