ECB10/23/2025VF, HOIST MACHINE BRAKE MAINTENANCE TAG EXPIRED PROVIDE.59-BB-7.. FIRE EXTINGUISHER TAG EXPIRED PROVIDE 57-BB-7...$3K due
ECB06/28/2024OBSERVED ON EIGHTH FLOOR KITCHEN SINK AND BATHROOM SINK INSTALLED PVC PIPING ON WASTE LINE. NO P TRAP UNDER SINK IN BATHROOM AND ON THE ROOF WATER LEAKING FROM ROOF TANK ON TO THE ROOF WHICH IS CONTRARY TO CODE$625 due
DOB05/01/2024FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB04/11/2024FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #902509. REMEDY: SUBMIT ACCEPTABLE REQU$1K due
ECB03/16/2023FILED A CERTIFICATE OF CORRECTION OR OTHER RELATED MATERIALS CONTAINING MATERIAL FALSE STATEMENT(S).RESPONDENT FILED A CERTIFICATE OF CORRECTION 12/2/22 FOR NOV #35662038X ISSUED 10/5/22.UPON INSPECTION FOUND T$10K due
DOB02/22/2023FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
ECB01/20/2023ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1/28-118.3.2.OCCUPANCY NOTED BUILDING OCCUPIED WITH COFO#102435161 EXPIRED ON 3/19/2014.PREVIOUS ECB VIO#35662041R.REME$3K due
ECB10/05/2022ALT/CHANGED BLDG OCCUPIED W/O VALID C/O NOTED C/O102435161 EXPIRED3/19/14.NOTED:BLDG FULLY OCCUPIED.OBTAIN VALID C/O.$1K due
DOB09/04/2020V-DOB VIOLATION - ACTIVE
DOB09/06/2019VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
DOB05/20/2019FAILURE TO PERFORM CATEGORY 5 INSPECTION
DOB07/31/2018FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018
DOB04/16/2018V-DOB VIOLATION - ACTIVE
DOB01/26/2018VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB11/14/2016VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
DOB08/30/2013FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012
DOB10/01/2012VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST
DOB12/13/2011VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST
DOB01/08/2009VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
DOB01/08/2009V-DOB VIOLATION - ACTIVE
DOB10/31/2007VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
DOB08/24/2007V-DOB VIOLATION - ACTIVE
DOB08/24/2007V-DOB VIOLATION - ACTIVE
DOB07/12/2007V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
ECB09/07/2017REMOVAL OF SAFETY MEASURES SUCH AS SIDEWALK SHED'S W/OUT DEPT APPROVAL. @ TIME OF INSP BLDG FACADE WAS STILL DESIGNATED AS UNSAFE. THE AMENDED FACADE REPORT (TR6) RECIEVED ON 8/25/2017. HAD NOT BEEN ACCEPTED &Nothing owed — awaiting certificate of correction
ECB01/04/2017FAILURE TO FILE ACCEPTABLE AMENDED REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. AGG1 PRIORNOV 36027447K UNDER 28-302.5. RMDY: FILE ACCEPTABLE AMENDED REPORT.Nothing owed — awaiting certificate of correction
ECB08/28/2015FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 7 REPORT TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW FISP REPORT. REMEDY: FILE AN AMENDED REPORT FOLLOWING REMEDIAL REPAIRNothing owed — awaiting certificate of correction