← Back
Four families
13 LAKE AVENUE
STATEN ISLAND · BIN 5109087
💬 Discuss this project
1931Year Built
2Stories
C3Building Class
R3AZoning
2,240 sfGross Floor Area
4Units
133 Open Violations 132 unresolved · 1 paperwork only ▸FDNY Report ↗
Four families · 5,040 sf lot · 0.44 FAR built · Flood zone X500
Locations of Work
ArchitectureGeneral
Roof1p · 1 filing · 12 docs
Floor 11p · 1 filing · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HPD307/08/2026
STATE CONTRACTING CORP NY203/22/2026
HOUSING PRESERVATION DEVELOPME203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GABY TCHILINGUIRIAN R.A.305/15/2023
JOEL PHAGOO P.E. PLLC111/19/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
M W EXPEDITING603/21/2026
A1 EXPEDITING SERVICE203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NATIONAL HOME IMPROVEMENTGeneral Contractor1203/21/2026
CONDUCTOR ELECL SVCS INCElectrical203/22/2026
STATE CONTRACTING CORP NYGeneral Contractor107/08/2026
AMC PLBG, HTG & CLNG, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GABY TCHILINGUIRIAN R.A.2540207/26/2022
Building Lifecycle
All (41)Filed (4)Permit Issued (6)Signed Off (2)Violation (19)Inspection (2)Special Inspection (8)
12/19/2023
Signed off — Alteration
Plans filed to repair damaged structural components as per plans submitted here-in. Work includes to replace the roof and this filing is to resolve the violating conidtions from violation 39054007J. No change to use, egress or occupancy.
S00716930-I1
11/06/2023
Signed off — Alteration
Plumbing work being filed to repair damaged plumbing components. No change to use, egress or occupancy.
S00871586-I1
09/29/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/10/2023
Permit issued — General Construction
S00716930-I1-GC
06/05/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/30/2023
Permit issued — Plumbing
S00871586-I1-PL
05/15/2023
Filed — Alteration
Plumbing work being filed to repair damaged plumbing components. No change to use, egress or occupancy.
S00871586-I1
12/21/2022
Permit issued — General Construction
S00716930-I1-GC
10/21/2022
Permit issued — General Construction
S00716930-I1-GC
09/14/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/05/2022
Permit issued — General Construction
S00716930-I1-GC
07/26/2022
Filed — Alteration
Plans filed to repair damaged structural components as per plans submitted here-in. Work includes to replace the roof and this filing is to resolve the violating conidtions from violation 39054007J. No change to use, egress or occupancy.
S00716930-P1
07/25/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
GABY TCHILINGUIRIAN
07/25/2022
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
GABY TCHILINGUIRIAN
07/25/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
GABY TCHILINGUIRIAN
07/25/2022
Special inspection requirement — Final
GABY TCHILINGUIRIAN
07/25/2022
Special inspection requirement — Fire-Resistance Rated Construction
GABY TCHILINGUIRIAN
07/25/2022
Special inspection requirement — Insulation placement and R values
GABY TCHILINGUIRIAN
07/25/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
GABY TCHILINGUIRIAN
07/25/2022
Special inspection requirement — Interior lighting power
GABY TCHILINGUIRIAN
07/19/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/19/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/13/2022
Filed — Alteration
Plans filed to repair damaged structural components as per plans submitted here-in. Work includes to replace the roof and this filing is to resolve the violating conidtions from violation 39054007J. No change to use, egress or occupancy.
S00716930-I1
04/13/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/31/2022
Violation issued (ECB, closed)
Construction
03/31/2022
Violation issued (ECB, closed)
Construction
01/10/2022
Violation issued (ECB, open)
Construction
11/20/2021
Permit issued — Sidewalk Shed
S00628427-I1-SH
11/19/2021
Filed — Alteration
INSTALLATION OF HEAVY DUTY SIDEWALK SHED DURING BLDG DEMOLITION, FILED SEP. SIDEWALK SHED SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. SHED ON ROADWAY. DOT PERMITS BY OTHERS.
S00628427-I1
04/29/2019
Violation issued (DOB, closed)
V%-DOB VIOLATION
05/18/2015
Violation issued (HPD, closed)
C
05/18/2015
Violation issued (HPD, closed)
C
05/18/2015
Violation issued (HPD, closed)
C
05/12/2015
Violation issued (HPD, closed)
C
05/12/2015
Violation issued (HPD, closed)
C
01/28/2014
Violation issued (HPD, closed)
C
01/28/2014
Violation issued (HPD, closed)
C
01/28/2014
Violation issued (HPD, closed)
C
01/07/2014
Violation issued (HPD, closed)
C
01/07/2014
Violation issued (HPD, closed)
C
01/07/2014
Violation issued (HPD, closed)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offNATIONAL HOME IMPROVEMENT07/10/2023
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC05/30/2023
DOB NOWGeneral ConstructionSigned-offNATIONAL HOME IMPROVEMENT12/21/2022
DOB NOWGeneral ConstructionSigned-offNATIONAL HOME IMPROVEMENT10/21/2022
DOB NOWGeneral ConstructionSigned-offNATIONAL HOME IMPROVEMENT08/05/2022
DOB NOWSidewalk ShedPermit IssuedSTATE CONTRACTING CORP NY11/20/2021
BIS—ISSUEDSTATE CONTRACTING CORP NY12/13/2021
BISEQISSUEDSTATE CONTRACTING CORP NY12/13/2021
2 projects · most recent 12/07/2023
General Wiring
FiledStatusContractorScope
12/07/2023CompleteCONDUCTOR ELECL SVCS INCGeneral Wiring
11/19/2021CompleteNASH ELECTRIC SERVICES IN—
1 project · most recent 11/19/2021
Sidewalk Shed
FiledStatusContractorScope
11/19/2021Permit IssuedSTATE CONTRACTING CORP NYSidewalk Shed
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
09/29/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/05/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
07/25/2022Fire-Resistant Penetrations and JointsGABY TCHILINGUIRIANspecial
07/25/2022Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)GABY TCHILINGUIRIANspecial
07/25/2022Structural Stability – Alterations of existing buildingsGABY TCHILINGUIRIANspecial
07/25/2022FinalGABY TCHILINGUIRIANprogress
07/25/2022Fire-Resistance Rated ConstructionGABY TCHILINGUIRIANprogress
07/25/2022Insulation placement and R valuesGABY TCHILINGUIRIANenergy_progress
07/25/2022Fenestration and door U-factor and product ratingsGABY TCHILINGUIRIANenergy_progress
07/25/2022Interior lighting powerGABY TCHILINGUIRIANenergy_progress
▾Documents — 51 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/25/2026S00628427-I1Request digital key ↗
08/24/2026S00716930-I1Request digital key ↗
08/24/2026S00716930-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION3
03/01/2023520463169Open ↗
11/29/2021520463169Open ↗
10/13/2021520463169Open ↗
▸BISWORK PERMIT APPLICATION2
12/13/2021520463169Open ↗
12/13/2021520463169Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/23/2026S00871586-I1Open ↗
08/13/2026S00716930-I1Open ↗
08/13/2026S00628427-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/25/2026S00716930-P1Open ↗
08/25/2026S00716930-P1Open ↗
08/25/2026S00716930-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026S00716930-P1Open ↗
08/25/2026S00716930-P1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
02/08/2022520463169Open ↗
▸Trade Schedules & Equipment6
▸BISGAS CUT-OFF2
12/13/2021520463169Open ↗
12/13/2021520463169Open ↗
▸BISWATER CUT-OFF2
12/13/2021520463169Open ↗
12/13/2021520463169Open ↗
▸BISSEWER CONNECTION: DEP SD1 & SD21
12/13/2021520463169Open ↗
▸BISELECTRIC CUT-OFF1
02/08/2022520463169Open ↗
▸Safety & Tenant Protection7
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE5
12/13/2021520463169Open ↗
12/13/2021520463169Open ↗
12/13/2021520463169Open ↗
Showing 3 of 5 on file for this type
▸BISSRO MD ANTI-HARASSMENT CHECKLIST1
12/13/2021520463169Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
12/13/2021520463169Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/23/2026S00871586-I1Open ↗
08/13/2026S00716930-I1Open ↗
08/13/2026S00716930-P1Open ↗
▸BISRODENT CONTROL1
12/13/2021520463169Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026S00716930-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISADMINISTRATIVE OBJECTIONS1
10/13/2021520463169Open ↗
▸BISLANDMARKS SIGNOFF1
12/13/2021520463169Open ↗
▸Cost, Insurance & Ownership3
▸BISDEPT OF FINANCE VERIFICATION2
02/08/2022520463169Open ↗
12/13/2021520463169Open ↗
▸BISPROJECT-SPECIFIC GL INSURANCE1
12/13/2021520463169Open ↗
▸Filing & Intake Forms3
▸BISBOROUGH INTAKE FORM2
11/29/2021520463169Open ↗
10/13/2021520463169Open ↗
▸BISEFILING COVER SHEET1
10/13/2021520463169Open ↗
▸Other Documents6
▸BISLAA - Supporting Documentation5
12/13/2021520463169Open ↗
12/13/2021520463169Open ↗
12/13/2021520463169Open ↗
Showing 3 of 5 on file for this type
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
02/08/2022520463169Open ↗