← Back
Two stories - detached, small or mid-size
130-17 120 STREET
QUEENS · South Ozone Park · BIN 4254040
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R3-2Zoning
1,232 sfGross Floor Area
1Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 2,400 sf lot · 0.51 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalGeneral
Roof5p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/08/2020$688K—Private party → Private party$558/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC110/01/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRANSFORM ELECTL CONTRS IElectrical103/22/2026
SOLAR CONTRACTING LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854110/01/2025
Building Lifecycle
All (16)Filed (1)Permit Issued (1)Signed Off (1)Violation (8)Special Inspection (5)
01/08/2026
Signed off — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONIC GENERATING SYSTEM.ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEING APPROVED AND/OR PERMITTED BY THENYC DEPARTMENT OF BUILDINGS.NO CHANGE TO USE, EGRESS OR OCCUPANCY.
Q01294633-I1
10/31/2025
Permit issued — Solar
Q01294633-I1-SL
10/01/2025
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONIC GENERATING SYSTEM.ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEING APPROVED AND/OR PERMITTED BY THENYC DEPARTMENT OF BUILDINGS.NO CHANGE TO USE, EGRESS OR OCCUPANCY.
Q01294633-I1
09/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
09/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
09/29/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
09/29/2025
Special inspection requirement — Final
TOM PETERSEN
09/29/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
11/07/2019
Violation issued (HPD, closed)
I
10/23/2018
Violation issued (ECB, closed)
Construction
08/22/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/18/2018
Violation issued (ECB, closed)
Construction
07/14/2018
Violation issued (ECB, closed)
Construction
05/25/2018
Violation issued (ECB, closed)
Construction
05/25/2018
Violation issued (ECB, closed)
Construction
05/25/2018
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSOLAR CONTRACTING LLC10/31/2025
3 projects · most recent 10/01/2025
General Wiring
FiledStatusContractorScope
10/01/2025CompleteVILLAGE ELECTL CONTRS INC—
06/11/2025Permit IssuedBERGER QUALITY ELEC'L CON—
10/01/2018CompleteTRANSFORM ELECTL CONTRS IGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
09/29/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
09/29/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
09/29/2025Energy Code Compliance InspectionsTOM PETERSENprogress
09/29/2025FinalTOM PETERSENprogress
09/29/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026Q01294633-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/28/2026Q01294633-I1Open ↗
08/28/2026Q01294633-I1Open ↗
08/28/2026Q01294633-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026Q01294633-I1Open ↗
08/28/2026Q01294633-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/18/2026Q01294633-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/18/2026Q01294633-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01294633-I1Open ↗