← Back
One story - permanent living quarter
130-19 231 STREET
QUEENS · Laurelton · BIN 4278038
💬 Discuss this project
1936Year Built
1.5Stories
A2Building Class
R2AZoning
1,500 sfGross Floor Area
1Units
One story - permanent living quarter · 4,000 sf lot · 0.38 FAR built · Flood zone X
Locations of Work
Electrical
Roof3p · 1 filing · 13 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/20/2017$448K—Private party → Private party$299/sf building
08/15/2016$320K—Private party → INTERACTIVE RESOLUTIONS, INC.$213/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR211/13/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ISLAND ELECTRIC CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281211/13/2025
Building Lifecycle
All (12)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (8)
11/18/2025
Signed off — Alteration
INSTALLATION OF SOLAR PANELS, ROOFTOP, RAILED, GRID-TIED, 15 MODULES, 6.45KW
Q01235190-I1
11/14/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
11/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
11/14/2025
Special inspection requirement — Final
Mina Makar
11/14/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
11/13/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS, ROOFTOP, RAILED, GRID-TIED, 15 MODULES, 6.45KW
Q01235190-P1
11/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
11/13/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
11/13/2025
Special inspection requirement — Final
Mina Makar
11/13/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
06/11/2025
Permit issued — Solar
Q01235190-I1-SL
06/03/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS, ROOFTOP, RAILED, GRID-TIED, 15 MODULES, 6.45KW
Q01235190-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offMOMENTUM SOLAR06/11/2025
1 project · most recent 06/17/2025
FiledStatusContractorScope
06/17/2025CompleteISLAND ELECTRIC CORP—
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
11/14/2025Air barrier - visual inspectionMina Makarenergy_progress
11/14/2025Fire-Resistant Penetrations and JointsMina Makarspecial
11/14/2025FinalMina Makarprogress
11/14/2025Energy Code Compliance InspectionsMina Makarprogress
11/13/2025Fire-Resistant Penetrations and JointsMina Makarspecial
11/13/2025Energy Code Compliance InspectionsMina Makarprogress
11/13/2025FinalMina Makarprogress
11/13/2025Air barrier - visual inspectionMina Makarenergy_progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026Q01235190-P1Request digital key ↗
08/20/2026Q01235190-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
09/17/2026Q01235190-I1Open ↗
09/17/2026Q01235190-I1Open ↗
08/27/2026Q01235190-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026Q01235190-I1Open ↗
08/13/2026Q01235190-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/17/2026Q01235190-I1Open ↗
08/27/2026Q01235190-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026Q01235190-I1Open ↗
08/13/2026Q01235190-P1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01235190-I1Open ↗