← Back
One story - permanent living quarter
130-27 231 STREET
QUEENS · Laurelton · BIN 4278036
💬 Discuss this project
1945Year Built
1.67Stories
A2Building Class
R2AZoning
1,426 sfGross Floor Area
1Units
One story - permanent living quarter · Owner of record: DUNN TRUST, DATED SEPTMEBER 29, 2022 · 4,000 sf lot · 0.36 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 17 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC205/15/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor203/21/2026
BERGER QUALITY ELEC'L CONElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854205/15/2025
Building Lifecycle
All (14)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (10)
07/09/2025
Signed off — Alteration
Q01206232-I1
05/16/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
05/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/16/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
05/16/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/16/2025
Special inspection requirement — Final
TOM PETERSEN
05/15/2025
Filed — Alteration
Q01206232-P1
05/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/15/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
05/15/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/15/2025
Special inspection requirement — Final
TOM PETERSEN
05/15/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
04/08/2025
Permit issued — Solar
Q01206232-I1-SL
04/04/2025
Filed — Alteration
Q01206232-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP04/08/2025
1 project · most recent 06/17/2025
FiledStatusContractorScope
06/17/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
05/16/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
05/16/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/16/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
05/16/2025Energy Code Compliance InspectionsTOM PETERSENprogress
05/16/2025FinalTOM PETERSENprogress
05/15/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/15/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
05/15/2025Energy Code Compliance InspectionsTOM PETERSENprogress
05/15/2025FinalTOM PETERSENprogress
05/15/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026Q01206232-P1Request digital key ↗
08/20/2026Q01206232-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
09/02/2026Q01206232-I1Open ↗
09/02/2026Q01206232-I1Open ↗
09/02/2026Q01206232-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/02/2026Q01206232-I1Open ↗
09/02/2026Q01206232-I1Open ↗
08/31/2026Q01206232-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026Q01206232-P1Open ↗
08/20/2026Q01206232-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026Q01206232-P1Open ↗
08/20/2026Q01206232-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01206232-I1Open ↗