C8-1Zoning
12,436 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Miscellaneous store building · Owner of record: 130-35 MERRICK BOULEVARD ASSOCIATES, LLC · 32,946 sf lot · 0.38 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Roof32p · 6 filings · 20 docs
Floor 152p · 5 filings · 20 docs
Basement1p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NU3S7009/13/2026
CACTUS HOLDINGS707/08/2026
TERRAZOLA BUILDERS603/22/2026
130-35 MERRICK BOULEVARD103/22/2026
RE-BRICK CONSTRUCTION103/22/2026
NUMW JAMAICA LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/25/2014$3.0M—— → —$237/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SALEH & ASSOCIATES1203/27/2026
NY BUILDING ASSOCIATES INC203/04/2026
STUDIO HUJI208/28/2025
ZENITH HOME INSPECTIONS207/18/2025
ASHRAF CORP111/27/2024
SALEH AND ASSOCIATES LLC109/26/2024
AA BLDG & INSP SVC LLC409/05/2024
SELF EMPLOYED208/05/2022
JAMINET ENGINEERING105/24/2022
ENTHINK ENGINEERS LLC101/13/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Younes Abouyaala PE203/21/2026
B2 CODE CONSULTANTS3203/21/2026
BUILDING BROTHERS203/21/2026
SIGNS CAD403/21/2026
S R SOLAR DESIGN403/21/2026
JP EXPEDITE403/21/2026
AN TONG FAN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TERRAZOLA BUILDERS LLCGeneral Contractor2507/08/2026
CT IDEAL SUPPRESSIONGeneral Contractor303/21/2026
W.JAKE CONSTRUCTION CORPGeneral Contractor303/21/2026
RE-BRICK CONSTRUCTION INCGeneral Contractor303/21/2026
VALLESIGNS AWNINGSScaffold207/08/2026
DRM CONSTRUCTION CORPGeneral Contractor204/09/2026
770 ELECTRIC CORPGeneral Contractor104/09/2026
RICHARD NEUElectrical103/22/2026
VALLESIGNS & AWNINGS INCGeneral Contractor107/08/2026
JOSEPH WEINSTEIN ELECTRICElectrical103/22/2026
BES MECHANICAL LLCPlumbing107/08/2026
DYNAMIC PLBG & SPRKLR CORPlumbing107/08/2026
QMB PLUMBING & HEATING INCPlumbing107/08/2026
GRID CITY ELECTRIC, CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244203/04/2026
AA BUILDING & INSPECTION15191101/07/2026
NORMAN C. LOK818108/27/2025
JAY KAVI CORPORATION8500111/27/2024
CROSSCHECK INSPECTION SER544105/24/2022
Building Lifecycle
All (154)Filed (28)Permit Issued (29)Signed Off (9)Violation (8)Inspection (12)Objection (38)Special Inspection (30)
03/30/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/27/2026
Filed — Alteration
New plumbing, drainage fixtures & piping related to renovation and new addition. No change to use, egress or occupancy.
Q00612477-P4
03/13/2026
Signed off — Alteration
ERECT ILLUMINATED, ACCESSORY BUSINESS WALL SIGN WITH BACKER PANEL, NO CHANGE TO USE, EGRESS OR OCCUPATION
Q01119312-I1
03/12/2026
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
03/11/2026
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
Q01105948-I1
03/04/2026
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
Q01105948-P1
02/27/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/26/2026
Special inspection requirement — Final
NARESH MAHANGU
02/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
02/26/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
02/26/2026
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
02/25/2026
Special inspection requirement — Vestibules
Younes Abouyaala
02/25/2026
Special inspection requirement — Masonry
Younes Abouyaala
02/25/2026
Special inspection requirement — Interior lighting power
Younes Abouyaala
02/25/2026
Special inspection requirement — Fenestration air leakage
Younes Abouyaala
02/25/2026
Special inspection requirement — Sprayed fire-resistant materials
Younes Abouyaala
02/25/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
02/25/2026
Special inspection requirement — Lighting controls
Younes Abouyaala
02/25/2026
Special inspection requirement — Fenestration areas
Younes Abouyaala
02/25/2026
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
02/25/2026
Special inspection requirement — Fire-Resistance Rated Construction
Younes Abouyaala
02/25/2026
Special inspection requirement — Insulation placement and R values
Younes Abouyaala
02/25/2026
Special inspection requirement — Exterior lighting power
Younes Abouyaala
02/25/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Younes Abouyaala
02/24/2026
Objection resolved — Addressed
02/24/2026
Objection resolved — Addressed
02/24/2026
Objection resolved — Addressed
02/24/2026
Objection resolved — Addressed
02/24/2026
Objection resolved — Addressed
02/24/2026
Objection resolved — Addressed
02/24/2026
Objection resolved — Addressed
02/24/2026
Objection resolved — Addressed
02/12/2026
Objection raised — Zoning
02/12/2026
Objection raised — Admin
02/12/2026
Objection raised — Scope
02/12/2026
Objection raised — Accessibility
02/12/2026
Objection raised — Structural
02/12/2026
Objection raised — Fire_Protection
02/12/2026
Objection raised — Fire_Protection
02/12/2026
Objection raised — Zoning
01/23/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/16/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/16/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/14/2026
Signed off — Alteration
INSTALL A LILLUMINATED ACCESSORY DOUBLE-FACED PYLON SIGN INSIDE PROPERTY - PYLON STRUCTURE TO BE FILED SEPARATE JOB APPLICATION.
Q01259486-I1
01/14/2026
Signed off — Alteration
Q01259536-I1
01/09/2026
Permit issued — Mechanical Systems
Q00612427-I1-MS
01/07/2026
Filed — Alteration
New HVAC system for entire building. No change to use, egress or occupancy.
Q00612427-P3
12/29/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
Renovation of an existing one-story building to become a car wash and auto service center. Construction of a one-story addition to be a cafe. Create an open parking lot with (24) spaces.
Q00489815-P2
12/20/2025
Filed — Alteration
New plumbing, drainage fixtures & piping related to renovation and new addition. No change to use, egress or occupancy.
Q00612477-P3
12/10/2025
Signed off — Alteration
New steel framing and concrete work at building addition. No Change to use, egress or occupancy.
Q00613003-I1
12/10/2025
Signed off — Alteration
Q00785820-I1
09/19/2025
Special inspection requirement — Wood – Seismic Resistance
Younes Abouyaala
09/09/2025
Permit issued — Structural
Q01259536-I1-ST
09/09/2025
Permit issued — Sign
Q01259486-I1-SG
09/08/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/03/2025
Permit issued — General Construction
Q00489815-I1-GC
08/28/2025
Filed — Alteration
INSTALL A LILLUMINATED ACCESSORY DOUBLE-FACED PYLON SIGN INSIDE PROPERTY - PYLON STRUCTURE TO BE FILED SEPARATE JOB APPLICATION.
Q01259486-I1
08/27/2025
Filed — Alteration
Q01259536-I1
07/22/2025
Special inspection requirement — Final
Ryan Hung
07/21/2025
Special inspection requirement — Final
ADITYA DESAI
Latest 60 of 154 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offTERRAZOLA BUILDERS LLC01/09/2026
DOB NOWStructuralSigned-offVALLESIGNS & AWNINGS INC09/09/2025
DOB NOWSignSigned-offVALLESIGNS & AWNINGS INC09/09/2025
DOB NOWGeneral ConstructionPermit IssuedTERRAZOLA BUILDERS LLC09/03/2025
DOB NOWGeneral ConstructionPermit IssuedTERRAZOLA BUILDERS LLC07/10/2025
DOB NOWMechanical SystemsSigned-offCT IDEAL SUPPRESSION01/22/2025
DOB NOWPlumbingSigned-offQMB PLUMBING & HEATING INC11/15/2024
DOB NOWSolarSigned-off770 ELECTRIC CORP11/13/2024
DOB NOWSignSigned-offVALLESIGNS & AWNINGS INC10/07/2024
DOB NOWConstruction FencePermit IssuedTERRAZOLA BUILDERS LLC09/18/2024
DOB NOWGeneral ConstructionPermit IssuedTERRAZOLA BUILDERS LLC09/17/2024
DOB NOWStructuralSigned-offTERRAZOLA BUILDERS LLC07/30/2024
DOB NOWPlumbingPermit IssuedCITYWIDE PLBG HTG & SPKLS02/23/2024
DOB NOWGeneral ConstructionPermit IssuedTERRAZOLA BUILDERS LLC01/29/2024
DOB NOWConstruction FencePermit IssuedTERRAZOLA BUILDERS LLC01/05/2024
DOB NOWGeneral ConstructionSigned-offTERRAZOLA BUILDERS LLC06/02/2023
DOB NOWGeneral ConstructionSigned-offTERRAZOLA BUILDERS LLC06/02/2023
DOB NOWSupport of ExcavationSigned-offTERRAZOLA BUILDERS LLC06/02/2023
DOB NOWPlumbingPermit IssuedL AND I MECH. CONTRS. INC05/17/2023
DOB NOWStructuralSigned-offTERRAZOLA BUILDERS LLC04/26/2023
DOB NOWStructuralSigned-offDRM CONSTRUCTION CORP03/09/2023
DOB NOWStructuralSigned-offDRM CONSTRUCTION CORP02/10/2023
DOB NOWMechanical SystemsSigned-offTERRAZOLA BUILDERS LLC02/02/2023
DOB NOWConstruction FencePermit IssuedTERRAZOLA BUILDERS LLC02/02/2023
DOB NOWGeneral ConstructionPermit IssuedTERRAZOLA BUILDERS LLC11/09/2022
DOB NOWGeneral ConstructionPermit IssuedTERRAZOLA BUILDERS LLC11/04/2022
DOB NOWGeneral ConstructionPermit IssuedTERRAZOLA BUILDERS LLC11/03/2022
DOB NOWSidewalk ShedSigned-offRE-BRICK CONSTRUCTION INC02/18/2022
DOB NOWGeneral ConstructionSigned-offW.JAKE CONSTRUCTION CORP01/27/2022
BISOTISSUEDTEMPERATURE AIR CO INC08/08/1997
BISPLISSUEDNEWRY P&H10/29/1996
BISOTISSUEDDBA JACK SHELLY GENERAL CONT10/16/1996
1 project · most recent 01/07/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/07/2026Signed-offTERRAZOLA BUILDERS LLCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Trane YSC048G3RLB 1,500 CFM · Rooftop Unit ×6
YSC036G3RLB 1,000 CFM · Rooftop Unit ×3
YSC102H3RMA 2,800 CFM · Rooftop Unit ×3
Mitsubishi Electric MSUZ-FS06NA 9,000 BTU · Heat Pump Outdoor ×3
Heating
Modine HD60 60,000 BTU · Electric Heater ×21
HD30 30,000 BTU · Electric Heater ×3
Ventilation
Pennbarry DX08R 171 CFM · Exhaust Fan ×2
DX11Q 511 CFM · Exhaust Fan ×2
FX18B 5,123 CFM · Exhaust Fan ×2
SX095QC 199 CFM ×2
Greenheck G-070-D 230 CFM · Exhaust Fan ×3
CUBE-200-20 5,100 CFM · Exhaust Fan ×1
G-060-VG 150 CFM · Exhaust Fan ×1
G-100HP-VG 400 CFM · Exhaust Fan ×1
SQ-97-VG 100 CFM · Exhaust Fan ×1
2 projects · most recent 03/27/2026
Water/Sanitary Gas Storm
FiledStatusContractorScope
03/27/2026Permit IssuedDYNAMIC PLBG & SPRKLR CORGas, Storm, Water/Sanitary
12/29/2025Signed-offNYC MAINMAN CORPWater/Sanitary
9 projects · most recent 05/11/2026
General Wiring
FiledStatusContractorScope
05/11/2026CompleteJOSEPH WEINSTEIN ELECTRICGeneral Wiring
02/13/2026Permit IssuedSIGNS CAD CORP—
12/18/2025Permit IssuedDVM ELECTRICAL SERVICES L2 meters, 1 new_meters
05/02/2025CompleteSPECTRUM ON BROADWAY-ELEC—
01/08/2025CompleteGRID CITY ELECTRIC, CORP1 meters, 1 new_meters
03/16/2023CancelledFVC ELECTRIC, INCGeneral Wiring
12/07/2022Permit IssuedHOME RUN ELECTRICGeneral Wiring
02/26/2022Permit IssuedFVC ELECTRIC, INCGeneral Wiring
01/13/2022CompleteRICHARD NEU—
1 project · most recent 05/19/2022
Fence
FiledStatusContractorScope
05/19/2022Permit IssuedTERRAZOLA BUILDERS LLCFence
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
03/30/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/12/2026Fail-Final CND-Occupancy InspectionFailView ↗
02/27/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/23/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/16/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/16/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/08/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/21/2024Pass-Final House ConnectionPassView ↗
08/27/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/24/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/28/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/27/2023Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 83
DateRequirementInspectorRole
02/26/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
02/26/2026Air barrier - visual inspectionNARESH MAHANGUenergy_progress
02/26/2026FinalNARESH MAHANGUprogress
02/26/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
02/25/2026Sprayed fire-resistant materialsYounes Abouyaalaspecial
02/25/2026Fire-Resistance Rated ConstructionYounes Abouyaalaprogress
02/25/2026MasonryYounes Abouyaalaspecial
02/25/2026Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
02/25/2026Fenestration and door U-factor and product ratingsYounes Abouyaalaenergy_progress
02/25/2026Exterior lighting powerYounes Abouyaalaenergy_progress
02/25/2026Insulation placement and R valuesYounes Abouyaalaenergy_progress
02/25/2026Fenestration air leakageYounes Abouyaalaenergy_progress
02/25/2026Lighting controlsYounes Abouyaalaenergy_progress
02/25/2026VestibulesYounes Abouyaalaenergy_progress
02/25/2026Fenestration areasYounes Abouyaalaenergy_progress
02/25/2026Interior lighting powerYounes Abouyaalaenergy_progress
02/25/2026Energy Code Compliance InspectionsYounes Abouyaalaprogress
09/19/2025Wood – Seismic ResistanceYounes Abouyaalaspecial
07/22/2025FinalRyan Hungprogress
07/21/2025FinalADITYA DESAIprogress
05/27/2025Energy Code Compliance InspectionsYounes Abouyaalaprogress
05/27/2025Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
05/27/2025MasonryYounes Abouyaalaspecial
05/27/2025Sprayed fire-resistant materialsYounes Abouyaalaspecial
05/27/2025Fire-Resistance Rated ConstructionYounes Abouyaalaprogress
Latest 25 of 83.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Nu3s Autocare CenterOtherFloor 1, Roof
Project Q00612427 Alteration · Permit Entire · 11/22/2021
Project Q00612477 Alteration · Permit Entire · 11/22/2021
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 116 on file (BIS + DOB NOW)
▸Plans & Drawings28
▸DOB NOWPlans/Sketch28
08/26/2026Q00661613-I1Request digital key ↗
08/26/2026Q00666689-I1Request digital key ↗
08/26/2026Q00613003-I1Request digital key ↗
Showing 3 of 28 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026Q00489815-P2Open ↗
08/13/2026Q00489815-P1Open ↗
08/13/2026Q00489815-I1Open ↗
▸Seals & Professional Certifications57
▸DOB NOWDPL-1: Design Professional Seal & Signature28
08/26/2026Q00666689-I1Open ↗
08/26/2026Q00714643-I1Open ↗
08/26/2026Q00785820-I1Open ↗
Showing 3 of 28 on file for this type
▸DOB NOWProgress Inspector Seal & Signature16
09/18/2026Q00489815-I1Open ↗
09/18/2026Q00489815-I1Open ↗
09/01/2026Q01259486-I1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
09/18/2026Q00489815-I1Open ↗
08/28/2026Q01122017-I1Open ↗
08/28/2026Q01122017-I1Open ↗
Showing 3 of 13 on file for this type
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/13/2026Q00489815-P2Open ↗
08/13/2026Q00489815-I1Open ↗
08/13/2026Q00489815-P1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00489815-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form7
08/26/2026Q00666689-I1Open ↗
08/21/2026Q00612139-I1Open ↗
08/21/2026Q00489815-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026Q01105948-P1Open ↗
08/21/2026Q01105948-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01105948-I1Open ↗
▸Cost, Insurance & Ownership2
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026Q00489815-I1Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026Q00489815-I1Open ↗
▸Other Documents12
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026Q00489815-P1Open ↗
08/13/2026Q00489815-I1Open ↗
08/13/2026Q00489815-P2Open ↗
▸DOB NOWSURVEY: INITIAL3
08/13/2026Q00489815-I1Open ↗
08/13/2026Q00489815-P1Open ↗
08/13/2026Q00489815-P2Open ↗
▸DOB NOWAdjoining Owners Notification3
08/13/2026Q00785820-I1Open ↗
08/13/2026Q00612139-I1Open ↗
08/13/2026Q00714643-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026Q00489815-I1Open ↗
08/13/2026Q00489815-P2Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026Q00489815-I1Open ↗