← Back
One story retail building
128 COURT STREET
💬 Discuss this project
1912Year Built
1Stories
K1Building Class
R6Zoning
28,150 sfGross Floor Area
1Units
LL97 Covered6 Open Violations ▸
One story retail building · Owner of record: 130 COURT LLC · 14,518 sf lot · 1.94 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingGeneralOther
Roof18p · 5 filings · 20 docs
Floor 24p · 1 filing · 2 docs
Floor 119p · 3 filings · 20 docs
Mezzanine21p · 2 filings · 20 docs
Cellar48p · 6 filings · 20 docs
Sub-Basement1p · 1 filing · 6 docs
Site & exterior18p · 3 filings · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Two Trees Management4207/08/2026
130 COURT STREET1503/21/2026
INDEPENDENCE COMMUNITY BANK503/21/2026
TWO TREES MGMT CO LLX203/21/2026
INDEPENDENCE SAVINGS BANK203/21/2026
130 COURT LLC103/22/2026
INDEPENDENCE BANK103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PEROTTO CONSULTING MANAGEMENT3003/21/2026
SYNERGY BUILDING CONSULTANTS303/21/2026
KD DESIGNS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ARSENAL SCAFFOLD INCGeneral Contractor607/08/2026
RETAIL PROJECT MANGEMENTGeneral Contractor307/08/2026
NAT'L MECH. SVCS PLBG LLCPlumbing207/08/2026
THE METRO GROUP PLBG LLCPlumbing207/08/2026
MACCARONE PLUMBING INCPlumbing107/08/2026
THE METRO GROUP, INCGeneral Contractor107/08/2026
AFGO MECHANICAL SVCS INCGeneral Contractor107/08/2026
RRP PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AK ENGINEERING PC678403/11/2026
NEW YORK ENGINEERING ASSO851609/17/2025
VINCENT J. LIOTTA P. E.1974104/16/2025
FREDERICK TAYLOR ASSOCIAT1076211/20/2024
Building Lifecycle
All (150)Filed (21)Permit Issued (15)Signed Off (13)Violation (60)Inspection (11)Special Inspection (30)
06/11/2026
Filed — Alteration
8858 - Herewith filing for plumbing portion of boiler replacement and associated piping/equipment. No change in egress, Use Group or occupancy group.
B01038348-P2
04/22/2026
Signed off — Alteration
8858- Filing for minor interior renovation associated with boiler replacement filed under separate applications. No change in Egress Usegroup or Occuapncy Group. Professional Certification requested.
B01038152-I1
04/22/2026
Signed off — Alteration
8858- Filing for Associated mechanical equipment required for Boiler Replacement. Fresh Air Intake, Breaching, Air Dampers etc.. no change in egress use group or occupancy.
B01038360-I1
04/22/2026
Signed off — Alteration
8858 - Replacing Two Boilers and two Burners. No change to egress use group or occupancy group. Pro Cert requested.
B01031810-I1
04/20/2026
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
04/15/2026
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
04/13/2026
Signed off — Alteration
8947- Filing for new dunnage and replacement of display/Ref/Freezer fixtures associated with replaced Refrigeration equipment filed under separate applications. Remodel bathrooms, aux. rm.No change in Egress Use group or Occupancy Group. Pro Cert Req
B01217178-I1
04/10/2026
Signed off — Alteration
8947- Filing for new dunnage and replacement of display/Ref/Freezer fixtures associated with replaced Refrigeration equipment filed under separate applications. Remodel bathrooms, aux. rm.No change in Egress Use group or Occupancy Group. Pro Cert Req
B01217178-S1
03/11/2026
Filed — Alteration
8947- Filing for new dunnage and replacement of display/Ref/Freezer fixtures associated with replaced Refrigeration equipment filed under separate applications. Remodel bathrooms, aux. rm.No change in Egress Use group or Occupancy Group. Pro Cert Req
B01217178-P2
03/11/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ari Kamo
01/16/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ari Kamo
11/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/10/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/10/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/15/2025
Violation issued (ECB, open)
Boilers
10/15/2025
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
10/02/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/19/2025
Special inspection requirement — Heating Systems
LOUIS ARENA
09/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
LOUIS ARENA
09/17/2025
Filed — Alteration
8858 - Replacing Two Boilers and two Burners. No change to egress use group or occupancy group. Pro Cert requested.
B01031810-P2
09/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
LOUIS ARENA
09/08/2025
Special inspection requirement — Heating Systems
LOUIS ARENA
08/01/2025
Filed — Alteration
8947- Filing for new dunnage and replacement of display/Ref/Freezer fixtures associated with replaced Refrigeration equipment filed under separate applications. Remodel bathrooms, aux. rm.No change in Egress Use group or Occupancy Group. Pro Cert Req
B01217178-P1
08/01/2025
Special inspection requirement — Post-installed Anchors
Ari Kamo
08/01/2025
Special inspection requirement — Final
Ari Kamo
08/01/2025
Special inspection requirement — Fire-Resistance Rated Construction
Ari Kamo
07/23/2025
Special inspection requirement — Post-installed Anchors
Ari Kamo
07/23/2025
Special inspection requirement — Final
Ari Kamo
07/23/2025
Special inspection requirement — Fire-Resistance Rated Construction
Ari Kamo
07/18/2025
Permit issued — Plumbing
B01217178-S1-PL
05/30/2025
Filed — Alteration
8947- Filing for new dunnage and replacement of display/Ref/Freezer fixtures associated with replaced Refrigeration equipment filed under separate applications. Remodel bathrooms, aux. rm.No change in Egress Use group or Occupancy Group. Pro Cert Req
B01217178-S1
05/29/2025
Filed — Alteration
8947- Filing for new dunnage and replacement of display/Ref/Freezer fixtures associated with replaced Refrigeration equipment filed under separate applications. Remodel bathrooms, aux. rm.No change in Egress Use group or Occupancy Group. Pro Cert Req
B01217178-I1
05/29/2025
Special inspection requirement — Fire-Resistance Rated Construction
LOUIS ARENA
05/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
LOUIS ARENA
05/29/2025
Special inspection requirement — Final
LOUIS ARENA
05/28/2025
Filed — Alteration
8858- Filing for minor interior renovation associated with boiler replacement filed under separate applications. No change in Egress Usegroup or Occuapncy Group. Professional Certification requested.
B01038152-P1
05/19/2025
Filed — Alteration
8858 - Herewith filing for plumbing portion of boiler replacement and associated piping/equipment. No change in egress, Use Group or occupancy group.
B01038348-P1
05/02/2025
Signed off — Alteration
REPLACEMENT OF A 2 TON SPLIT SYSTEM LOCATED IN THE ELEVATOR MACHINE ROOM IN THE BASEMENT. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
B01195517-I1
04/18/2025
Permit issued — Mechanical Systems
B01195517-I1-MS
04/16/2025
Filed — Alteration
REPLACEMENT OF A 2 TON SPLIT SYSTEM LOCATED IN THE ELEVATOR MACHINE ROOM IN THE BASEMENT. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
B01195517-I1
04/07/2025
Permit issued — Plumbing
B01038348-I1-PL
04/07/2025
Permit issued — Boiler Equipment
B01031810-I1-BE
03/26/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/14/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
03/14/2025
Special inspection requirement — Mechanical Systems
Vincent Liotta
03/14/2025
Special inspection requirement — Final
Vincent Liotta
03/14/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Vincent Liotta
03/14/2025
Special inspection requirement — Maintenance information
Vincent Liotta
03/14/2025
Special inspection requirement — HVAC-R and service water heating equipment
Vincent Liotta
03/14/2025
Special inspection requirement — HVAC-R and service water heating system controls
Vincent Liotta
02/20/2025
Signed off — Alteration
8907-MH herewith filing for bathroom fans and modifying existing duct work on mezzanine level as per plans. No change in egress usegroup or occupancy group. Procert requested.
B01127499-S1
02/19/2025
Signed off — Alteration
8907-MH herewith filing for bathroom fans and modifying existing duct work on mezzanine level as per plans. No change in egress usegroup or occupancy group. Procert requested.
B01127499-S2
02/18/2025
Signed off — Alteration
8907-MH herewith filing for bathroom fans and modifying existing duct work on mezzanine level as per plans. No change in egress usegroup or occupancy group. Procert requested.
B01127499-I1
01/28/2025
Signed off — Alteration
Installation of temporary material hoist per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
B00935335-I1
01/28/2025
Signed off — Alteration
Installation of temporary heavy duty sidewalk shed per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
B00935297-I1
01/28/2025
Signed off — Alteration
Installation of temporary supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
B00935326-I1
01/24/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/08/2025
Filed — Alteration
8858 - Replacing Two Boilers and two Burners. No change to egress use group or occupancy group. Pro Cert requested.
B01031810-P1
01/07/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
LOUIS ARENA
Latest 60 of 150 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offRRP PLUMBING CORP07/18/2025
DOB NOWMechanical SystemsSigned-offAFGO MECHANICAL SVCS04/18/2025
DOB NOWPlumbingPermit IssuedTHE METRO GROUP PLBG LLC04/07/2025
DOB NOWBoiler EquipmentSigned-offTHE METRO GROUP PLBG LLC04/07/2025
DOB NOWGeneral ConstructionSigned-offRETAIL PROJECT MANGEMENT12/05/2024
DOB NOWPlumbingSigned-offMACCARONE PLUMBING INC12/05/2024
DOB NOWMechanical SystemsSigned-offRETAIL PROJECT MANGEMENT12/04/2024
DOB NOWGeneral ConstructionSigned-offRETAIL PROJECT MANGEMENT08/14/2024
DOB NOWMechanical SystemsSigned-offTHE METRO GROUP, INC08/13/2024
DOB NOWBoiler EquipmentSigned-offNAT'L MECH. SVCS PLBG LLC08/09/2024
DOB NOWPlumbingPermit IssuedNAT'L MECH. SVCS PLBG LLC08/01/2024
DOB NOWSupported ScaffoldSigned-offARSENAL SCAFFOLD INC03/19/2024
DOB NOWSupported ScaffoldSigned-offARSENAL SCAFFOLD INC10/13/2023
DOB NOWSidewalk ShedSigned-offARSENAL SCAFFOLD INC10/13/2023
DOB NOWProtection and Mechanical MethodsSigned-offARSENAL SCAFFOLD INC10/13/2023
BISOTISSUEDRETAIL PROJECT MANGEMENT10/20/2017
BISEQISSUEDARSENAL SCAFFOLD INC08/23/2017
BISEQISSUEDARSENAL SCAFFOLD INC08/21/2017
BISOTISSUEDRETAIL PROJECT MANGEMENT04/26/2017
BISEQISSUEDARSENAL SCAFFOLD INC08/24/2016
BISEQISSUEDARSENAL SCAFFOLD INC08/20/2016
BISOTISSUEDAFGO MECHANICAL SVCS INC01/27/2014
BISPLISSUEDDUO PLUMBING & HTG CORP.05/17/2010
BISOTISSUEDONE MAIN CONSTRUCTION02/10/2009
BISMHISSUEDRETAIL PROJECT MANGEMENT05/20/2008
BISPLISSUEDDUO PLUMBING & HTG CORP.03/25/2008
BISMHISSUEDONE MAIN CONSTRUCTION03/19/2008
BISOTISSUEDRETAIL PROJECT MANGEMENT03/14/2008
BIS—ISSUEDBERGER SIGNS INC03/06/2008
BIS—ISSUEDBERGER SIGNS INC02/14/2008
BIS—ISSUEDBERGER SIGNS INC02/14/2008
BIS—ISSUEDBERGER SIGNS INC02/14/2008
BIS—ISSUEDBERGER SIGNS INC02/13/2008
BIS—ISSUEDBERGER SIGNS INC02/13/2008
BIS—ISSUEDTWO TREES KG LLC09/25/2007
BISMHISSUEDONE MAIN CONSTRUCTION06/18/2007
BISOTISSUEDONE MAIN CONSTRUCTION06/15/2007
BISMHISSUEDINTER-COUNTY MECHANICAL CORP06/28/2002
BISMHISSUEDJOHN DELORENZO & BRO., INC.06/29/2001
BISMHISSUEDJOHN DELORENZO & BRO., INC.03/01/2001
+ 8 more permits on file
1 project · most recent 06/11/2026
Gas
FiledStatusContractorScope
06/11/2026Permit IssuedTHE METRO GROUP PLBG LLCGas
4 projects · most recent 01/22/2026
General Wiring
FiledStatusContractorScope
01/22/2026CompleteSOLID STATE ELECTRIC LLCGeneral Wiring
11/13/2025Permit IssuedPOWER UP NYC ELECTRIC CORGeneral Wiring
02/02/2025CompleteECS ELEC'L CONTG SERV INCGeneral Wiring
09/21/2023CompleteNASH ELECTRIC SERVICES IN—
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
04/20/2026Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
04/15/2026Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
11/13/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/10/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/10/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/15/2025Pass-Final Boiler Equipment InspectionPassView ↗
10/02/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/26/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/14/2025Fail-Final CND-Occupancy InspectionFailView ↗
01/24/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/07/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 31
DateRequirementInspectorRole
03/11/2026Fire-Resistant Penetrations and JointsAri Kamospecial
01/16/2026Fire-Resistant Penetrations and JointsAri Kamospecial
09/19/2025Heating SystemsLOUIS ARENAspecial
09/19/2025Fire-Resistant Penetrations and JointsLOUIS ARENAspecial
09/08/2025Fire-Resistant Penetrations and JointsLOUIS ARENAspecial
09/08/2025Heating SystemsLOUIS ARENAspecial
08/01/2025Post-installed AnchorsAri Kamospecial
08/01/2025FinalAri Kamoprogress
08/01/2025Fire-Resistance Rated ConstructionAri Kamoprogress
07/23/2025Post-installed AnchorsAri Kamospecial
07/23/2025FinalAri Kamoprogress
07/23/2025Fire-Resistance Rated ConstructionAri Kamoprogress
05/29/2025Fire-Resistance Rated ConstructionLOUIS ARENAprogress
05/29/2025Fire-Resistant Penetrations and JointsLOUIS ARENAspecial
05/29/2025FinalLOUIS ARENAprogress
03/14/2025Mechanical SystemsVincent Liottaspecial
03/14/2025FinalVincent Liottaprogress
03/14/2025HVAC-R and service water piping design and insulationVincent Liottaenergy_progress
03/14/2025Maintenance informationVincent Liottaenergy_progress
03/14/2025HVAC-R and service water heating equipmentVincent Liottaenergy_progress
03/14/2025HVAC-R and service water heating system controlsVincent Liottaenergy_progress
12/26/2024Fire-Resistant Penetrations and JointsLOUIS ARENAspecial
12/26/2024Heating SystemsLOUIS ARENAspecial
10/15/2024FinalJeffrey Taylorprogress
10/15/2024Mechanical SystemsJeffrey Taylorspecial
Latest 25 of 31.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Trader Joe'sRetailCellar
Project B01031810 Alteration · LOC Issued · 07/18/2024
Project B01038348 Alteration · Permit Entire · 07/18/2024
Project B01038152 Alteration · LOC Issued · 07/16/2024
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 272 on file (BIS + DOB NOW)
▸Plans & Drawings19
▸DOB NOWPlans/Sketch19
08/26/2026B00935297-I1Request digital key ↗
08/25/2026B01016043-I1Request digital key ↗
08/24/2026B01038360-I1Request digital key ↗
Showing 3 of 19 on file for this type
▸Applications & Permits50
▸BISPLAN / WORK APPROVAL APPLICATION17
03/07/2017321409999Open ↗
08/22/2016340414803Open ↗
08/18/2016340414180Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWLPC Approval/Permit17
08/21/2026B01038348-P2Open ↗
08/21/2026B01217178-I1Open ↗
08/21/2026B01217178-S1Open ↗
Showing 3 of 17 on file for this type
▸BISWORK PERMIT APPLICATION15
10/23/2017321409999Open ↗
10/23/2017321409999Open ↗
08/24/2017340414180Open ↗
Showing 3 of 15 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
01/25/2010310026888Open ↗
▸Seals & Professional Certifications72
▸DOB NOWDPL-1: Design Professional Seal & Signature20
08/25/2026B01016043-I1Open ↗
08/23/2026B01127499-S1Open ↗
08/23/2026B01127499-S2Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature16
09/23/2026B01031810-I1Open ↗
09/23/2026B01031810-I1Open ↗
09/01/2026B01127499-S2Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWProgress Inspector Seal & Signature10
09/01/2026B01127499-S2Open ↗
09/01/2026B01127499-I1Open ↗
09/01/2026B01127499-I1Open ↗
Showing 3 of 10 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
11/20/2017340414803Open ↗
11/20/2017340414180Open ↗
03/07/2017321409999Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
03/07/2017321409999Open ↗
01/10/2014320824499Open ↗
05/28/2009310026888Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
03/07/2017321409999Open ↗
08/22/2016340414803Open ↗
08/18/2016340414180Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
08/22/2016340414803Open ↗
08/18/2016340414180Open ↗
▸BISPC FULL REPORT2
02/20/2008310104534Open ↗
09/20/2007310026888Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
08/22/2016340414803Open ↗
08/18/2016340414180Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
05/28/2009310026888Open ↗
09/20/2007310026888Open ↗
▸Trade Schedules & Equipment9
▸BISSCHEDULE B - PLUMBING4
02/05/2009310140530Open ↗
10/28/2008310104534Open ↗
05/30/2008310140530Open ↗
Showing 3 of 4 on file for this type
▸BISSELF-CERT PLUMBING NOTICE2
03/26/2009310140530Open ↗
11/17/2008310104534Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
03/07/2017321409999Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
09/02/2010310238310Open ↗
▸BISSPRINKLER INSP REPORT : FP-851
03/26/2009310140530Open ↗
▸Safety & Tenant Protection2
▸BISTENANT PROTECTION PLAN AND NOTES2
08/22/2016340414803Open ↗
08/18/2016340414180Open ↗
▸Environmental & Asbestos47
▸DOB NOWDEP ACP-5: Asbestos Assessment Report16
08/23/2026B01127499-I1Open ↗
08/23/2026B01127499-S2Open ↗
08/23/2026B01127499-S1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWOER: Notice to Proceed14
08/21/2026B01038348-P2Open ↗
08/21/2026B01038348-I1Open ↗
08/21/2026B01217178-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWOER: Notice of Satisfaction9
08/23/2026B01031810-I1Open ↗
08/21/2026B01038152-I1Open ↗
08/21/2026B01217178-S1Open ↗
Showing 3 of 9 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
12/19/2008310238310Open ↗
07/03/2008310140530Open ↗
02/15/2008310104534Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
03/07/2017321409999Open ↗
08/22/2016340414803Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED2
08/22/2016340414803Open ↗
08/18/2016340414180Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
09/20/2007310026888Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
03/07/2017321409999Open ↗
01/10/2014320824499Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
08/18/2016340414180Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
08/22/2016340414803Open ↗
08/18/2016340414180Open ↗
▸Approvals, Objections & Sign-offs32
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST16
11/20/2017340414803Open ↗
11/20/2017340414180Open ↗
08/07/2012310026888Open ↗
Showing 3 of 16 on file for this type
▸BISADMINISTRATIVE OBJECTIONS5
01/10/2014320824499Open ↗
12/19/2008310238310Open ↗
05/12/2008310140530Open ↗
Showing 3 of 5 on file for this type
▸BISLANDMARKS APPROVAL4
08/22/2016340414803Open ↗
08/18/2016340414180Open ↗
11/05/2009310026888Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE4
10/20/2009310026888Open ↗
11/27/2007310026888Open ↗
11/13/2007310026888Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
01/10/2014320824499Open ↗
09/23/2010310238310Open ↗
09/23/2010310238310Open ↗
▸Cost, Insurance & Ownership10
▸BISCOST AFFIDAVIT10
03/07/2017321409999Open ↗
01/10/2014320824499Open ↗
09/23/2010310238310Open ↗
Showing 3 of 10 on file for this type
▸Filing & Intake Forms13
▸BISADDITIONAL INFORMATION6
11/20/2017340414803Open ↗
11/20/2017340414180Open ↗
12/03/2009310104534Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING COVER SHEET3
03/07/2017321409999Open ↗
01/10/2014320824499Open ↗
12/19/2008310238310Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
08/22/2016340414803Open ↗
08/18/2016340414180Open ↗
▸BISBOROUGH INTAKE FORM2
11/20/2017340414803Open ↗
11/20/2017340414180Open ↗
▸Other Documents13
▸DOB NOWProof of Historic Building12
08/21/2026B01038348-P2Open ↗
08/21/2026B01217178-I1Open ↗
08/13/2026B01038360-I1Open ↗
Showing 3 of 12 on file for this type
▸BISMonitoring Report-1 (MR-1)1
05/05/2017321409999Open ↗