HPD06/06/2026§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER (SHOE) USING APPROPRIATE NUTS AND BOLTS AT NORTH EXTERIOR WALL (BUILDING FRONT) AT FIRE ESCAPE
DOB02/20/2025CYCLE 9C UNSAFE REPORT FILED
DOB02/22/2024FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
DOB11/05/2021FTM-BLDG SUSTAIND FIRE DMG 11/4/21.DMG NOTED @7 FL,OPN ROOF@SOUTH,WATR DAMAGE ,COLLAPSED CEILINGS.MISSING &BROKEN WINDOWS, DEBRIS@ HALLWAYS & FIRE ESCAPES.CHARRED JOIST NOTED AT ROOF OWNER ENGAGE NYSPE&CONTRCTR-REPAIR BUILDING UNDER PERMIT,FILE PERMIT BY 01/15/21. START WORK BY 01/12/22
DOB11/04/2021EWO-MASONRY WALL+INTERIOR STL COLUMNS& BEAMS&WOOD FRAMED FLOOR SUSTAIN FIRE DAMAGE ON 11/04/21.FLOOR IS OPEN & LINES C,D,E,F&G LOOSE DEBRIS NOTED @ WINDOWS,FIRE ESCAPES & HALLWAYS & INTERIOR STAIR. IMMEDIATELY PROVIDE TEMPORARY ROOF,CLEAN DEBRIS FROM HALLWAYS,FIRE ESCAPES&WINDOWS PROVD PHYSL PARTITN@HALWAYS SEP.LINES D,E,F&G.FILE PRMT 48HRS WRK STRT
DOB04/29/2021FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB04/07/2020V-DOB VIOLATION - ACTIVE
DOB05/02/2019FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
HPD01/04/2019§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROXIMATELY 8 SQ FT AT CEILING IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 4E, 4th STORY, 4th APARTMENT FROM EAST AT SOUTH
HPD01/04/2019§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROXIMATELY 4 SQ FT AT NORTH WALL IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 4E, 4th STORY, 4th APARTMENT FROM EAST AT SOUTH
HPD01/04/2019§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROXIMATELY 6 SQ FT AT EAST WALL IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 4E, 4th STORY, 4th APARTMENT FROM EAST AT SOUTH
HPD01/04/2019§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROXIMATELY 2 SQ FT AT SOUTH WALL IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 4E, 4th STORY, 4th APARTMENT FROM EAST AT SOUTH
HPD10/05/2018§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT EAST WALL ( 16 SQ FT ) IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD05/23/2018§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 4E, 3rd STORY, 4th APARTMENT FROM SOUTH AT WEST
HPD05/23/2018§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 4E, 3rd STORY, 4th APARTMENT FROM SOUTH AT WEST
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB06/10/2015VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST
HPD05/17/2015§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 5B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
DOB05/15/2014VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
DOB03/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
DOB12/31/2013FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013
DOB10/01/2012VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST
ECB03/23/201697X10. FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE EQUIPMENT ELEVATOR AS PER BC3001 2827-987 DOB RECORDS SHOW DEVICE IS ACTIVE. UPON INSPECTION DEVICE WAS FOUND OUT OF SERVICE CREATING A HAZNothing owed — awaiting certificate of correction
ECB06/16/201599BB05,98BB05,24X10,05M10,03X1039Q03,67X10. 24-REPAIR INDICATORS FOR HALL BUTTON STATIONS. ALL FLOORS. 05-PROVIDE CAR DOOR RESTRICTOR; 03- REPAIR FAN IN ELEV CAB; 39-COVER MISSING EXPOSED ELECTRICAL WIRING;67Nothing owed — awaiting certificate of correction
ECB04/22/201372M10,17H10,68M07,40M07,03X10. 72-AS PER APPRX K03; 17-FOR LOBBY HOISTWAY DOOR; 68-AS PER A17.1 8.6.1.2 MAINTENANCE PROGRAM SCHEDULE LOG;40-MISSING ELEVATOR MAINTENANCE CO STICKER & EMERGENCY PHONE #;03-FAN INNothing owed — awaiting certificate of correction
ECB09/21/201199BB05 40M07 17H10 72M10. 40-ELEV MACHINE ROOM MISSING ELEV MAINTENANCE CO & 24 HR EMERGENCY NUMBER & MAINTENANCE LOG. 17-LOBBY HOISTWAY DOOR GIBS.Nothing owed — awaiting certificate of correction