← Back
BuildNYC
Two stories - detached, small or mid-size
1303 RICHMOND AVENUE
STATEN ISLAND · BIN 5029957
💬 Discuss this project
1931Year Built
2Stories
A1Building Class
R3XZoning
2,025 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 1,968 sf lot · 1.03 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalPlumbingFire ProtectionCivilGeneralOther
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 235p · 1 filing · 20 docs
Floor 1Fence installation and building exterior work52p · 2 filings · 20 docs
Cellar36p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SI Northshoer Enterprises1607/08/2026
Kion Development403/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Rogers Calvanico Group612/09/2021
William Montague Engineering103/15/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Zaim ContractorGeneral Contractor707/08/2026
Zaim ContractorScaffold407/08/2026
JB Buzco PlumbingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SRA Planning & Expediting5677312/09/2021
Building Lifecycle
03/25/2022
Signed off — Alteration
ALTERATION INCLUDES REMOVAL OF 292.73 SF AT THE REAR OF EXISTING BUILDING. PROPOSED EXTENSION OF EXISTING FOUNDATION WITH NEW FOUNDATION WALLS, FOOTING, EXTERIOR & INTERIOR PARTITIONS. DECREASE IN FLOOR AREA FROM 2317.35 SF TO 2024.62 SF. C OF O REQ.
S00475214-I1
03/14/2022
Signed off — Alteration
ALTERATION INCLUDES REMOVAL OF 292.73 SF AT THE REAR OF EXISTING BUILDING. PROPOSED EXTENSION OF EXISTING FOUNDATION WITH NEW FOUNDATION WALLS, FOOTING, EXTERIOR & INTERIOR PARTITIONS. DECREASE IN FLOOR AREA FROM 2317.35 SF TO 2024.62 SF. C OF O REQ.
S00475214-S2
03/14/2022
Permit renewed — General Construction
Renewed without changes
S00475214-I1-GC-CX
02/25/2022
Inspection — Pass-Final CO-Alt-1 Inspection Up to 4 Total Levels
Pass
View inspection ↗
02/17/2022
Signed off — Alteration
S00484787-I1
54 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offSuffolk Construction Co03/14/2022
DOB NOWCurb CutSigned-offSuffolk Construction Co12/01/2021
DOB NOWConstruction FenceSigned-offSuffolk Construction Co11/30/2021
DOB NOWPlumbingSigned-offJB Buzco Plumbing07/21/2021
DOB NOWConstruction FenceSigned-offSuffolk Construction Co06/25/2021
DOB NOWFoundationSigned-offSuffolk Construction Co06/25/2021
DOB NOWStructuralSigned-offSuffolk Construction Co03/31/2021
DOB NOWConstruction FenceSigned-offSuffolk Construction Co03/18/2021
1 project · most recent 12/29/2021
General Wiring
FiledStatusContractorScope
12/29/2021CompleteRidge ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
02/25/2022Pass-Final CO-Alt-1 Inspection Up to 4 Total LevelsPassView ↗
02/14/2022Fail-Final Curb Cut Non-Directive 14FailView ↗
01/07/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/15/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/14/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/19/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/19/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
12/09/2021Air barrier - visual inspectionWILLIAM MONTAGUEenergy_progress
12/09/2021Concrete - Cast-In-PlaceWILLIAM MONTAGUEspecial
12/09/2021Fire-Resistant Penetrations and JointsWILLIAM MONTAGUEspecial
12/09/2021Structural Stability – Alterations of existing buildingsWILLIAM MONTAGUEspecial
12/09/2021Subgrade InspectionsWILLIAM MONTAGUEspecial
12/09/2021Energy Code Compliance InspectionsWILLIAM MONTAGUEprogress
12/09/2021FinalWILLIAM MONTAGUEprogress
12/09/2021Fire-Resistance Rated ConstructionWILLIAM MONTAGUEprogress
12/09/2021Footing and FoundationWILLIAM MONTAGUEprogress
12/09/2021Structural Wood FrameWILLIAM MONTAGUEprogress
12/09/2021Interior lighting powerWILLIAM MONTAGUEenergy_progress
12/09/2021Fenestration air leakageWILLIAM MONTAGUEenergy_progress
12/09/2021Fenestration areasWILLIAM MONTAGUEenergy_progress
12/09/2021Fenestration and door U-factor and product ratingsWILLIAM MONTAGUEenergy_progress
08/06/2021Concrete - Cast-In-PlaceWILLIAM MONTAGUEspecial
08/06/2021Fire-Resistant Penetrations and JointsWILLIAM MONTAGUEspecial
08/06/2021Structural Stability – Alterations of existing buildingsWILLIAM MONTAGUEspecial
08/06/2021Subgrade InspectionsWILLIAM MONTAGUEspecial
08/06/2021Energy Code Compliance InspectionsWILLIAM MONTAGUEprogress
08/06/2021FinalWILLIAM MONTAGUEprogress
08/06/2021Fire-Resistance Rated ConstructionWILLIAM MONTAGUEprogress
08/06/2021Footing and FoundationWILLIAM MONTAGUEprogress
08/06/2021Structural Wood FrameWILLIAM MONTAGUEprogress
08/06/2021Air barrier - visual inspectionWILLIAM MONTAGUEenergy_progress
08/06/2021Fenestration areasWILLIAM MONTAGUEenergy_progress
Latest 25 of 28.
68 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account