← Back
Three families
1309 NEEDHAM AVENUE
BRONX · Williamsbridge-Olinville · BIN 2059948
💬 Discuss this project
1910Year Built
2Stories
C0Building Class
R5Zoning
2,712 sfGross Floor Area
3Units
Rent Stabilized4 Open Violations ▸
Three families · 2,375 sf lot · 1.14 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 17 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/22/2014$580K—— → —$214/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC203/05/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802203/05/2025
Building Lifecycle
All (74)Filed (2)Permit Issued (1)Signed Off (1)Violation (60)Special Inspection (10)
04/30/2026
Violation issued (HPD, open)
A
06/05/2025
Violation issued (HPD, open)
A
04/08/2025
Signed off — Alteration
X01157485-I1
03/06/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
03/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
03/06/2025
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
03/06/2025
Special inspection requirement — Final
Kaijin Liang
03/06/2025
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
03/05/2025
Filed — Alteration
X01157485-P1
03/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
03/05/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
03/05/2025
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
03/05/2025
Special inspection requirement — Final
Kaijin Liang
03/05/2025
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
12/30/2024
Permit issued — Solar
X01157485-I1-SL
12/18/2024
Filed — Alteration
X01157485-I1
04/03/2024
Violation issued (HPD, open)
A
11/16/2023
Violation issued (HPD, closed)
I
03/17/2023
Violation issued (HPD, open)
A
11/04/2022
Violation issued (HPD, closed)
I
02/17/2022
Violation issued (HPD, closed)
A
04/05/2021
Violation issued (HPD, closed)
A
11/14/2017
Violation issued (HPD, closed)
I
10/31/2016
Violation issued (HPD, closed)
I
10/05/2015
Violation issued (HPD, closed)
I
04/20/2006
Violation issued (HPD, closed)
B
04/20/2006
Violation issued (HPD, closed)
A
04/20/2006
Violation issued (HPD, closed)
C
04/20/2006
Violation issued (HPD, closed)
B
04/20/2006
Violation issued (HPD, closed)
B
04/20/2006
Violation issued (HPD, closed)
A
04/20/2006
Violation issued (HPD, closed)
A
04/20/2006
Violation issued (HPD, closed)
B
04/20/2006
Violation issued (HPD, closed)
B
04/20/2006
Violation issued (HPD, closed)
B
04/20/2006
Violation issued (HPD, closed)
B
04/20/2006
Violation issued (HPD, closed)
A
04/20/2006
Violation issued (HPD, closed)
B
04/20/2006
Violation issued (HPD, closed)
A
04/20/2006
Violation issued (HPD, closed)
A
04/20/2006
Violation issued (HPD, closed)
A
04/20/2006
Violation issued (HPD, closed)
B
04/20/2006
Violation issued (HPD, closed)
C
01/30/2006
Violation issued (HPD, closed)
B
01/30/2006
Violation issued (HPD, closed)
B
01/30/2006
Violation issued (HPD, closed)
B
01/30/2006
Violation issued (HPD, closed)
B
01/30/2006
Violation issued (HPD, closed)
A
01/30/2006
Violation issued (HPD, closed)
B
01/30/2006
Violation issued (HPD, closed)
B
01/30/2006
Violation issued (HPD, closed)
A
01/30/2006
Violation issued (HPD, closed)
A
01/30/2006
Violation issued (HPD, closed)
B
01/30/2006
Violation issued (HPD, closed)
C
01/30/2006
Violation issued (HPD, closed)
A
01/30/2006
Violation issued (HPD, closed)
B
01/12/2006
Violation issued (HPD, closed)
B
01/12/2006
Violation issued (HPD, closed)
B
01/12/2006
Violation issued (HPD, closed)
C
01/12/2006
Violation issued (HPD, closed)
C
Latest 60 of 74 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP12/30/2024
1 project · most recent 12/11/2024
FiledStatusContractorScope
12/11/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
03/06/2025Structural Stability – Alterations of existing buildingsKaijin Liangspecial
03/06/2025Fire-Resistant Penetrations and JointsKaijin Liangspecial
03/06/2025Energy Code Compliance InspectionsKaijin Liangprogress
03/06/2025FinalKaijin Liangprogress
03/06/2025Air barrier - visual inspectionKaijin Liangenergy_progress
03/05/2025Fire-Resistant Penetrations and JointsKaijin Liangspecial
03/05/2025Structural Stability – Alterations of existing buildingsKaijin Liangspecial
03/05/2025Energy Code Compliance InspectionsKaijin Liangprogress
03/05/2025FinalKaijin Liangprogress
03/05/2025Air barrier - visual inspectionKaijin Liangenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026X01157485-P1Request digital key ↗
08/20/2026X01157485-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026X01157485-P1Open ↗
09/01/2026X01157485-P1Open ↗
09/01/2026X01157485-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026X01157485-P1Open ↗
09/01/2026X01157485-P1Open ↗
08/23/2026X01157485-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026X01157485-P1Open ↗
08/20/2026X01157485-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026X01157485-P1Open ↗
08/20/2026X01157485-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01157485-I1Open ↗