← Back
City residence, one family
131 KANE STREET
BROOKLYN · BIN 3003492
💬 Discuss this project
1840Year Built
3Stories
A4Building Class
R6Zoning
2,672 sfGross Floor Area
1Units
Rent Stabilized0 Open Violations
City residence, one family · Owner of record: 131 KANE LLC · 1,443 sf lot · 1.85 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Floor 323p · 2 filings · 20 docs
Floor 221p · 2 filings · 20 docs
Floor 121p · 2 filings · 20 docs
Cellar25p · 2 filings · 20 docs
Basement20p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PSA BROOKLYN DEVELOPMENT LLC2707/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/20/2022$2.8M—Private party → 131 KANE LLC$1,029/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CQ&J CORPORATION1108/12/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WM ARCH2003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MORELL BUILDERS INCGeneral Contractor507/08/2026
PLBG P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
D&E BUILD EVERGREEN I9342308/12/2026
NKM ENGINEERING PLLC6244210/03/2024
CL ENGINEERING P.C.6781405/31/2024
Building Lifecycle
All (64)Filed (11)Permit Issued (4)Signed Off (3)Violation (10)Inspection (6)Special Inspection (30)
09/18/2026
Signed off — Alteration CO
CONVERT EXISITNG 4 DWELLING UNITS INTO 1 FAMILY UNIT WITH INTERIOR WORK AS PER PLANS. OBTAIN NEW C OF O .
B00839282-I1
08/12/2026
Filed — Alteration CO
CONVERT EXISITNG 4 DWELLING UNITS INTO 1 FAMILY UNIT WITH INTERIOR WORK AS PER PLANS. OBTAIN NEW C OF O .
B00839282-P5
06/01/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/05/2026
Violation issued (HPD, closed)
A
09/18/2025
Special inspection requirement — Duct leakage testing, insulation and design
CALVIN TRAN
09/18/2025
Special inspection requirement — Interior lighting power
CALVIN TRAN
09/18/2025
Special inspection requirement — Maintenance information
CALVIN TRAN
09/18/2025
Special inspection requirement — Fenestration air leakage
CALVIN TRAN
09/18/2025
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
09/18/2025
Special inspection requirement — Insulation placement and R values
CALVIN TRAN
09/18/2025
Special inspection requirement — Fire-Resistance Rated Construction
CALVIN TRAN
09/18/2025
Special inspection requirement — Fenestration areas
CALVIN TRAN
09/18/2025
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
09/18/2025
Special inspection requirement — Air barrier - visual inspection
CALVIN TRAN
09/18/2025
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
09/18/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
CALVIN TRAN
09/18/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
CALVIN TRAN
09/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Danny Chen
08/26/2025
Permit issued — General Construction
B00839282-I1-GC
10/07/2024
Signed off — Alteration CO
CONVERT EXISITNG 4 DWELLING UNITS INTO 1 FAMILY UNIT WITH INTERIOR WORK AS PER PLANS. OBTAIN NEW C OF O .
B00839282-S2
10/04/2024
Special inspection requirement — Maintenance information
CALVIN TRAN
10/04/2024
Special inspection requirement — Heating Systems
NARESH MAHANGU
10/04/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
10/04/2024
Special inspection requirement — Duct leakage testing, insulation and design
CALVIN TRAN
10/04/2024
Special inspection requirement — Shutoff dampers
CALVIN TRAN
10/04/2024
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
10/04/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
CALVIN TRAN
10/04/2024
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
10/04/2024
Special inspection requirement — Final
CALVIN TRAN
10/04/2024
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
10/04/2024
Special inspection requirement — Mechanical Systems
NARESH MAHANGU
10/03/2024
Filed — Alteration CO
CONVERT EXISITNG 4 DWELLING UNITS INTO 1 FAMILY UNIT WITH INTERIOR WORK AS PER PLANS. OBTAIN NEW C OF O .
B00839282-P4
10/03/2024
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
10/03/2024
Special inspection requirement — Mechanical Systems
NARESH MAHANGU
10/03/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
10/03/2024
Special inspection requirement — Shutoff dampers
CALVIN TRAN
10/03/2024
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
08/22/2024
Signed off — Alteration CO
CONVERT EXISITNG 4 DWELLING UNITS INTO 1 FAMILY UNIT WITH INTERIOR WORK AS PER PLANS. OBTAIN NEW C OF O .
B00839282-S1
07/26/2024
Permit issued — Mechanical Systems
B00839282-S2-MS
05/31/2024
Filed — Alteration CO
CONVERT EXISITNG 4 DWELLING UNITS INTO 1 FAMILY UNIT WITH INTERIOR WORK AS PER PLANS. OBTAIN NEW C OF O .
B00839282-P3
04/10/2024
Violation issued (HPD, closed)
A
03/25/2024
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
03/18/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/23/2024
Filed — Alteration CO
CONVERT EXISITNG 4 DWELLING UNITS INTO 1 FAMILY UNIT WITH INTERIOR WORK AS PER PLANS. OBTAIN NEW C OF O .
B00839282-S2
02/14/2024
Filed — Alteration CO
CONVERT EXISITNG 4 DWELLING UNITS INTO 1 FAMILY UNIT WITH INTERIOR WORK AS PER PLANS. OBTAIN NEW C OF O .
B00839282-P2
02/08/2024
Filed — Alteration CO
CONVERT EXISITNG 4 DWELLING UNITS INTO 1 FAMILY UNIT WITH INTERIOR WORK AS PER PLANS. OBTAIN NEW C OF O .
B00839282-P1
09/28/2023
Permit issued — General Construction
B00839282-I1-GC
07/10/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/10/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/10/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/26/2023
Permit issued — Plumbing
B00839282-S1-PL
05/22/2023
Filed — Alteration
EXISTING 3 STORY BUILDING WITH BASEMENT AND CELLAR, WITH INTERIOR PARTITION WORK. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY.
B08040313-P2
05/17/2023
Filed — Alteration CO
CONVERT EXISITNG 4 DWELLING UNITS INTO 1 FAMILY UNIT WITH INTERIOR WORK AS PER PLANS. OBTAIN NEW C OF O .
B00839282-S1
03/23/2023
Violation issued (HPD, closed)
A
03/15/2023
Filed — Alteration CO
CONVERT EXISITNG 4 DWELLING UNITS INTO 1 FAMILY UNIT WITH INTERIOR WORK AS PER PLANS. OBTAIN NEW C OF O .
B00839282-I1
12/02/2022
Filed — Alteration
EXISTING 3 STORY BUILDING WITH BASEMENT AND CELLAR, WITH INTERIOR PARTITION WORK. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY.
B08040313-P1
11/28/2022
Filed — Alteration
EXISTING 3 STORY BUILDING WITH BASEMENT AND CELLAR, WITH INTERIOR PARTITION WORK. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY.
B08040313-I1
11/14/2022
Violation issued (HPD, closed)
I
02/25/2022
Violation issued (HPD, closed)
A
10/18/2018
Violation issued (HPD, closed)
I
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMORELL BUILDERS INC08/26/2025
DOB NOWMechanical SystemsSigned-offMORELL BUILDERS INC07/26/2024
DOB NOWGeneral ConstructionPermit IssuedMORELL BUILDERS INC09/28/2023
DOB NOWPlumbingSigned-offPLBG P & H INC06/26/2023
1 project · most recent 08/12/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/12/2026Permit IssuedMORELL BUILDERS INCHeating and Air Conditioning Systems
Heat / Cool
Goodman GSXN3N3010 30,000 BTU · Condensing Unit ×3
GSXN3N3610 36,000 BTU · Condensing Unit ×1
1 project · most recent 08/12/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/12/2026Signed-offPLBG P & H INCGas, Storm, Water/Sanitary
1 project · most recent 10/03/2024
General Wiring
FiledStatusContractorScope
10/03/2024CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
06/01/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/25/2024Pass-Final PL - Up to 9 Requested FloorsPassView ↗
03/18/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
07/10/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/10/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/10/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 69
DateRequirementInspectorRole
09/18/2025Duct leakage testing, insulation and designCALVIN TRANenergy_progress
09/18/2025Interior lighting powerCALVIN TRANenergy_progress
09/18/2025HVAC-R and service water heating system controlsCALVIN TRANenergy_progress
09/18/2025HVAC-R and service water piping design and insulationCALVIN TRANenergy_progress
09/18/2025Fenestration areasCALVIN TRANenergy_progress
09/18/2025Fenestration and door U-factor and product ratingsCALVIN TRANenergy_progress
09/18/2025Insulation placement and R valuesCALVIN TRANenergy_progress
09/18/2025Maintenance informationCALVIN TRANenergy_progress
09/18/2025Fire-Resistance Rated ConstructionCALVIN TRANprogress
09/18/2025Energy Code Compliance InspectionsCALVIN TRANprogress
09/18/2025Fire-Resistant Penetrations and JointsDanny Chenspecial
09/18/2025Fenestration air leakageCALVIN TRANenergy_progress
09/18/2025Air barrier - visual inspectionCALVIN TRANenergy_progress
09/18/2025HVAC-R and service water heating equipmentCALVIN TRANenergy_progress
10/04/2024Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
10/04/2024Mechanical SystemsNARESH MAHANGUspecial
10/04/2024Heating SystemsNARESH MAHANGUspecial
10/04/2024FinalCALVIN TRANprogress
10/04/2024Energy Code Compliance InspectionsCALVIN TRANprogress
10/04/2024Duct leakage testing, insulation and designCALVIN TRANenergy_progress
10/04/2024Maintenance informationCALVIN TRANenergy_progress
10/04/2024HVAC-R and service water heating equipmentCALVIN TRANenergy_progress
10/04/2024HVAC-R and service water heating system controlsCALVIN TRANenergy_progress
10/04/2024HVAC-R and service water piping design and insulationCALVIN TRANenergy_progress
10/04/2024Shutoff dampersCALVIN TRANenergy_progress
Latest 25 of 69.
▾Documents — 79 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/28/2026B08040313-I1Request digital key ↗
08/28/2026B08040313-P1Request digital key ↗
08/28/2026B08040313-P2Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits11
▸DOB NOWLPC Approval/Permit11
08/28/2026B08040313-I1Open ↗
08/28/2026B08040313-P1Open ↗
08/25/2026B00839282-P5Open ↗
Showing 3 of 11 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00839282-I1Open ↗
▸Seals & Professional Certifications38
▸DOB NOWProgress Inspector Seal & Signature15
09/06/2026B00839282-P1Open ↗
09/06/2026B00839282-P1Open ↗
09/01/2026B08040313-I1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/06/2026B00839282-P1Open ↗
09/01/2026B08040313-I1Open ↗
08/29/2026B00839282-P3Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/28/2026B08040313-I1Open ↗
08/28/2026B08040313-P1Open ↗
08/25/2026B00839282-P4Open ↗
Showing 3 of 11 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/25/2026B00839282-P5Open ↗
08/13/2026B00839282-P1Open ↗
08/13/2026B00839282-I1Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report11
08/28/2026B08040313-P1Open ↗
08/28/2026B08040313-I1Open ↗
08/25/2026B00839282-S2Open ↗
Showing 3 of 11 on file for this type
▸Other Documents4
▸DOB NOWProperty Ownership Certification3
08/25/2026B00839282-P5Open ↗
08/25/2026B00839282-P1Open ↗
08/25/2026B00839282-I1Open ↗
▸DOB NOWFinal Survey1
08/25/2026B00839282-I1Open ↗